9 research outputs found

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    Irradiation aging of the CMS Drift Tube muon detector

    No full text
    et al.During the High Luminosity LHC, the Drift Tube chambers installed in the CMS detector need to operate with an integrated dose ten times higher than expected at the LHC due to the increase in integrated luminosity from 300 fb-1 to 3000 fb-1. Irradiations have been performed to assess the performance of the detector under such conditions and to characterize the radiation aging of the detector. The presented analysis focuses on the behaviour of the high voltage currents and the dose measurements needed to extrapolate the results to High Luminosity conditions, using data from the photon irradiation campaign at GIF++ in 2016 as well as the efficiency analysis from the irradiation campaign started in 2017. Although the single-wire loss of high voltage gain observed of 70% is very high, the muon reconstruction efficiency is expected to decrease less than 20% during the full duration of High Luminosity LHC in the areas under highest irradiation.Peer reviewe

    Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC

    No full text

    Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC

    No full text
    The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large (similar to O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented

    Irradiation aging of the CMS Drift Tube muon detector

    Get PDF
    During the High Luminosity LHC, the Drift Tube chambers installed in the CMS detector need to operate with an integrated dose ten times higher than expected at the LHC due to the increase in integrated luminosity from 300 fb(-1) to 3000 fb(-1). Irradiations have been performed to assess the performance of the detector under such conditions and to characterize the radiation aging of the detector. The presented analysis focuses on the behaviour of the high voltage currents and the dose measurements needed to extrapolate the results to High Luminosity conditions, using data from the photon irradiation campaign at GIF ++ in 2016 as well as the efficiency analysis from the irradiation campaign started in 2017. Although the single-wire loss of high voltage gain observed of 70% is very high, the muon reconstruction efficiency is expected to decrease less than 20% during the full duration of High Luminosity LHC in the areas under highest irradiation

    The CMS experiment at the CERN LHC

    No full text
    The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t

    The CMS experiment at the CERN LHC

    Get PDF
    0info:eu-repo/semantics/publishe

    CMS physics technical design report: Addendum on high density QCD with heavy ions

    Get PDF
    This report presents the capabilities of the CMS experiment to explore the rich heavy-ion physics programme offered by the CERN Large Hadron Collider (LHC). The collisions of lead nuclei at energies ,will probe quark and gluon matter at unprecedented values of energy density. The prime goal of this research is to study the fundamental theory of the strong interaction - Quantum Chromodynamics (QCD) - in extreme conditions of temperature, density and parton momentum fraction (low-x). This report covers in detail the potential of CMS to carry out a series of representative Pb-Pb measurements. These include "bulk" observables, (charged hadron multiplicity, low pT inclusive hadron identified spectra and elliptic flow) which provide information on the collective properties of the system, as well as perturbative probes such as quarkonia, heavy-quarks, jets and high pT hadrons which yield "tomographic" information of the hottest and densest phases of the reaction.0info:eu-repo/semantics/publishe
    corecore