182 research outputs found
Measurement of the LT-asymmetry in \pi^0 electroproduction at the energy of the \Delta (1232) resonance
The reaction p(e,e'p)pi^0 has been studied at Q^2=0.2 (GeV/c)^2 in the region
of W=1232 MeV. From measurements left and right of q, cross section asymmetries
\rho_LT have been obtained in forward kinematics \rho_LT(\theta_\pi^0=20deg) =
(-11.68 +/- 2.36_stat +/- 2.36_sys)$ and backward kinematics
\rho_LT(\theta_\pi^0=160deg) =(12.18 +/- 0.27_stat +/- 0.82_sys). Multipole
ratios \Re(S_1+^* M_1+)/|M_1+|^2 and \Re(S_0+^* M_1+)/|M_1+|^2 were determined
in the framework of the MAID2003 model. The results are in agreement with older
data. The unusally strong negative \Re(S_0+^* M_1+)/|M_1+|^2 required to bring
also the result of Kalleicher et al. in accordance with the rest of the data is
almost excluded.Comment: 7 pages, 7 figures, 4 tables. Changed content. Accepted for
publication in EPJ
Brain Changes Induced by Electroconvulsive Therapy Are Broadly Distributed
© 2019 Society of Biological Psychiatry Background: Electroconvulsive therapy (ECT) is associated with volumetric enlargements of corticolimbic brain regions. However, the pattern of whole-brain structural alterations following ECT remains unresolved. Here, we examined the longitudinal effects of ECT on global and local variations in gray matter, white matter, and ventricle volumes in patients with major depressive disorder as well as predictors of ECT-related clinical response. Methods: Longitudinal magnetic resonance imaging and clinical data from the Global ECT-MRI Research Collaboration (GEMRIC) were used to investigate changes in white matter, gray matter, and ventricle volumes before and after ECT in 328 patients experiencing a major depressive episode. In addition, 95 nondepressed control subjects were scanned twice. We performed a mega-analysis of single subject data from 14 independent GEMRIC sites. Results: Volumetric increases occurred in 79 of 84 gray matter regions of interest. In total, the cortical volume increased by mean ± SD of 1.04 ± 1.03% (Cohen\u27s d = 1.01, p \u3c .001) and the subcortical gray matter volume increased by 1.47 ± 1.05% (d = 1.40, p \u3c .001) in patients. The subcortical gray matter increase was negatively associated with total ventricle volume (Spearman\u27s rank correlation ρ = −.44, p \u3c .001), while total white matter volume remained unchanged (d = −0.05, p = .41). The changes were modulated by number of ECTs and mode of electrode placements. However, the gray matter volumetric enlargements were not associated with clinical outcome. Conclusions: The findings suggest that ECT induces gray matter volumetric increases that are broadly distributed. However, gross volumetric increases of specific anatomically defined regions may not serve as feasible biomarkers of clinical response
The frequency and outcome of lupus nephritis: results from an international inception cohort study
OBJECTIVE: To determine nephritis outcomes in a prospective multi-ethnic/racial SLE inception cohort. METHODS: Patients in the Systemic Lupus International Collaborating Clinics inception cohort
Shining the light on public attitudes toward laser attacks on aircraft
With increasing incidents being reported, laser attacks present a significant threat to aircraft safety. Although no aircraft accidents have yet been directly attributed to laser attacks to date, experts agree that it is a legitimate threat to safety. To better understand this phenomenon, and ways in which it can be addressed, an important area to understand is the public perception of the severity of such incidents. This would include examining the attitudes the general public hold toward laser attacks, and what views they may hold towards regulation and punishment for these offences. Members of the general public (N=208) completed an online survey that examined their views towards the perceived occurrences and severity of laser attacks, whilst also examining their expectation of criminality and punishment of using a laser against an aircraft. Responses were analysed and presented, with discussion around the nature of public perception and expectation to laser attacks. Mitigations and interventions are explored, focussing on targeted educational/awareness programs that can be used to increase the awareness amongst the general public on the consequences of laser attacks on aircraft
Measurement of D+- and D0 production in deep inelastic scattering using a lifetime tag at HERA
The production of D-+/-- and D-0-mesons has been measured with the ZEUS detector at HERA using an integrated luminosity of 133.6 pb(-1). The measurements cover the kinematic range 5 < Q(2) < 1000 GeV2, 0.02 < y < 0.7, 1.5 < p(T)(D) < 15 GeV and |eta(D)| < 1.6. Combinatorial background to the D-meson signals is reduced by using the ZEUS microvertex detector to reconstruct displaced secondary vertices. Production cross sections are compared with the predictions of next-to-leading-order QCD, which is found to describe the data well. Measurements are extrapolated to the full kinematic phase space in order to obtain the open-charm contribution, F-2(c (c) over bar), to the proton structure function, F-2
Characterizing Deep Brain Stimulation effects in computationally efficient neural network models
The use of income information of census enumeration area as a proxy for the household income in a household survey
<p>Abstract</p> <p>Background</p> <p>Some of the Census Enumeration Areas' (CEA) information may help planning the sample of population studies but it can also be used for some analyses that require information that is more difficult to obtain at the individual or household level, such as income. This paper verifies if the income information of CEA can be used as a proxy for household income in a household survey.</p> <p>Methods</p> <p>A population-based survey conducted from January to December 2003 obtained data from a probabilistic sample of 1,734 households of Niterói, Rio de Janeiro, Brazil. Uniform semi-association models were adjusted in order to obtain information about the agreement/disagreement structure of data. The distribution of nutritional status categories of the population of Niterói according to income quintiles was performed using both CEA- and household-level income measures and then compared using Wald statistics for homogeneity. Body mass index was calculated using body mass and stature data measured in the households and then used to define nutritional status categories according to the World Health Organization. All estimates and statistics were calculated accounting for the structural information of the sample design and a significance level lower than 5% was adopted.</p> <p>Results</p> <p>The classification of households in the quintiles of household income was associated with the classification of these households in the quintiles of CEA income. The distribution of the nutritional status categories in all income quintiles did not differ significantly according to the source of income information (household or CEA) used in the definition of quintiles.</p> <p>Conclusion</p> <p>The structure of agreement/disagreement between quintiles of the household's monthly per capita income and quintiles of the head-of-household's mean nominal monthly income of the CEA, as well as the results produced by these measures when they were associated with the nutritional status of the population, showed that the CEA's income information can be used when income information at the individual or household levels is not available.</p
Advanced Virgo Plus. Future perspectives
While completing the commissioning phase to prepare the Virgo interferometer for the next joint Observation Run (O4), the Virgo collaboration is also finalizing the design of the next upgrades to the detector to be employed in the following Observation Run (O5). The major upgrade will concern decreasing the thermal noise limit, which will imply using very large test masses and increased laser beam size. But this will not be the only upgrade to be implemented in the break between the O4 and O5 observation runs to increase the Virgo detector strain sensitivity. The paper will cover the challenges linked to this upgrade and implications on the detector’s reach and observational potential, reflecting the talk given at 12th Cosmic Ray International Seminar - CRIS 2022 held in September 2022 in Napoli
Higher harmonic anisotropic flow measurements of charged particles in Pb-Pb collisions at 2.76 TeV
We report on the first measurement of the triangular , quadrangular
, and pentagonal charged particle flow in Pb-Pb collisions at 2.76
TeV measured with the ALICE detector at the CERN Large Hadron Collider. We show
that the triangular flow can be described in terms of the initial spatial
anisotropy and its fluctuations, which provides strong constraints on its
origin. In the most central events, where the elliptic flow and
have similar magnitude, a double peaked structure in the two-particle azimuthal
correlations is observed, which is often interpreted as a Mach cone response to
fast partons. We show that this structure can be naturally explained from the
measured anisotropic flow Fourier coefficients.Comment: 10 pages, 4 figures, published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/387
Developmental trajectories of neuroanatomical alterations associated with the 16p11.2 Copy Number Variations
- …
