1,110 research outputs found

    pVir and Bloody Diarrhea in Campylobacter jejuni Enteritis

    Get PDF
    The plasmid pVir may play a role in the virulence of Campylobacter jejuni, a leading cause of bacterial gastroenteritis. The pVir plasmid was identified in 17% of 104 C. jejuni clinical isolates studied and was significantly associated with the occurrence of blood in patient stool, a marker of invasive infection. The pVir plasmid was not associated with greater occurrence of diarrhea, fever, pain, vomiting, or need for patient hospitalization. Isolates containing pVir were also associated with the presence of a tetracycline-resistance plasmid, but pVir did not transfer with tetracycline-resistance plasmids to recipient strains of C. jejuni. The association of pVir and bloody stool suggests that pVir may be clinically relevant in C. jejuni infections

    Spectroscopy detects skeletal muscle microvascular dysfunction during onset of sepsis in a rat fecal peritonitis model

    Get PDF
    Sepsis is a dysregulated host inflammatory response to infection potentially leading to life-threatening organ dysfunction. The objectives of this study were to determine whether early microvascular dysfunction (MVD) in skeletal muscle can be detected as dynamic changes in microvascular hemoglobin (MVHb) levels using spectroscopy and whether MVD precedes organ histopathology in septic peritonitis. Skeletal muscle of male Sprague–Dawley rats was prepared for intravital microscopy. After intraperitoneal injection of fecal slurry or saline, microscopy and spectroscopy recordings were taken for 6 h. Capillary red blood cell (RBC) dynamics and SO2 were quantified from digitized microscopy frames and MVHb levels were derived from spectroscopy data. Capillary RBC dynamics were significantly decreased by 4 h after peritoneal infection and preceded macrohemodynamic changes. At the same time, low-frequency oscillations in MVHb levels exhibited a significant increase in Power in parts of the muscle and resembled oscillations in RBC dynamics and SO2. After completion of microscopy, tissues were collected. Histopathological alterations were not observed in livers, kidneys, brains, or muscles 6 h after induction of peritonitis. The findings of this study show that, in our rat model of sepsis, MVD occurs before detectable organ histopathology and includes ~ 30-s oscillations in MVHb. Our work highlights MVHb oscillations as one of the indicators of MVD onset and provides a foundation for the use of non-invasive spectroscopy to continuously monitor MVD in septic patients

    Cadmium, zinc and iron interactions in the tissues of bank vole Clethrionomys glareolus after exposure to low and high doses of cadmium chloride

    Get PDF
    In present study, bank voles Clethrionomys glareolus were peritioneally injected with different doses of cadmium, 0, 1.5, 3.0 mg Cd/kg body mass. Animals were sacrificed on the 21st day after cadmium exposure and the liver and kidney were obtained for cadmium, zinc and iron analysis using atomic absorption spectrometry. Results showed that cadmium had accumulated in the tissues according to dosage and sex. Cadmium affected the survival and body masses of dosed females. Cadmium decreased the iron concentrations in the liver of voles, whereas zinc concentrations increased in both the kidney and liver

    PHOTOCHEMICAL RING-OPENING IN meso-CHLORINATED CHLOROPHYLLS

    Get PDF
    Irradiation of 20-chloro-chlorophylls of the a-type with visible light produces long-wavelength shifted photoproducts, which transform in the dark to linear tetrapyrroles (bile pigments). The possible significance for chlorophyll degradation is discussed

    KLOE results in kaon physics and prospects for KLOE-2

    Full text link
    The phi-factory DAPHNE offers a possibility to select pure kaon beams, charged and neutral ones. In particular, neutral kaons from phi->KS KL are produced in pairs and the detection of a KS (KL) tags the presence of a KL (KS). This allows to perform precise measurements of kaon properties by means of KLOE detector. Another advantage of a phi-factory consists in fact that the neutral kaon pairs are produced in a pure quantum state (J^(PC) = 1^(--)), which allowsto investigate CP and CPT symmetries via quantum interference effects, as well as the basic principles of quantum mechanics.A review of the most recent results of the KLOE experiment at DAPHNE using pure kaon beams or via quantum interferometry is presented together with prospects for kaon physics at KLOE-2.Comment: 5 pages, 4 figures, From Phi To Psi 2011 conference, to be published in Nuclear Physics B (Proceedings Supplements

    A New Hierarchy of Research Evidence for Tumor Pathology: A Delphi Study to Define Levels of Evidence in Tumor Pathology

    Get PDF
    Copyright \ua9 2023 The Authors. Published by Elsevier Inc. All rights reserved. The hierarchy of evidence is a fundamental concept in evidence-based medicine, but existing models can be challenging to apply in laboratory-based health care disciplines, such as pathology, where the types of evidence and contexts are significantly different from interventional medicine. This project aimed to define a comprehensive and complementary framework of new levels of evidence for evaluating research in tumor pathology-introducing a novel Hierarchy of Research Evidence for Tumor Pathology collaboratively designed by pathologists with help from epidemiologists, public health professionals, oncologists, and scientists, specifically tailored for use by pathologists-and to aid in the production of the World Health Organization Classification of Tumors (WCT) evidence gap maps. To achieve this, we adopted a modified Delphi approach, encompassing iterative online surveys, expert oversight, and external peer review, to establish the criteria for evidence in tumor pathology, determine the optimal structure for the new hierarchy, and ascertain the levels of confidence for each type of evidence. Over a span of 4 months and 3 survey rounds, we collected 1104 survey responses, culminating in a 3-day hybrid meeting in 2023, where a new hierarchy was unanimously agreed upon. The hierarchy is organized into 5 research theme groupings closely aligned with the subheadings of the WCT, and it consists of 5 levels of evidence-level P1 representing evidence types that merit the greatest level of confidence and level P5 reflecting the greatest risk of bias. For the first time, an international collaboration of pathology experts, supported by the International Agency for Research on Cancer, has successfully united to establish a standardized approach for evaluating evidence in tumor pathology. We intend to implement this novel Hierarchy of Research Evidence for Tumor Pathology to map the available evidence, thereby enriching and informing the WCT effectively

    Theory of Pseudomodes in Quantum Optical Processes

    Get PDF
    This paper deals with non-Markovian behaviour in atomic systems coupled to a structured reservoir of quantum EM field modes, with particular relevance to atoms interacting with the field in high Q cavities or photonic band gap materials. In cases such as the former, we show that the pseudo mode theory for single quantum reservoir excitations can be obtained by applying the Fano diagonalisation method to a system in which the atomic transitions are coupled to a discrete set of (cavity) quasimodes, which in turn are coupled to a continuum set of (external) quasimodes with slowly varying coupling constants and continuum mode density. Each pseudomode can be identified with a discrete quasimode, which gives structure to the actual reservoir of true modes via the expressions for the equivalent atom-true mode coupling constants. The quasimode theory enables cases of multiple excitation of the reservoir to now be treated via Markovian master equations for the atom-discrete quasimode system. Applications of the theory to one, two and many discrete quasimodes are made. For a simple photonic band gap model, where the reservoir structure is associated with the true mode density rather than the coupling constants, the single quantum excitation case appears to be equivalent to a case with two discrete quasimodes

    Measurement of the cross-section and charge asymmetry of WW bosons produced in proton-proton collisions at s=8\sqrt{s}=8 TeV with the ATLAS detector

    Get PDF
    This paper presents measurements of the W+μ+νW^+ \rightarrow \mu^+\nu and WμνW^- \rightarrow \mu^-\nu cross-sections and the associated charge asymmetry as a function of the absolute pseudorapidity of the decay muon. The data were collected in proton--proton collisions at a centre-of-mass energy of 8 TeV with the ATLAS experiment at the LHC and correspond to a total integrated luminosity of 20.2~\mbox{fb^{-1}}. The precision of the cross-section measurements varies between 0.8% to 1.5% as a function of the pseudorapidity, excluding the 1.9% uncertainty on the integrated luminosity. The charge asymmetry is measured with an uncertainty between 0.002 and 0.003. The results are compared with predictions based on next-to-next-to-leading-order calculations with various parton distribution functions and have the sensitivity to discriminate between them.Comment: 38 pages in total, author list starting page 22, 5 figures, 4 tables, submitted to EPJC. All figures including auxiliary figures are available at https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/STDM-2017-13

    Search for chargino-neutralino production with mass splittings near the electroweak scale in three-lepton final states in √s=13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for supersymmetry through the pair production of electroweakinos with mass splittings near the electroweak scale and decaying via on-shell W and Z bosons is presented for a three-lepton final state. The analyzed proton-proton collision data taken at a center-of-mass energy of √s=13  TeV were collected between 2015 and 2018 by the ATLAS experiment at the Large Hadron Collider, corresponding to an integrated luminosity of 139  fb−1. A search, emulating the recursive jigsaw reconstruction technique with easily reproducible laboratory-frame variables, is performed. The two excesses observed in the 2015–2016 data recursive jigsaw analysis in the low-mass three-lepton phase space are reproduced. Results with the full data set are in agreement with the Standard Model expectations. They are interpreted to set exclusion limits at the 95% confidence level on simplified models of chargino-neutralino pair production for masses up to 345 GeV
    corecore