414 research outputs found

    Image Quality In Partially Erased Denoptix® Storage Phosphor Plates

    Get PDF
    This study aimed at investigating the effect of the partial erasing of DenOptix® system storage phosphor plates on the image quality of digital radiographs. Standardized digital radiographs were acquired of a phantom mandible, using size 2 intraoral DenOptix® storage phosphor plates (n = 10). Subsequently, the active areas of the plates were placed in a viewing box with a constant light intensity of 1,700 lux for 130 seconds to achieve complete erasing (control plate), as well as for 0, 5, 10, 1S, 20, 25, 34, 66, and 98 seconds, to compose the experimental group of partially erased plates. The same exposure settings were repeated using the control and experimental plates, which were scanned at a resolution of 300 dpi. Five radiologists independently examined the pairs of digital radiographs obtained with the control and partially erased plates, in random order, and indicated the best image for oral diagnosis. Cochran-Mantel-Haenszel's chi-square test, at a significance level of 5%, was used to compare the percentages of superior quality images in each combination of control and partially erased plates, subjectively assessed. No significant differences were found between radiographic images acquired with control and partially erased plates, except for the combination of 0 second (30%) versus 130 seconds (70%), p = 0.0047. It can be concluded that, under adequate light intensity conditions, erasing intraoral DenOptix® storage phosphor plates may require time intervals of as little as 5 seconds.2217883Akdeniz, B.G., Gröndahl, H.G., Kose, T., Effect of delayed scanning of storage phosphor plates (2005) Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 99 (5), pp. 603-607Akdeniz, B.G., Gröndahl, H.G., Degradation of storage phosphor images due to scanning delay (2006) Dentomaxillofac Radiol, 35 (2), pp. 74-77Almeida, S.M., Oliveira, A.E.F., Ferreira, R.I., Bóscolo, F.N., Image quality in digital radiographic systems (2003) Braz Dent J, 14 (2), pp. 136-141Borg, E., Attaelmanan, A., Gröndahl, H.G., Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography (2000) Dentomaxillofac Radiol, 29 (2), pp. 70-75Ferreira, R.I., Haiter-Neto, F., Tabchoury, C.P.M., Paiva, G.A.N., Bóscolo, F.N., Assessment of enamel demineralization using conventional, digital, and digitized radiography (2006) Braz Oral Res, 20 (2), pp. 114-119Wenzel, A., Gröndahl, H.G., Direct digital radiography in the dental office (1995) Int Dent J, 45 (1), pp. 27-34Oliveira, A.E., Almeida, S.M., Paganini, G.A., Haiter Neto, F., Bóscolo, F.N., Comparative study of two digjtal radiographic storage phosphor systems (2000) Braz Dent J, 11 (2), pp. 111-116Borg, E., Attaelmanan, A., Gröndahl, H.G., Image plate systems differ in physical performance (2000) Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 89 (1), pp. 118-124Martins, M.G.B.Q., Haiter Neto, F., Whaites, E.J., Analysis of digital images acquired using different phosphor storage plates (PSPs) subjected to varying reading times and storage conditions (2003) Dentomaxillofac Radiol, 32 (3), pp. 186-190(1998) DenOptix digital imaging system - user manual and installation guide, , Gendex Dental X-Ray Division, Des Plaines: The Division;Menig, J.J., The DenOptix digital radiographic system (1999) J Clin Orthod, 33 (7), pp. 407-410Berkhout WE, Beuger DA, Sanderink GC, van der Stelt PF. The dynamic range of digital radiographic systems: dose reduction or risk of overexposure? Dentomaxillofac Radiol. 2004;33(1):1-SHildebolt, C.F., Couture, R.A., Whiting, B.R., Dental photostimulable phosphor radiography (2000) Dent Clin North Am, 44 (2), pp. 273-297Martins, M.G.B.Q., Whaites, E.J., Ambrosano, G.M.B., Haiter Neto, F., What happens if you delay scanning Digora phosphor storage plates (PSPs) for up to 4 hours? (2006) Dentomaxillofac Radiol, 35 (3), pp. 143-146Gröndahl, H.G., Wenzel, A., Borg, E., Tammisalo, E., An image plate system for digital intra-oral radiography (1996) Dent Update, 23 (8), pp. 334-33

    Diagnosis Of Secondary Caries In Esthetic Restorations: Influence Of The Incidence Vertical Angle Of The X-ray Beam

    Get PDF
    The aim of this study was to evaluate the accuracy on the diagnosis of secondary caries-like lesions simulated on esthetic restorations of different materials, changing the incidence vertical angle (IVA) of the x-ray beam. Twenty human teeth received MOD inlay preparations. In the experimental group (n=10), a round cavity was made in the floor of the proximal box to simulate the caries-like lesion. All teeth were restored with 3 composite resins (Charisma, Filtek-Z250 and TPH-Spectrum) at 3 moments. Two radiographic images were acquired with 0° and 10° IVA. Ten observers evaluated the images using a 5-point confidence scale. Intra- and interobserver reliability was analyzed with the Interclass Correlation Coefficient and the diagnostic accuracy was evaluated using the area under the ROC curve (Az), Friedman test and Wilcoxon test (α=0.05). Higher accuracy values were obtained with 10° IVA (Az=0.66, Filtek- Z250>Az=0.56, TPH-Spectrum) compared to 0° (Az=0.55, Charisma>Az=0.37, TPH-Spectrum), though without statistically significant difference (p>0.05). The detection of secondary caries-like lesions simulated on esthetic restorations of different materials suffered no negative influence by changing the IVA of the x-ray beam.222129133Levin, L., Coval, M., Geiger, S.B., Cross-sectional radiographic survey of amalgam and resin-based composite posterior restorations (2007) Quintessence Int, 38, pp. 511-514Haak, R., Wicht, M.J., Hellmich, M., Noack, M.J., Detection of marginal defects of composite restorations with conventional and digital radiographs (2002) Eur J Oral Sci, 110, pp. 282-286Kirkevang, L.L., Vaeth, M., Wenzel, A., Prevalence and incidence of caries lesions in relation to placement and replacement of fillings: A longitudinal observational radiographic study of an adult Danish population (2009) Caries Res, 43, pp. 286-293Newman, B., Seow, W.K., Kazoullis, S., Ford, D., Holcombe, T., Clinical detection of caries in the primary dentition with and without bitewing radiography (2009) Austr Dent J, 54, pp. 23-30Anbiaee, N., Mohassel, A.R., Imanimoghaddam, M., Moazzami, S.M., A comparison of the accuracy of digital and conventional radiography in the diagnosis of recurrent caries (2010) Contemp Dent Pract, 11, pp. 25-32Nair, M.K., Tyndall, D.A., Ludlow, J.B., May, K., Ye, F., The effects of restorative material and location on the detection of simulated recurrent caries. A comparison of dental film, direct digital radiography and tuned aperture computed tomography (1998) Dentomaxillofac Radiol, 27, pp. 80-84van der Stelt, P.F., Ruttiman, U.E., Webber, R.L., Heemstra, P., In vitro study into the influence from x-ray beam angulation on the detection of artificial caries defects on interproximal radiographs (1989) Caries Res, 23, pp. 334-341Tveit, A.B., Espelid, I., Erickson, R.L., Glasspoole, E.A., Vertical angulation from X-ray beam and radiographic diagnosis of secondary caries (1991) Community Dent Oral Epidemiol, 19, pp. 333-335Akarslan, Z.Z., Akdevelioǧlu, M., Güngör, K., Erten, H., A comparison of the diagnostic accuracy of bitewing, periapical, unfiltered and filtered digital panoramic images for approximal caries detection in posterior teeth (2008) Dentomaxillofac Radiol, 37, pp. 458-463Sabbagh, J., Vreven, J., Leloup, G., Radiopacity of resin-based materials measured in film radiographs and storage phosphor plate (Digora) (2004) Oper Dent, 29, pp. 677-684Dental resin based restorative materials, 6 (10), pp. 1985-1985. , ISO:DP 4049, International standards organization (Draft Proposal), clauseMagalhães, C.S., Freitas, A.B., Moreira, A.N., Ferreira, E.F., Validity of staining and marginal ditching as criteria for diagnosis of secondary caries around occlusal amalgam restorations: An in vitro study (2009) Braz Dent J, 20, pp. 307-313Ergücü, Z., Türkün, L.S., Onem, E., Güneri, P., Comparative radiopacity of six flowable resin composites (2010) Oper Dent, 35, pp. 436-440Lasko, T.A., Bhagwat, J.G., Zou, K.H., Ohno-Machado, L., The use of receiver operating characteristic curves in biomedical informatics (2005) J Biomed Inform, 38, pp. 404-415Diniz, M.B., Rodrigues, J.A., Neuhaus, K.W., Cordeiro, R.C., Lussi, A., Influence of examiner's clinical experience on the reproducibility and accuracy of radiographic examination in detecting occlusal caries (2010) Clin Oral Investig, 14, pp. 515-523Zoellner, A., Diemer, B., Weber, H.P., Stassinakis, A., Gaengler, P., Histologic and radiographic assessment of caries-like lesions localized at the crown margin (2002) J Prosthet Dent, 88, pp. 54-59Ferreira, R.I., Haiter-Neto, F., Tabchoury, C.P., de Paiva, G.A., Bóscolo, F.N., Assessment of enamel demineralization using conventional, digital, and digitized radiography (2006) Braz Oral Res, 20, pp. 114-119Peker, I., Toraman Alkurt, M., Altunkaynak, B., Film tomography compared with film and digital bitewing radiography for proximal caries detection (2007) Dentomaxillofac Radiol, 36, pp. 495-49

    Central Santa Catarina coastal dunefields chronology and their relation to relative sea level and climatic changes

    Get PDF
    During the past decades, there have been contrarian explanations for the formation and stabilization of coastal dunefields: while many authors believe the dunes formation would be enhanced by falling sea level, others argue that a rising or stable sea level context would be favorable. For Brazilian coastal dunefields, the second hypothesis seems to be more consistent with the luminescence ages found so far; however, most of these data were obtained without using the SAR protocol. Another point of concern is the role of climate change in the aeolian system, which is still not very clear. The aim of this paper is to try to clarify these two questions. To this end, five coastal dunefields were selected in central Santa Catarina coast. The remote sensing and dating results allowed the discrimination and mapping of at least four aeolian generations. Their age distribution in relation to the global curve of relative sea level variation during the Late Pleistocene allows us to suggest that the formation of Aeolian dunefields in the coastal context is supported by stable relative sea level. However, relative sea level is not the only determinant for the formation and preservation of the aeolian coastal dunes. Evidences of climatic control indicate that the initiation of dunefields would be favored by periods of less humidity while their stabilization would occur preferably during the periods of rain intensification, connected to monsoon activity

    Soft Dynamics simulation: 2. Elastic spheres undergoing a T1 process in a viscous fluid

    Get PDF
    Robust empirical constitutive laws for granular materials in air or in a viscous fluid have been expressed in terms of timescales based on the dynamics of a single particle. However, some behaviours such as viscosity bifurcation or shear localization, observed also in foams, emulsions, and block copolymer cubic phases, seem to involve other micro-timescales which may be related to the dynamics of local particle reorganizations. In the present work, we consider a T1 process as an example of a rearrangement. Using the Soft dynamics simulation method introduced in the first paper of this series, we describe theoretically and numerically the motion of four elastic spheres in a viscous fluid. Hydrodynamic interactions are described at the level of lubrication (Poiseuille squeezing and Couette shear flow) and the elastic deflection of the particle surface is modeled as Hertzian. The duration of the simulated T1 process can vary substantially as a consequence of minute changes in the initial separations, consistently with predictions. For the first time, a collective behaviour is thus found to depend on another parameter than the typical volume fraction in particles.Comment: 11 pages - 5 figure

    Measurement of the polarisation of W bosons produced with large transverse momentum in pp collisions at sqrt(s) = 7 TeV with the ATLAS experiment

    Get PDF
    This paper describes an analysis of the angular distribution of W->enu and W->munu decays, using data from pp collisions at sqrt(s) = 7 TeV recorded with the ATLAS detector at the LHC in 2010, corresponding to an integrated luminosity of about 35 pb^-1. Using the decay lepton transverse momentum and the missing transverse energy, the W decay angular distribution projected onto the transverse plane is obtained and analysed in terms of helicity fractions f0, fL and fR over two ranges of W transverse momentum (ptw): 35 < ptw < 50 GeV and ptw > 50 GeV. Good agreement is found with theoretical predictions. For ptw > 50 GeV, the values of f0 and fL-fR, averaged over charge and lepton flavour, are measured to be : f0 = 0.127 +/- 0.030 +/- 0.108 and fL-fR = 0.252 +/- 0.017 +/- 0.030, where the first uncertainties are statistical, and the second include all systematic effects.Comment: 19 pages plus author list (34 pages total), 9 figures, 11 tables, revised author list, matches European Journal of Physics C versio

    Observation of a new chi_b state in radiative transitions to Upsilon(1S) and Upsilon(2S) at ATLAS

    Get PDF
    The chi_b(nP) quarkonium states are produced in proton-proton collisions at the Large Hadron Collider (LHC) at sqrt(s) = 7 TeV and recorded by the ATLAS detector. Using a data sample corresponding to an integrated luminosity of 4.4 fb^-1, these states are reconstructed through their radiative decays to Upsilon(1S,2S) with Upsilon->mu+mu-. In addition to the mass peaks corresponding to the decay modes chi_b(1P,2P)->Upsilon(1S)gamma, a new structure centered at a mass of 10.530+/-0.005 (stat.)+/-0.009 (syst.) GeV is also observed, in both the Upsilon(1S)gamma and Upsilon(2S)gamma decay modes. This is interpreted as the chi_b(3P) system.Comment: 5 pages plus author list (18 pages total), 2 figures, 1 table, corrected author list, matches final version in Physical Review Letter

    Search for displaced vertices arising from decays of new heavy particles in 7 TeV pp collisions at ATLAS

    Get PDF
    We present the results of a search for new, heavy particles that decay at a significant distance from their production point into a final state containing charged hadrons in association with a high-momentum muon. The search is conducted in a pp-collision data sample with a center-of-mass energy of 7 TeV and an integrated luminosity of 33 pb^-1 collected in 2010 by the ATLAS detector operating at the Large Hadron Collider. Production of such particles is expected in various scenarios of physics beyond the standard model. We observe no signal and place limits on the production cross-section of supersymmetric particles in an R-parity-violating scenario as a function of the neutralino lifetime. Limits are presented for different squark and neutralino masses, enabling extension of the limits to a variety of other models.Comment: 8 pages plus author list (20 pages total), 8 figures, 1 table, final version to appear in Physics Letters
    corecore