306 research outputs found

    Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with a non-spherical femoral bearing surface

    No full text
    Effective lubrication performance of metal-on-metal hip implants only requires optimum conformity within the main loaded area, while it is advantageous to increase the clearance in the equatorial region. Such a varying clearance can be achieved by using non-spherical bearing surfaces for either acetabular or femoral components. An elastohydrodynamic lubrication model of a novel metal-on-metal hip prosthesis using a non-spherical femoral bearing surface against a spherical cup was solved under loading and motion conditions specified by ISO standard. A full numerical methodology of considering the geometric variation in the rotating non-spherical head in elastohydrodynamic lubrication solution was presented, which is applicable to all non-spherical head designs. The lubrication performance of a hip prosthesis using a specific non-spherical femoral head, Alpharabola, was analysed and compared with those of spherical bearing surfaces and a non-spherical Alpharabola cup investigated in previous studies. The sensitivity of the lubrication performance to the anteversion angle of the Alpharabola head was also investigated. Results showed that the non-spherical head introduced a large squeeze-film action and also led to a large variation in clearance within the loaded area. With the same equatorial clearance, the lubrication performance of the metal-on-metal hip prosthesis using an Alpharabola head was better than that of the conventional spherical bearings but worse than that of the metal-on-metal hip prosthesis using an Alpharabola cup. The reduction in the lubrication performance caused by the initial anteversion angle of the non-spherical head was small, compared with the improvement resulted from the non-spherical geometry

    CARS and SHG microscopy to follow the collagen production in living human corneal fibroblasts and mesenchymal stem cells in fibrin gel 3D cultures

    Full text link
    Coherent anti-Stokes Raman scattering (CARS) microscopy is combined with second harmonic generation (SHG) technique in order to follow the early stage of stem cell differentiation within a 3D scaffold. CARS microscopy can detect lipid membranes and droplet compartments in living cells and SHG microscopy enables a strong imaging contrast for molecules with a non-centrosymmetric ordered structure like collagen. One of the first evidence of hMSCs differentiation is the formation of an extracellular matrix (ECM) where the collagen protein is its main component. This work demonstrated the multimodal CARS and SHG microscopy as a powerful non-invasive label free technique to investigate the collagen production dynamic in living cell 3D cultures. Its ability to image the cell morphology and the produced collagen distribution on a long term (4 weeks) experiment allowed to obtain important information about the cell-scaffold interaction and the ECM production. The very low limit reached in detecting collagen has permitted to map even the small amount of collagen produced by the cells in few hours of culture. This demonstrates multimodal CARS and SHG microscopy as a novel method to follow cells collagen production and cells differentiation process. In addition the experiment shows that the technique is a powerful tool for imaging of very thick sections (about 4 mm). The study conducted on mesenchymal stem cell in fibrin gel cultures confirmed that differentiation stimulus is induced by the scaffold. The monitoring of stem cell differentiation within a scaffold in a non-destructive way will be an important advantage in regenerative medicine and tissue engineering field.Comment: 15 pages, 5 figures, ECONOS 201

    Structural characterisation of hypoxia-mimicking bioactive glasses

    Get PDF
    Nickel and cobalt are both known to stimulate the hypoxia-inducible factor-1 (HIF-1a), thus significantly improving blood vessel formation in tissue engineering applications. We have manufactured nickel and cobalt doped bioactive glasses to act as a controlled delivery mechanism of these ions. The resultant structural consequences have been investigated using the methods of isotopic and isomorphic substitution applied to neutron diffraction. The structural sites present will be intimately related to their release properties in physiological fluids such as plasma and saliva, and hence the bioactivity of the material. Detailed structural knowledge is therefore a prerequisite for optimising material design. Results show that nickel and cobalt adopt a mixed structural role within these bioactive glasses occupying both network-forming (tetrahedral) and network-modifying (5-fold) geometries. Two thirds of the Ni (or Co) occupies a five-fold geometry with the remaining third in a tetrahedral environment. A direct comparison of the primary structural correlations (e.g. Si-O, Ca-O, Na-O and O-Si-O) between the archetypal 45S5 BioglassÂź and the Ni and Co glasses studied here reveal no significant differences. This indicates that the addition of Ni (or Co) will have no adverse effects on the existing structure, and thus on in vitro/in vivo dissolution rates and therefore bioactivity of these glasses

    Spatioselective Modification of Bicompartmental Polymer Particles and Fibers via Huisgen 1,3-Dipolar Cycloaddition

    Full text link
    Precise nano- and microscale control of the architecture of biodegradable biomaterials is desirable for several biotechnological applications such as drug delivery, diagnostics, and medical imaging. Herein, we combine electrohydrodynamic co-jetting and highly specific surface modification (via Huisgen 1,3-dipolar cycloaddition) to prepare particles and fibers with spatioselective surface modification. We first prepared biphasic particles and fibers from commercial poly(lactide- co -glycolide) copolymers via electrohydrodynamic co-jetting of two organic solutions loaded with fluorescent macromolecules and acetylene-modified PLGA derivatives. (i) Spatially controlled reaction of poly[lactide- co -(propargyl glycolide)] with O -(2-aminoethyl)- O â€Č-(2-azidoethyl)heptaethylene glycol and (ii) subsequent conversion of the newly introduced amino groups with fluorescence probes resulted in particles and fibers with surface modification of one hemisphere only.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/61239/1/1655_ftp.pd

    Fabrication of multi-well chips for spheroid cultures and implantable constructs through rapid prototyping techniques

    Get PDF
    Three-dimensional (3D) culture models are widely used in basic and translational research. In this study, to generate and culture multiple 3D cell spheroids, we exploited laser ablation and replica molding for the fabrication of polydimethylsiloxane (PDMS) multi-well chips, which were validated using articular chondrocytes (ACs). Multi-well ACs spheroids were comparable or superior to standard spheroids, as revealed by glycosaminoglycan and type-II collagen deposition. Moreover, the use of our multi-well chips significantly reduced the operation time for cell seeding and medium refresh. Exploiting a similar approach, we used clinical-grade fibrin to generate implantable multi-well constructs allowing for the precise distribution of multiple cell types. Multi-well fibrin constructs were seeded with ACs generating high cell density regions, as shown by histology and cell fluorescent staining. Multi-well constructs were compared to standard constructs with homogeneously distributed ACs. After 7 days in vitro, expression of SOX9, ACAN, COL2A1, and COMP was increased in both constructs, with multi-well constructs expressing significantly higher levels of chondrogenic genes than standard constructs. After 5 weeks in vivo, we found that despite a dramatic size reduction, the cell distribution pattern was maintained and glycosaminoglycan content per wet weight was significantly increased respect to pre-implantation samples. In conclusion, multi-well chips for the generation and culture of multiple cell spheroids can be fabricated by low-cost rapid prototyping techniques. Furthermore, these techniques can be used to generate implantable constructs with defined architecture and controlled cell distribution, allowing for in vitro and in vivo investigation of cell interactions in a 3D environment

    Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis

    Get PDF
    Background and purpose Little is known about the long-term outcome of cemented metal-on-metal hip arthroplasties. We evaluated a consecutive series of metal-on-metal polyethylene-backed cemented hip arthroplasties implanted in patients under 60 years of age

    Biological effects of cobalt-chromium nanoparticles and ions on dural fibroblasts and dural epithelial cells.

    Get PDF
    The introduction of metal-on-metal total disc replacements motivated studies to evaluate the effects of cobalt-chromium (CoCr) nanoparticles on cells of the dura mater. Porcine fibroblasts and epithelial cells isolated from the dura mater were cultured with clinically-relevant CoCr nanoparticles and the ions, generated by the particles over 24 h, at doses up to 121 Όm(3)per cell. Cell viability and production of proinflammatory cytokines was assessed over 4 days. The capacity of the particles to induce oxidative stress in the cells was evaluated at 24 h. The CoCr particles and their ions significantly reduced the viability of the dural epithelial cells in a dose-dependent manner but not the fibroblasts. Both cell types secreted IL-8 in response to particle exposure at doses of 60.5 Όm(3) (epithelial cells) and 121 Όm(3) (fibroblasts, epithelial cells) per cell. No significant release of IL-6 was observed in both cell types at any dose. Reactive oxygen species were induced in both cell types at 50 Όm(3) per cell after 24 h exposure. The data suggested novel differences in the resistance of the dural epithelial cells and fibroblasts to CoCr nanoparticle/ion toxicity and demonstrated the inflammatory potential of the particles. The data contributes to a greater understanding of the potential biological consequences of the use of metal-on-metal total disc prostheses

    Tribofilms on CoCrMo alloys: Understanding the role of the lubricant

    Get PDF
    The tribological activation of a passive metal alloy in an aqueous biological environment have been highlighted by many researchers; better known as bio-tribocorrosion. Tribocorrosion processes, which can be found at a number of metal-based biomedical implant interfaces, can be affected by lubricant species such as proteins, amino acids and salts. To date, researchers have quantified how the presence of organic species and the environment affect the tribological and corrosion process. However, the nature of the bio-films is still broadly to be explored. This study aims to understand how the lubricant - surface interactions influence the evolving frictional, corrosion and material volume loss from CoCrMo alloys and how the formation of any tribo-film at the interface may influence the aforementioned processes. This current research uses reciprocating tribocorrosion tests of CoCrMo surfaces in saline, protein, and protein-free cell culture medium lubricants (0.9% NaCl, 25% Foetal Bovine Serum (FBS) diluted in Phosphate Buffered Saline (PBS), Dulbecco's Modified Eagle Medium (DMEM) and 25% FBS in DMEM solutions). Results show the addition of organic constituents give a better tribology and corrosion performances. XPS confirmed that chemical reactions happened on the tested surfaces. Calcium, phosphorus and sulphur are shown to be catalysed to react in tribology-induced processes and have important roles in tribocorrosion. These results contribute to the understanding of protein-metal interactions occurring in tribofilm formation on wearing surfaces
    • 

    corecore