296 research outputs found

    Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment

    Get PDF
    In this presentation we describe the main design objectives, the detailed specifications and the final layout of the Detector Control System (DCS) for the electromagnetic calorimeter (ECAL) of the CMS experiment. Emphasis is put on the system implementation and specific hardware and software solutions in each of its sub-systems. The latest results from the tests of final prototypes of these subsystems during the 2006 ECAL test-beam programme, as well as the installation and commissioning of the whole DCS at the CMS experimental construction site are discussed

    Detector Control System for the Electromagnetic Calorimeter of the CMS experiment

    Get PDF
    The Compact Muon Solenoid (CMS) is one of the general purpose particle detectors at the Large Hadron Collider (LHC) at CERN. The challenging constraints on the design of one of its sub-detectors, the Electromagnetic Calorimeter (ECAL), required the development of a complex Detector Control System (DCS). In this paper the general features of the CMS ECAL DCS during the period of commissioning and cosmic running will be presented. The feedback from the people involved was used for several upgrades of the system in order to achieve a robust, flexible and stable control system. A description of the newly implemented features for the CMS ECAL DCS subsystems will be given as well

    Maintaining and improving the control and safety systems for the Electromagnetic Calorimeter of the CMS experiment

    Get PDF
    This paper presents the current architecture of the control and safety systems designed and implemented for the Electromagnetic Calorimeter (ECAL) of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC). An evaluation of system performance during all CMS physics data taking periods is reported, with emphasis on how software and hardware solutions are used to overcome limitations, whilst maintaining and improving reliability and robustness. The outcomes of the CMS ECAL Detector Control System (DCS) Software Analysis Project were a fundamental step towards the integration of all control system applications and the consequent piece-by-piece software improvements allowed a smooth transition to the latest revision of the system. The ongoing task of keeping the system in-line with new hardware technologies and software platforms specified by the CMS DCS Group is discussed. The structure of the comprehensive support service with detailed incident logging is presented in addition to a complete test setup for reproducing failures and for testing solutions prior to deployment into production. A correlation between the acquired experience, the development of new software tools and a reduction in the DCS support load is highlighted.International Conference on Computing in High Energy and Nuclear Physics (CHEP), May 21-25, 2012, New York Univ, New York, N

    Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up

    Get PDF
    Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated

    Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered

    Low temperature method for the production of calcium phosphate fillers

    Get PDF
    BACKGROUND: Calcium phosphate manufactured samples, prepared with hydroxyapatite, are used as either spacers or fillers in orthopedic surgery, but these implants have never been used under conditions of mechanical stress. Similar conditions also apply with cements. Many authors have postulated that cements are a useful substitute material when implanted in vivo. The aim of this research is to develop a low cristalline material similar to bone in porosity and cristallinity. METHODS: Commercial hydroxyapatite (HAp) and monetite (M) powders are mixed with water and compacted to produce cylindrical samples. The material is processed at a temperature of 37–120 degrees C in saturated steam to obtain samples that are osteoconductive. The samples are studied by X-ray powder diffraction (XRD), Vickers hardness test (HV), scanning electron microscopy (SEM), and porosity evaluation. RESULTS: The X-ray diffractions of powders from the samples show patterns typical of HAp and M powders. After thermal treatment, no new crystal phase is formed and no increase of the relative intensity of the peaks is obtained. Vicker hardness data do not show any relationship with treatment temperature. The total porosity decreases by 50–60% according to the specific thermal treatment. Scanning electron microscopy of the surfaces of the samples with either HAp 80%-M 20% (c) or Hap 50%-M 50% (f), show cohesion of the powder grains. CONCLUSIONS: The dissolution-reprecipitation process is more intesive in manufactured samples (c) and (f), according to Vickers hardness data. The process occurs in a steam saturated environment between 37 degrees and 120 degrees C. (c) (f) manufactured samples show pore dimension distributions useful to cellular repopulation in living tissues

    Structural changes to resorbable calcium phosphate bioceramic aged <i>in vitro</i>

    Get PDF
    This work investigates the effect of mammalian cell culture conditions on 3D printed calcium phosphate scaffolds. The purpose of the studies presented was to characterise the changes in scaffold properties in physiologically relevant conditions. Differences in crystal morphologies were observed between foetal bovine serum-supplemented media and their unsupplemented analogues, but not for supplemented media containing tenocytes. Scaffold porosity was found to increase for all conditions studied, except for tenocyte-seeded scaffolds. The presence of tenocytes on the scaffold surface inhibited any increase in scaffold porosity in the presence of extracellular matrix secreted by the tenocytes. For acellular conditions the presence or absence of sera proteins strongly affected the rate of dissolution and the distribution of pore diameters within the scaffold. Exposure to high sera protein concentrations led to the development of significant numbers of sub-micron pores, which was otherwise not observed. The implication of these results for cell culture research employing calcium phosphate scaffolds is discussed

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Efeitos adversos do uso contínuo e irracional dos Inibidores de Bomba de Prótons em idosos: Adverse effects of continuous and irrational use of Proton Inhibitors in the elderly

    Get PDF
    O presente trabalho teve por objetivo avaliar os principais efeitos adversos do uso irracional dos Inibidores da Bomba de Prótons (IBPs) na população idosa a fim de compreender as principais alterações geradas no organismo pelo uso habitual dessa classe de medicamentos. Sabe-se que, os avanços tecnológicos e em saúde propiciaram o aumento na qualidade e expectativa de vida da população ao redor do mundo, culminando na elevação exponencial de idosos. Diante disso, com o avanço da idade é comum o aparecimento de patologias, entre elas as gastrointestinais, que têm a sintomatologia tratada por IBPs. Entretanto, estudos evidenciam a relação entre o uso indevido e prolongado de IBPs e prejuízos à saúde dessa população como a ocorrência de lesão renal, hipovitaminose, riscos cardiovasculares e demências. Portanto, é necessária uma avaliação do uso desses fármacos, com o viés de serem indicados apenas com finalidade terapêutica ou profilática, ressaltando a relevância do uso por período recomendado por especialistas. Dito isso, reforça-se a importância do planejamento e da execução de ações que possibilitem o uso apropriado de IBPs, além do desenvolvimento de novas pesquisas que possibilitem a oferta de outros fármacos com o mesmo objetivo terapêutico, porém com menores efeitos adversos

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented
    corecore