415 research outputs found

    The impression creep Monkman Grant relationship

    Get PDF
    Impression creep testing is an established small-scale testing technique in which the indentation rate of a rectangular indenter can be converted into equivalent creep strain rate. It is a versatile technique in that, once a stable indentation rate is established, either the stress, temperature, or both, can be varied to provide data under multiple test conditions on the same specimen. It does not however produce a specimen failure. In order to overcome this limitation, use can be made of an empirical relationship between the creep strain rate obtained in the impression test and the rupture life obtained in a conventional uniaxial creep test at the same stress and temperature. This relationship, termed the Impression Monkman Grant relationship, has been applied successfully to grade 91 steel where it has been shown that rupture life predicted from impression testing is in good agreement with actual rupture life obtained by conventional uniaxial testing. The relationship has proved particularly useful for plant application in situations where mis-heat treated grade 91 pipework with lower than expected creep strength has been encountered, requiring an estimate of creep strength to justify continued operation in service

    Convergence of Discretized Light Cone Quantization in the small mass limit

    Get PDF
    I discuss the slow convergence of Discretized Light Cone Quantization (DLCQ) in the small mass limit and suggest a solution.Comment: 8 pages, 5 Postscript figures, uses boxedeps.te

    Transverse lattice calculation of the pion light-cone wavefunctions

    Get PDF
    We calculate the light-cone wavefunctions of the pion by solving the meson boundstate problem in a coarse transverse lattice gauge theory using DLCQ. A large-N_c approximation is made and the light-cone Hamiltonian expanded in massive dynamical fields at fixed lattice spacing. In contrast to earlier calculations, we include contributions from states containing many gluonic link-fields between the quarks.The Hamiltonian is renormalised by a combination of covariance conditions on boundstates and fitting the physical masses M_rho and M_pi, decay constant f_pi, and the string tension sigma. Good covariance is obtained for the lightest 0^{-+} state, which we identify with the pion. Many observables can be deduced from its light-cone wavefunctions.After perturbative evolution,the quark valence structure function is found to be consistent with the experimental structure function deduced from Drell-Yan pi-nucleon data in the valence region x > 0.5. In addition, the pion distribution amplitude is consistent with the experimental distribution deduced from the pi gamma^* gamma transition form factor and diffractive dissociation. A new observable we calculate is the probability for quark helicity correlation. We find a 45% probability that the valence-quark helicities are aligned in the pion.Comment: 27 pages, 9 figure

    Impression creep test of a P91 steel: a round robin programme

    Get PDF
    The process of standardisation of small specimen creep testing techniques, specifically the impression creep test requires the repeatability of the test method. In this study it is accomplished through a round robin programme involving four different labs which have slightly different test set-ups adhering to predefined recommendations stated in previous work. The labs all conducted the same stepped stress test on a reference heat of grade 91 power plant steel and the displacement traces of the tests are analysed to outline the effects of different test set-ups and their efficacies. Main differences are in temperature control and loading application and control

    Validation of an indirect enzyme-linked immunosorbent assay for the detection of antibody against Brucella abortus in cattle sera using an automated ELISA workstation

    Get PDF
    An automated indirect enzyme-linked immunosorbent assay (I-ELISA) for the serological diagnosis of bovine brucellosis was developed and validated in-house. A total of 4803 cattle sera from South Africa ( n=3 643), Canada ( n=652), Germany ( n=240), France ( n=73) and the USA ( n=195) was used. The South African panel of sera represented 834 sera known to be positive by the Rose Bengal test (RBT), serum agglutination test (SAT) and complement fixation test (CFT), 2709 sera that were negative by CFT and 100 sera from animals vaccinated with a standard dose of Brucella abortus strain 19. Overseas sera were obtained from reference non-vaccinated brucella-free cattle ( n=834), naturally infected ( n=72), experimentally infected ( n=71) and vaccinated animals ( n=83). Also 100 sera collected from cattle in Canada and known to be positive by competitive ELISA (C-ELISA) were used. The intermediate ranges ("borderline" range for the interpretation of test results) were derived from two-graph receiver operating characteristics analysis. The lowest values of the misclassification cost-term analysis obtained from testing overseas panels covered lower I-ELISA cut-off PP values (0.02-3.0) than those from local panels (1.5-5.0). The relatively low cut-off PP values selected for I-ELISA were due to the fact that the positive control used represents a very strong standard compared to other reference positive sera. The greater overlap found between negative and positive cattle sera from South Africa than that between reference overseas panels was probably due to the different criteria used in classifying these panels as negative (sera from true non-diseased/non-infected animals) or positive (sera from true diseased/infected animals). The diagnostic sensitivity of the I-ELISA (at the optimum cutoff value) was 100% and of the CFT 83.3%. The diagnostic specificity of I-ELISA was 99.8% and of the CFT 100%. Estimate of Youden's index was higher for the I-ELISA (0.998) than that for the CFT (0.833). Analysis of distribution of PP values in sera from vaccinated and naturally infected cattle shows that in vaccinated animals all readings were below 31 PP where in infected ones these values represented 43%. Therefore, it appears that I-ELISA could be of use in identifying some naturally infected animals (with values >31 PP) but more sera from reference vaccinated and infected animals need to be tested to further substantiate this statistically. Of 834 sera positive by RBT, SAT and CFT, 825 (98.9%) were positive in the I-ELISA. Compared to C-ELISA the relative diagnostic sensitivity of the I-ELISA was 94% and of the CFT 88% when testing 100 Canadian cattle sera. Of 258 South African cattle sera, of which 183 (70.9%) were positive by the I-ELISA and 148 (57.4%) by the CFT, 197 (76.4%) were positive by C-ELISA when re-tested in Canada. One has to stress, however, that Canadian C-ELISA has not been optimised locally. Thus, the C-ELISA was probably not used at the best diagnostic threshold for testing South African cattle sera. This study shows that the I-ELISA performed on an automated ELISA workstation provides a rapid, simple, highly sensitive and specific diagnostic system for large-scale detection of antibodies against B. abortus. Based on the diagnostic accuracy of this assay reported here, the authors suggest that it could replace not only the currently used confirmatory CFT test, but also the two in-use screening tests, namely the RBT and SAT.The articles have been scanned in colour with a HP Scanjet 5590; 600dpi. Adobe Acrobat v.9 was used to OCR the text and also for the merging and conversion to the final presentation PDF-format.mn201

    ÎČ -decay half-lives of neutron-rich nuclides in the A=100-110 mass region

    Get PDF
    ÎČ-decay half-lives of neutron-rich nuclides in the A=100-110 mass region have been measured using an implantation station installed inside of the Summing NaI(Tl) (SuN) detector at the National Superconducting Cyclotron Laboratory. Accurate half-lives for these nuclides are important for nuclear astrophysics, nuclear structure, and nuclear technology. The half-lives from the present work are compared with previous measurements, showing overall good agreement

    Total absorption spectroscopy of the ÎČ decay of Zr 101,102 and Tc 109

    Get PDF
    20 pags., 9 figs., 5 tabs.The ÎČ decay of Zr101,102 and Tc109 was studied using the technique of total absorption spectroscopy. The experiment was performed at the National Superconducting Cyclotron Laboratory using the Summing NaI(Tl) (SuN) detector in the first-ever application of total absorption spectroscopy with a fast beam produced via projectile fragmentation. The ÎČ-decay feeding intensity and Gamow-Teller transition strength distributions were extracted for these three decays. The extracted distributions were compared to three different quasiparticle random-phase approximation (QRPA) models based on different mean-field potentials. A comparison with calculations from one of the QRPA models was performed to learn about the ground-state shape of the parent nucleus. For Zr101 and Zr102, calculations assuming a pure shape configuration (oblate or prolate) were not able to reproduce the extracted distributions. These results may indicate that some type of mixture between oblate and prolate shapes is necessary to reproduce the extracted distributions. For Tc109, a comparison of the extracted distributions with QRPA calculations suggests a dominant oblate configuration. The other two QRPA models are commonly used to provide ÎČ-decay properties in r-process network calculations. This work shows the importance of making comparisons between the experimental and theoretical ÎČ-decay distributions, rather than just half-lives and ÎČ-delayed neutron emission probabilities, as close to the r-process path as possible.A.A. acknowledges support from the Spanish Ministerio de EconomĂ­a y Competitividad under Grants No. FPA2011-24553, No. FPA2014-52823-C2-1-P, and No. FPA2017-83946-C2-1-P and the program Severo Ochoa (SEV-2014-0398). P.S. acknowledges support from MCIU/AEI/FEDER,UE (Spain) under Contract No. PGC2018-093636-B-I00. S.V. acknowledges support from Czech Science Foundation Project No. 19-14048 and the Charles University Project No. UNCE/SCI/013. This work was supported by the National Science Foundation under Grants No. PHY 1565546 (NSCL), No. PHY 1430152 (JINA-CEE), and No. PHY 1350234 (CAREER). This material is based upon work supported by the Department of Energy National Nuclear Security Administration through the Nuclear Science and Security Consortium under Awards No. DE-NA0003180 and/or No. DE-NA000097

    A potent and selective Sirtuin 1 inhibitor alleviates pathology in multiple animal and cell models of Huntington's disease

    Get PDF
    Protein acetylation, which is central to transcriptional control as well as other cellular processes, is disrupted in Huntington's disease (HD). Treatments that restore global acetylation levels, such as inhibiting histone deacetylases (HDACs), are effective in suppressing HD pathology in model organisms. However, agents that selectively target the disease-relevant HDACs have not been available. SirT1 (Sir2 in Drosophila melanogaster) deacetylates histones and other proteins including transcription factors. Genetically reducing, but not eliminating, Sir2 has been shown to suppress HD pathology in model organisms. To date, small molecule inhibitors of sirtuins have exhibited low potency and unattractive pharmacological and biopharmaceutical properties. Here, we show that highly selective pharmacological inhibition of Drosophila Sir2 and mammalian SirT1 using the novel inhibitor selisistat (selisistat; 6-chloro-2,3,4,9-tetrahydro-1H-carbazole-1-carboxamide) can suppress HD pathology caused by mutant huntingtin exon 1 fragments in Drosophila, mammalian cells and mice. We have validated Sir2 as the in vivo target of selisistat by showing that genetic elimination of Sir2 eradicates the effect of this inhibitor in Drosophila. The specificity of selisistat is shown by its effect on recombinant sirtuins in mammalian cells. Reduction of HD pathology by selisistat in Drosophila, mammalian cells and mouse models of HD suggests that this inhibitor has potential as an effective therapeutic treatment for human disease and may also serve as a tool to better understand the downstream pathways of SirT1/Sir2 that may be critical for H

    Measurement of the polarisation of W bosons produced with large transverse momentum in pp collisions at sqrt(s) = 7 TeV with the ATLAS experiment

    Get PDF
    This paper describes an analysis of the angular distribution of W->enu and W->munu decays, using data from pp collisions at sqrt(s) = 7 TeV recorded with the ATLAS detector at the LHC in 2010, corresponding to an integrated luminosity of about 35 pb^-1. Using the decay lepton transverse momentum and the missing transverse energy, the W decay angular distribution projected onto the transverse plane is obtained and analysed in terms of helicity fractions f0, fL and fR over two ranges of W transverse momentum (ptw): 35 < ptw < 50 GeV and ptw > 50 GeV. Good agreement is found with theoretical predictions. For ptw > 50 GeV, the values of f0 and fL-fR, averaged over charge and lepton flavour, are measured to be : f0 = 0.127 +/- 0.030 +/- 0.108 and fL-fR = 0.252 +/- 0.017 +/- 0.030, where the first uncertainties are statistical, and the second include all systematic effects.Comment: 19 pages plus author list (34 pages total), 9 figures, 11 tables, revised author list, matches European Journal of Physics C versio
    • 

    corecore