3,193 research outputs found

    The CMS Silicon Strip Tracker performance using cosmic ray data

    Get PDF
    The CMS Silicon Strip Tracker is the largest tracking system based on silicon detector technology ever built for high energy physics experiment. It consists of 24,244 single-sided micro-strip sensors for a total active area of 198 m2m^2 and about 10 million readout channels. The SST was installed inside CMS in December 2007, commissioned during summer 2008 and then it participated along with other CMS subdetectors in several cosmic muon data taking runs. The commissioning strategy, operational experience and detector performance results will be presented

    Targeting of RET oncogene by naphthalene diimide-mediated gene promoter G-quadruplex stabilization exerts anti-tumor activity in oncogene-addicted human medullary thyroid cancer

    Get PDF
    Medullary thyroid cancer (MTC) relies on the aberrant activation of RET proto-oncogene. Though targeted approaches (i.e., tyrosine kinase inhibitors) are available, the absence of complete responses and the onset of resistance mechanisms indicate the need for novel therapeutic interventions. Due to their role in regulation of gene expression, G-quadruplexes (G4) represent attractive targets amenable to be recognized or stabilized by small molecules. Here, we report that exposure of MTC cells to a tri-substituted naphthalene diimide (NDI) resulted in a significant antiproliferative activity paralleled by inhibition of RET expression. Biophysical analysis and gene reporter assays showed that impairment of RET expression was consequent to the NDI-mediated stabilization of the G4 forming within the gene promoter. We also showed for the first time that systemic administration of the NDI in mice xenotransplanted with MTC cells resulted in a remarkable inhibition of tumor growth in vivo. Overall, our findings indicate that NDI-dependent RET G4 stabilization represents a suitable approach to control RET transcription and delineate the rationale for the development of G4 stabilizing-based treatments for MTC as well as for other tumors in which RET may have functional and therapeutic implications

    Phosphonated Carbocyclic 2'-Oxa-3'-azanucleosides as New Antiretroviral Agents

    Get PDF
    Phosphonated carbocyclic 2¢-oxa-3¢-azanucleosides have been synthesized and tested for their antiretroviral activity. The obtained results have shown that some of the compounds were as powerful as azydothymidine in inhibiting the reverse transcriptase activity of the human retrovirus T-cell leukemia/lymphotropic virus type 1 and in protecting human peripheral blood mononuclear cells against human retrovirus T-cell leukemia/ lymphotropic virus type 1 transmission in vitro. These data indicate that phosphonated carbocyclic 2¢-oxa- 3¢-azanucleosides possess the necessary requirements to efficiently counteract infections caused by human retroviruses

    The Data Quality Monitoring for the CMS Silicon Strip Tracker

    Get PDF
    The CMS Silicon Strip Tracker (SST), consisting of more than 10 million channels, is organized in about 15,000 detector modules and it is the largest silicon strip tracker ever built for high energy physics experiments. The Data Quality Monitoring system for the Tracker has been developed within the CMS Software framework. More than 100,000 monitorable quantities need to be managed by the DQM system that organizes them in a hierarchical structure reflecting the detector arrangement in subcomponents and the various levels of data processing. Monitorable quantities computed at the level of individual detectors are processed to extract automatic quality checks and summary results that can be visualized with specialized graphical user interfaces. In view of the great complexity of the CMS Tracker detector the standard visualization tools based on histograms have been complemented with 2 and 3 dimensional graphical images of the subdetector that can show the whole detector down to single channel resolution. The functionalities of the CMS Silicon Strip Tracker DQM system and the experience acquired during the SST commissioning will be described

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE

    Combined search for the quarks of a sequential fourth generation

    Get PDF
    Results are presented from a search for a fourth generation of quarks produced singly or in pairs in a data set corresponding to an integrated luminosity of 5 inverse femtobarns recorded by the CMS experiment at the LHC in 2011. A novel strategy has been developed for a combined search for quarks of the up and down type in decay channels with at least one isolated muon or electron. Limits on the mass of the fourth-generation quarks and the relevant Cabibbo-Kobayashi-Maskawa matrix elements are derived in the context of a simple extension of the standard model with a sequential fourth generation of fermions. The existence of mass-degenerate fourth-generation quarks with masses below 685 GeV is excluded at 95% confidence level for minimal off-diagonal mixing between the third- and the fourth-generation quarks. With a mass difference of 25 GeV between the quark masses, the obtained limit on the masses of the fourth-generation quarks shifts by about +/- 20 GeV. These results significantly reduce the allowed parameter space for a fourth generation of fermions.Comment: Replaced with published version. Added journal reference and DO

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Can C\u3csub\u3eP\u3c/sub\u3e Be Less Than C\u3csub\u3eV\u3c/sub\u3e?

    Get PDF
    Can CP be less than CV? This is a fundamental question in physics, chemistry, chemical engineering, and mechanical engineering. This question hangs in the minds of many students, instructors, and researchers. The first instinct is to answer “Yes, for water between 0 and 4 °C” if one knows that water expands as temperature decreases in this temperature range. The same question is asked in several Physical Chemistry and Physics textbooks. Students are supposed to answer that water contracts when heated at below 4 °C in an isobaric process. Because work is done to the contracting water, less heat is required to increase the water temperature in an isobaric process than in an isochoric process. Therefore, CP is less than CV. However, this answer is fundamentally flawed because it assumes, implicitly and incorrectly, that the internal energy change of water depends solely on its temperature change. Neglecting the variation of the internal energy with volume (internal pressure) will invalidate the Clausius inequality and violate the second law of thermodynamics. Once the internal pressure is properly taken into account, it becomes clear that CP cannot be less than CV for any substance at any temperature regardless of the sign of the thermal expansion coefficient of the substance

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
    corecore