197 research outputs found

    Spatial antibunching of photons with parametric down-conversion

    Full text link
    The theoretical framework behind a recent experiment by Nogueira et. al. [Phys. Rev. Lett. 86}, 4009 (2001)] of spatial antibunching in a two-photon state generated by collinear type II parametric down-conversion and a birefringent double-slit is presented. The fourth-order quantum correlation function is evaluated and shown to violate the classical Schwarz-type inequality, ensuring that the field does not have a classical analog. We expect these results to be useful in the rapidly growing fields of quantum imaging and quantum information.Comment: 5 pages, 3 figures. Minor changes made, accepted for publication in PR

    Atmospheric effects on extensive air showers observed with the Surface Detector of the Pierre Auger Observatory

    Get PDF
    Atmospheric parameters, such as pressure (P), temperature (T) and density, affect the development of extensive air showers initiated by energetic cosmic rays. We have studied the impact of atmospheric variations on extensive air showers by means of the surface detector of the Pierre Auger Observatory. The rate of events shows a ~10% seasonal modulation and ~2% diurnal one. We find that the observed behaviour is explained by a model including the effects associated with the variations of pressure and density. The former affects the longitudinal development of air showers while the latter influences the Moliere radius and hence the lateral distribution of the shower particles. The model is validated with full simulations of extensive air showers using atmospheric profiles measured at the site of the Pierre Auger Observatory.Comment: 24 pages, 9 figures, accepted for publication in Astroparticle Physic

    Update on the correlation of the highest energy cosmic rays with nearby extragalactic matter

    Get PDF
    Data collected by the Pierre Auger Observatory through 31 August 2007 showed evidence for anisotropy in the arrival directions of cosmic rays above the Greisen-Zatsepin-Kuz'min energy threshold, \nobreak{6×10196\times 10^{19}eV}. The anisotropy was measured by the fraction of arrival directions that are less than 3.13.1^\circ from the position of an active galactic nucleus within 75 Mpc (using the V\'eron-Cetty and V\'eron 12th12^{\rm th} catalog). An updated measurement of this fraction is reported here using the arrival directions of cosmic rays recorded above the same energy threshold through 31 December 2009. The number of arrival directions has increased from 27 to 69, allowing a more precise measurement. The correlating fraction is (386+7)(38^{+7}_{-6})%, compared with 2121% expected for isotropic cosmic rays. This is down from the early estimate of (6913+11)(69^{+11}_{-13})%. The enlarged set of arrival directions is examined also in relation to other populations of nearby extragalactic objects: galaxies in the 2 Microns All Sky Survey and active galactic nuclei detected in hard X-rays by the Swift Burst Alert Telescope. A celestial region around the position of the radiogalaxy Cen A has the largest excess of arrival directions relative to isotropic expectations. The 2-point autocorrelation function is shown for the enlarged set of arrival directions and compared to the isotropic expectation.Comment: Accepted for publication in Astroparticle Physics on 31 August 201

    The Fluorescence Detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.Comment: 53 pages. Submitted to Nuclear Instruments and Methods in Physics Research Section

    Elaboração da composição centesimal e avaliação da estabilidade oxidativa de hambúrgueres de tilápia-do-nilo (Oreochromis niloticus Linnaeus, 1758), adicionados de carotenóides de Bixa orellana L.

    Get PDF
    Os experimentos avaliaram a atividade antioxidante dos carotenóides obtidos do urucum (bixina enorbixina) em hambúrguer processado à base de tiláipia, tendo como base para comparação de eficiênciao eritorbato de sódio, antioxidante utilizado largamente na indústria de processamento de carne e comobase para o efeito antioxidante a amostra controle (sem utilização de antioxidante). Os carotenoides, bemcomo o eritorbato de sódio, foram utilizados em igual concentração no produto (0,05%), a fim deestabelecer um parâmetro de igualdade para a comparação. Os resultados obtidos mostraram que houvediferença significativa, em nível de 5%, entre as amostras de bixina e norbixina em comparação comeritorbato de sódio para o controle da oxidação lipídica, medido a partir da formação de malonaldodeído eexpresso em mg/Kg de produto, no período de nove dias de estocagem sob temperatura de 80C , commelhor desempenho por parte do eritorbato de sódio. As estruturas de bixina e norbixina nãoapresentaram diferença significativa em comparação direta entre elas, em nível de 5 %, e apresentaramdiferença significativa em comparação com a amostra controle, levando ao resultado positivo para ocontrole da oxidação lipídica

    Search for First Harmonic Modulation in the Right Ascension Distribution of Cosmic Rays Detected at the Pierre Auger Observatory

    Get PDF
    We present the results of searches for dipolar-type anisotropies in different energy ranges above 2.5×10172.5\times 10^{17} eV with the surface detector array of the Pierre Auger Observatory, reporting on both the phase and the amplitude measurements of the first harmonic modulation in the right-ascension distribution. Upper limits on the amplitudes are obtained, which provide the most stringent bounds at present, being below 2% at 99% C.L.C.L. for EeV energies. We also compare our results to those of previous experiments as well as with some theoretical expectations.Comment: 28 pages, 11 figure

    Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18) eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Cross checks between the two methods demonstrate that results from both analyses are compatible, and that the uncertainties are well understood. The measurements of the aerosol attenuation provided by the two procedures are currently used at the Pierre Auger Observatory to reconstruct air shower data

    The rapid atmospheric monitoring system of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a facility built to detect air showers produced by cosmic rays above 10(17) eV. During clear nights with a low illuminated moon fraction, the UV fluorescence light produced by air showers is recorded by optical telescopes at the Observatory. To correct the observations for variations in atmospheric conditions, atmospheric monitoring is performed at regular intervals ranging from several minutes (for cloud identification) to several hours (for aerosol conditions) to several days (for vertical profiles of temperature, pressure, and humidity). In 2009, the monitoring program was upgraded to allow for additional targeted measurements of atmospheric conditions shortly after the detection of air showers of special interest, e. g., showers produced by very high-energy cosmic rays or showers with atypical longitudinal profiles. The former events are of particular importance for the determination of the energy scale of the Observatory, and the latter are characteristic of unusual air shower physics or exotic primary particle types. The purpose of targeted (or 'rapid') monitoring is to improve the resolution of the atmospheric measurements for such events. In this paper, we report on the implementation of the rapid monitoring program and its current status. The rapid monitoring data have been analyzed and applied to the reconstruction of air showers of high interest, and indicate that the air fluorescence measurements affected by clouds and aerosols are effectively corrected using measurements from the regular atmospheric monitoring program. We find that the rapid monitoring program has potential for supporting dedicated physics analyses beyond the standard event reconstruction

    Modeling and optimization of sensory changes and shelf-life in vacuum-packaged cooked ham treated by E-beam irradiation

    Full text link
    [EN] The E-beam irradiation of vacuum-packaged RTE cooked ham was carried out to establish the dose required to achieve the food safety objective (FSO) and to minimize changes in selected sensory attributes. Cooked ham was irradiated with doses ranging 1-4 kGy. After the treatment, the microbial inactivation of Listeria monocytogenes, the shelf-life of the product and some sensory attributes (appearance, odor, and flavor) were determined. The inactivation of L monocytogenes was satisfactorily described by a first-order kinetics equation (R2=0.99). The influence of the irradiation dose on appearance, odor, and flavor was modeled through Gompertz (R2=0.99, for appearance) and Activation/Inactivation (R2=0.99, for odor and flavor) equations. A model was also developed to determine the shelf-life of irradiated cooked ham depending on the irradiation dose (R2 > 0.91). The dose that maximized the scores of the sensory attributes was 0.96 kGy resulting in an acceptable sensory quality for 80 days. It is possible to apply up to 2 kGy to ensure microbial safety, while provoking no significant changes in the above mentioned sensory attributes. (C) 2010 Elsevier Ltd. All rights reserved.The authors acknowledge the financial support from the Project CSD2007-00016 (CONSOLIDER-INGENIO 2010) funded by the Spanish Ministry of Science and Innovation.Benedito Fort, JJ.; Cambero, MI.; Ortuño Cases, C.; Cabeza, MC.; Ordoñez, JA.; De La Hoz, L. (2011). Modeling and optimization of sensory changes and shelf-life in vacuum-packaged cooked ham treated by E-beam irradiation. Radiation Physics and Chemistry. 80(3):505-513. https://doi.org/10.1016/j.radphyschem.2010.11.001S50551380
    corecore