617 research outputs found

    Analysis of Extended Threshold Wavelength Photoresponse in Nonsymmetrical p-GaAs/AlGaAs Heterostructure Photodetectors

    Get PDF
    We analyze the extended threshold wavelength photoresponse beyond the standard threshold limit (λt = 1.24/Δ, where Δ is the activation energy) in nonsymmetrical pGaAs/AlGaAs heterostructure photodetectors with a barrier energy offset. We propose that hot-cold hole carrier interactions in the p-GaAs absorber are responsible for the threshold wavelength extension. Experimental results are analyzed by considering a quasi-Fermi distribution of hot holes at a hot hole temperature (TH), which is much higher than the lattice temperature (TL). The experimental photoresponse is fitted using an escape cone model, modified with a quasi-Fermi level (EquasiF). The simulated results are found to be in good agreement with experimental data, justifying the model used

    Photoelectrochemical properties of mesoporous NiOx deposited on technical FTO via nanopowder sintering in conventional and plasma atmospheres

    Get PDF
    Nanoporous nickel oxide (NiO x ) has been deposited with two different procedures of sintering (CS and RDS). Both samples display solid state oxidation at about 3.1 V vs Li+/Li. Upon sensitization of CS/RDS NiO x with erythrosine b (ERY), nickel oxide oxidation occurs at the same potential. Impedance spectroscopy revealed a higher charge transfer resistance for ERY-sensitized RDS NiO x with respect to sensitized CS NiO x . This was due to the chemisorption of a larger amount of ERY on RDS with respect to CS NiO x . Upon illumination the photoinduced charge transfer between ERY layer and NiO x could be observed only with oxidized CS. Photoelectrochemical effects of sensitized RDS NiO x were evidenced upon oxide reduction. With the addition of iodine RDS NiOx electrodes could give the reduction iodine → iodide in addition to the reduction of RDS NiO x . p-type dye sensitized solar cells were assembled with RDS NiO x photocathodes sensitized either by ERY or Fast Green. Resulting overall efficiencies ranged between 0.02 and 0.04 % upon irradiation with solar spectrum simulator (Iin : 0.1 W cm −2 )

    Monitoring of water quality in a shrimp farm using a FANET

    Get PDF
    This paper develops an architecture for flying ad-hoc networks (FANETs) to enable monitoring of water quality in a shrimp farm. Firstly, the key monitoring parameters for the characterization of water quality are highlighted and their desired operational ranges are summarized. These parameters directly influence shrimp survival and healthy growth. Based on the considered sensing modality, a reference architecture for implementing a cost-effective FANET based mobile sensing platform is developed. The controlled mobility of the platform is harnessed to increase the spatial monitoring resolution without the need for extensive infrastructure deployment. The proposed solution will be offered to shrimp farmers in the Mexican state of Colima once the laboratory trials are concluded

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Compressed representation of a partially defined integer function over multiple arguments

    Get PDF
    In OLAP (OnLine Analitical Processing) data are analysed in an n-dimensional cube. The cube may be represented as a partially defined function over n arguments. Considering that often the function is not defined everywhere, we ask: is there a known way of representing the function or the points in which it is defined, in a more compact manner than the trivial one

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Prevalence of gastro-oesophageal reflux disease symptoms and reflux-associated respiratory symptoms in asthma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Gastro-oesophageal reflux disease (GORD) symptoms are common in asthma and have been extensively studied, but less so in the Asian continent. Reflux-associated respiratory symptoms (RARS) have, in contrast, been little-studied globally. We report the prevalence of GORD symptoms and RARS in adult asthmatics, and their association with asthma severity and medication use.</p> <p>Methods</p> <p>A cross-sectional analytical study. A validated interviewer-administered GORD scale was used to assess frequency and severity of seven GORD symptoms. Subjects were consecutive asthmatics attending medical clinics. Controls were matched subjects without respiratory symptoms.</p> <p>Results</p> <p>The mean (SD) composite GORD symptom score of asthmatics was significantly higher than controls (21.8 (17.2) versus 12.0 (7.6); <it>P </it>< 0.001) as was frequency of each symptom and RARS. Prevalence of GORD symptoms in asthmatics was 59.4% (95% CI, 59.1%-59.6%) versus 28.5% in controls (95% CI, 29.0% - 29.4%). 36% of asthmatics experienced respiratory symptoms in association with both typical and atypical GORD symptoms, compared to 10% of controls (<it>P </it>< 0.001). An asthmatic had a 3.5 times higher risk of experiencing a GORD symptom after adjusting for confounders (OR 3.5; 95% CI 2.5-5.3). Severity of asthma had a strong dose-response relationship with GORD symptoms. Asthma medication use did not significantly influence the presence of GORD symptoms.</p> <p>Conclusions</p> <p>GORD symptoms and RARS were more prevalent in a cohort of Sri Lankan adult asthmatics compared to non-asthmatics. Increased prevalence of RARS is associated with both typical and atypical symptoms of GORD. Asthma disease and its severity, but not asthma medication, appear to influence presence of GORD symptoms.</p
    corecore