1,354 research outputs found

    The listening talker: A review of human and algorithmic context-induced modifications of speech

    Get PDF
    International audienceSpeech output technology is finding widespread application, including in scenarios where intelligibility might be compromised - at least for some listeners - by adverse conditions. Unlike most current algorithms, talkers continually adapt their speech patterns as a response to the immediate context of spoken communication, where the type of interlocutor and the environment are the dominant situational factors influencing speech production. Observations of talker behaviour can motivate the design of more robust speech output algorithms. Starting with a listener-oriented categorisation of possible goals for speech modification, this review article summarises the extensive set of behavioural findings related to human speech modification, identifies which factors appear to be beneficial, and goes on to examine previous computational attempts to improve intelligibility in noise. The review concludes by tabulating 46 speech modifications, many of which have yet to be perceptually or algorithmically evaluated. Consequently, the review provides a roadmap for future work in improving the robustness of speech output

    Spectrogram inversion and potential applications for hearing research

    Get PDF

    Methods of Optimizing Speech Enhancement for Hearing Applications

    Get PDF
    Speech intelligibility in hearing applications suffers from background noise. One of the most effective solutions is to develop speech enhancement algorithms based on the biological traits of the auditory system. In humans, the medial olivocochlear (MOC) reflex, which is an auditory neural feedback loop, increases signal-in-noise detection by suppressing cochlear response to noise. The time constant is one of the key attributes of the MOC reflex as it regulates the variation of suppression over time. Different time constants have been measured in nonhuman mammalian and human auditory systems. Physiological studies reported that the time constant of nonhuman mammalian MOC reflex varies with the properties (e.g. frequency, bandwidth) changes of the stimulation. A human based study suggests that time constant could vary when the bandwidth of the noise is changed. Previous works have developed MOC reflex models and successfully demonstrated the benefits of simulating the MOC reflex for speech-in-noise recognition. However, they often used fixed time constants. The effect of the different time constants on speech perception remains unclear. The main objectives of the present study are (1) to study the effect of the MOC reflex time constant on speech perception in different noise conditions; (2) to develop a speech enhancement algorithm with dynamic time constant optimization to adapt to varying noise conditions for improving speech intelligibility. The first part of this thesis studies the effect of the MOC reflex time constants on speech-in-noise perception. Conventional studies do not consider the relationship between the time constants and speech perception as it is difficult to measure the speech intelligibility changes due to varying time constants in human subjects. We use a model to investigate the relationship by incorporating Meddis’ peripheral auditory model (which includes a MOC reflex) with an automatic speech recognition (ASR) system. The effect of the MOC reflex time constant is studied by adjusting the time constant parameter of the model and testing the speech recognition accuracy of the ASR. Different time constants derived from human data are evaluated in both speech-like and non-speech like noise at the SNR levels from -10 dB to 20 dB and clean speech condition. The results show that the long time constants (≥1000 ms) provide a greater improvement of speech recognition accuracy at SNR levels≤10 dB. Maximum accuracy improvement of 40% (compared to no MOC condition) is shown in pink noise at the SNR of 10 dB. Short time constants (<1000 ms) show recognition accuracy over 5% higher than the longer ones at SNR levels ≥15 dB. The second part of the thesis develops a novel speech enhancement algorithm based on the MOC reflex with a time constant that is dynamically optimized, according to a lookup table for varying SNRs. The main contributions of this part include: (1) So far, the existing SNR estimation methods are challenged in cases of low SNR, nonstationary noise, and computational complexity. High computational complexity would increase processing delay that causes intelligibility degradation. A variance of spectral entropy (VSE) based SNR estimation method is developed as entropy based features have been shown to be more robust in the cases of low SNR and nonstationary noise. The SNR is estimated according to the estimated VSE-SNR relationship functions by measuring VSE of noisy speech. Our proposed method has an accuracy of 5 dB higher than other methods especially in the babble noise with fewer talkers (2 talkers) and low SNR levels (< 0 dB), with averaging processing time only about 30% of the noise power estimation based method. The proposed SNR estimation method is further improved by implementing a nonlinear filter-bank. The compression of the nonlinear filter-bank is shown to increase the stability of the relationship functions. As a result, the accuracy is improved by up to 2 dB in all types of tested noise. (2) A modification of Meddis’ MOC reflex model with a time constant dynamically optimized against varying SNRs is developed. The model incudes simulated inner hair cell response to reduce the model complexity, and now includes the SNR estimation method. Previous MOC reflex models often have fixed time constants that do not adapt to varying noise conditions, whilst our modified MOC reflex model has a time constant dynamically optimized according to the estimated SNRs. The results show a speech recognition accuracy of 8 % higher than the model using a fixed time constant of 2000 ms in different types of noise. (3) A speech enhancement algorithm is developed based on the modified MOC reflex model and implemented in an existing hearing aid system. The performance is evaluated by measuring the objective speech intelligibility metric of processed noisy speech. In different types of noise, the proposed algorithm increases intelligibility at least 20% in comparison to unprocessed noisy speech at SNRs between 0 dB and 20 dB, and over 15 % in comparison to processed noisy speech using the original MOC based algorithm in the hearing aid

    Effects of Coordinated Bilateral Hearing Aids and Auditory Training on Sound Localization

    Get PDF
    This thesis has two main objectives: 1) evaluating the benefits of the bilateral coordination of the hearing aid Digital Signal Processing (DSP) features by measuring and comparing the auditory performance with and without the activation of this coordination, and 2) evaluating the benefits of acclimatization and auditory training on such auditory performance and, determining whether receiving training in one aspect of auditory performance (sound localization) would generalize to an improvement in another aspect of auditory performance (speech intelligibility in noise), and to what extent. Two studies were performed. The first study evaluated the speech intelligibility in noise and horizontal sound localization abilities in HI listeners using hearing aids that apply bilateral coordination of WDRC. A significant improvement was noted in sound localization with bilateral coordination on when compared to off, while speech intelligibility in noise did not seem to be affected. The second study was an extension of the first study, with a suitable period for acclimatization provided and then the participants were divided into training and control groups. Only the training group received auditory training. The training group performance was significantly better than the control group performance in some conditions, in both the speech intelligibility and the localization tasks. The bilateral coordination did not have significant effects on the results of the second study. This work is among the early literature to investigate the impact of bilateral coordination in hearing aids on the users’ auditory performance. Also, this work is the first to demonstrate the effect of auditory training in sound localization on the speech intelligibility performance

    Minimum Processing Near-end Listening Enhancement

    Full text link
    The intelligibility and quality of speech from a mobile phone or public announcement system are often affected by background noise in the listening environment. By pre-processing the speech signal it is possible to improve the speech intelligibility and quality -- this is known as near-end listening enhancement (NLE). Although, existing NLE techniques are able to greatly increase intelligibility in harsh noise environments, in favorable noise conditions the intelligibility of speech reaches a ceiling where it cannot be further enhanced. Actually, the focus of existing methods solely on improving the intelligibility causes unnecessary processing of the speech signal and leads to speech distortions and quality degradations. In this paper, we provide a new rationale for NLE, where the target speech is minimally processed in terms of a processing penalty, provided that a certain performance constraint, e.g., intelligibility, is satisfied. We present a closed-form solution for the case where the performance criterion is an intelligibility estimator based on the approximated speech intelligibility index and the processing penalty is the mean-square error between the processed and the clean speech. This produces an NLE method that adapts to changing noise conditions via a simple gain rule by limiting the processing to the minimum necessary to achieve a desired intelligibility, while at the same time focusing on quality in favorable noise situations by minimizing the amount of speech distortions. Through simulation studies, we show the proposed method attains speech quality on par or better than existing methods in both objective measurements and subjective listening tests, whilst still sustaining objective speech intelligibility performance on par with existing methods

    Listening in large rooms : a neurophysiological investigations of acoustical conditions that influence speech intelligibility

    Get PDF
    Thesis (M.S.)--Massachusetts Institute of Technology, Whitaker College of Health Sciences and Technology, 1997.Includes bibliographical references (p. 34-37).by Benjamin Michael Hammond.M.S

    The effects of expansion on objective and subjective benefit in hearing-impaired listeners

    Get PDF
    The present research involves two studies. Twenty hearing-impaired participants were divided into two groups depending on their audiometric data and binaurally fit with the Starkey Endeavour 3211 hearing instruments. Experiment I was designed to determine if the use of expansion technology affected objective and subjective benefit in hearing-impaired listeners. Probe microphone measures were obtained at 40, 50, and 60 dB SPL and with the speaker deactivated to ensure that the expansion feature was functioning. Listener performance was measured in quite using the Connected Speech Test (CST) and in noise using the Hearing in Noise Test (HINT) at 40, 50, and 60 dB SPL with expansion activated and deactivated. Participants were also asked to participate in a subjective portion of the experiment. They filled out a rating form twice a day in two settings: quiet and in noise, with expansion activated and deactivated. Results indicated that expansion negatively affected user performance, but participants significantly preferred the feature. Experiment II, very similar in design, examined expansion time constants and their effects on objective and subjective benefit in hearing-impaired listeners. Experiment II examined four different expansion time constants (128 ms, 512 ms, 2048 ms, 4056 ms) to determine their role on speech intelligibility in quiet and in noise with two levels of hearing-impaired subjects (one group was worse than the other). The CST and the HINT were administered at 65 dB SPL to determine listener performance. A similar subjective rating form was used in Experiment II. Participants were asked to rate the speed of the gain and/or reduction of gain in quiet and in noise while speaking and listening. Results indicated that as expansion time constants lengthened performance decreased. Results indicated that there was no preferred time constant and that as the time constant lengthened performance decreased
    corecore