167 research outputs found

    Optical biopsy of epithelial cancers by optical coherence tomography

    Get PDF
    Optical coherence tomography (OCT) is an optical technique that measures the backscattering of near-infrared light by tissue. OCT yields in 2D and 3D images at micrometer-scale resolution, thus providing optical biopsies, approaching the resolution of histopathological imaging. The technique has shown to allow in vivo differentiation between benign and malignant epithelial tissue, through qualitative assessment of OCT images, as well as by quantitative evaluation, e.g., functional OCT. This study aims to summarize the principles of OCT and to discuss the current literature on the diagnostic value of OCT in the diagnosis of epithelial (pre)malignant lesions. The authors did a systematic search of the electronic databases PubMed and Embase on OCT in the diagnostic process of (pre)malignant epithelial lesions. OCT is able to differentiate between benign and (pre)malignant lesions of epithelial origin in a wide variety of tissues. In this way, OCT can detect skin cancers, oral, laryngeal, and esophageal cancer as well as genital and bladder cancer. OCT is an innovative technique which enables an optical biopsy of epithelial lesions. The incorporation of OCT in specific tools, like handheld and catheter-based probes, will further improve the implementation of this technology in daily clinical practice

    Parametric imaging of attenuation by optical coherence tomography: review of models, methods, and clinical translation

    Get PDF
    SIGNIFICANCE: Optical coherence tomography (OCT) provides cross-sectional and volumetric images of backscattering from biological tissue that reveal the tissue morphology. The strength of the scattering, characterized by an attenuation coefficient, represents an alternative and complementary tissue optical property, which can be characterized by parametric imaging of the OCT attenuation coefficient. Over the last 15 years, a multitude of studies have been reported seeking to advance methods to determine the OCT attenuation coefficient and developing them toward clinical applications. AIM: Our review provides an overview of the main models and methods, their assumptions and applicability, together with a survey of preclinical and clinical demonstrations and their translation potential. RESULTS: The use of the attenuation coefficient, particularly when presented in the form of parametric en face images, is shown to be applicable in various medical fields. Most studies show the promise of the OCT attenuation coefficient in differentiating between tissues of clinical interest but vary widely in approach. CONCLUSIONS: As a future step, a consensus on the model and method used for the determination of the attenuation coefficient is an important precursor to large-scale studies. With our review, we hope to provide a basis for discussion toward establishing this consensus

    Side branch healing patterns of the Tryton dedicated bifurcation stent: a 1-year optical coherence tomography follow-up study

    Get PDF
    The bare-metal Tryton Side Branch (SB) Stent™ (Tryton Medical, Durham, NC, USA) is used with a drug-eluting stent (DES) in the main branch (MB) to treat bifurcation lesions. It is argued that a drug-eluting Tryton-version is needed to improve clinical outcomes, although previous registries have shown good clinical results. More insights in neo-intimal hyperplasia (NIH) growth patterns of the Tryton treatment strategy are needed to decide if and where to drug-coat the stent. Ten patients returned for follow-up angiography (mean follow-up time 393 ± 103 days) and optical coherence tomography (OCT) pullbacks from the MB were obtained in all patients and from the SB in six patients. A per-strut analysis showed an uncovered strut rate of 0.7 % and an incompletely-apposed strut rate of 0.8 %. Most incompletely-apposed struts were found at the bifurcation region, in the luminal half facing towards the SB. Mean NIH thickness in the proximal MB, distal MB and SB were 0.14 ± 0.11, 0.19 ± 0.11, and 0.34 ± 0.19 mm, respectively, with a variety of growth patterns observed in the SB. We found good vascular healing of the DES in the MB, while healing was less favourably in the SB part. Furthermore, we observed a variety of NIH growth patterns in this SB part and more studies are needed to investigate the relation between growth patterns and clinical outcomes

    Weight velocity equations with 14–448 days time separated weights should not be used for infants under 3 years of age

    Get PDF
    Abnormal growth of infants may indicate disease of the children, thus methods to identify growth disorders are wanted in medicine. We previously showed that two-time-points weight growth velocities at age t, calculated by a commercial software product as [Weight(t)− Weight(t − X)]/X, with X = 448 days, were erroneous due to the long separation of 448 days. We were convinced that shorter X-values would solve this accuracy problem. However, our hypothesis is that: “shorter time separations than 448 days cause a decreased accuracy of numerical weight velocity equations in realistic infant weights until an age of about three years”. Supporting evidence comes from analyzing how shorter X-values will affect the accuracy of two-time-points weight velocity calculations. We systematically varied X between 1 and 448 days of various P50/0SD-related standard weight curves: (a)P50/0SD with the weights separated by 1 day and X = 1,28,224,448 days; (b)P50/0SD with the weights at variable ages and X = 14–448 days; and (c)case (b)and incorporating weight fluctuations typically occurring in infants. Cases (b)and (c)include details observed in a clinical case. Our results show that the combination of weight fluctuations and varying time intervals between consecutive weights make weight velocity predictions worse for shorter X values in children younger than three years. Because these two causes of failure occur naturally in infants whose weight is regularly measured, other weight velocity equations face the same causes for inaccuracy. In conclusion, our hypothesis suggests that any software that predicts weight velocities should be abandoned in infants < 3 years. Practically, it should require that when (commercial)software weight velocity prediction suggests a medical problem, careful clinical checking should be mandatory, e.g. by linking predicted and exact weight velocities at age t (the latter from the mathematical first derivative at age t of standard weight curves)

    Randomized controlled ferret study to assess the direct impact of 2008-09 trivalent inactivated influenza vaccine on A(H1N1)pdm09 disease risk

    Get PDF
    During spring-summer 2009, several observational studies from Canada showed increased risk of medically-attended, laboratory-confirmed A(H1N1)pdm09 illness among prior recipients of 2008-09 trivalent inactivated influenza vaccine (TIV). Explanatory hypotheses included direct and indirect vaccine effects. In a randomized placebo-controlled ferret study, we tested whether prior receipt of 2008-09 TIV may have directly influenced A(H1N1)pdm09 illness. Thirty-two ferrets (16/group) received 0.5 mL intra-muscular injections of the Canadian-manufactured, commercially-available, non-adjuvanted, split 2008-09 Fluviral or PBS placebo on days 0 and 28. On day 49 all animals were challenged (Ch0) with A(H1N1)pdm09. Four ferrets per group were randomly selected for sacrifice at day 5 post-challenge (Ch+5) and the rest followed until Ch+14. Sera were tested for antibody to vaccine antigens and A(H1N1)pdm09 by hemagglutination inhibition (HI), microneutralization (MN), nucleoprotein-based ELISA and HA1-based microarray assays. Clinical characteristics and nasal virus titers were recorded pre-challenge then post-challenge until sacrifice when lung virus titers, cytokines and inflammatory scores were determined. Baseline characteristics were similar between the two groups of influenza-naïve animals. Antibody rise to vaccine antigens was evident by ELISA and HA1-based microarray but not by HI or MN assays; virus challenge raised antibody to A(H1N1)pdm09 by all assays in both groups. Beginning at Ch+2, vaccinated animals experienced greater loss of appetite and weight than placebo animals, reaching the greatest between-group difference in weight loss relative to baseline at Ch+5 (7.4% vs. 5.2%; p = 0.01). At Ch+ 5 vaccinated animals had higher lung virus titers (log-mean 4.96 vs. 4.23pfu/mL, respectively; p = 0.01), lung inflammatory scores (5.8 vs. 2.1, respectively; p = 0.051) and cytokine levels (p.0.05). At Ch+14, both groups had recovered. Findings in influenza-naïve, systematically-infected ferrets may not replicate the human experience. While they cannot be considered conclusive to explain human observations, these ferret findings are consistent with direct, adverse effect of prior 2008-09 TIV receipt on A(H1N1)pdm09 illness. As such, they warrant further in-depth investigation and search for possible mechanistic explanations

    Autoantibodies against type I IFNs in patients with life-threatening COVID-19

    Get PDF
    Interindividual clinical variability in the course of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is vast. We report that at least 101 of 987 patients with life-threatening coronavirus disease 2019 (COVID-19) pneumonia had neutralizing immunoglobulin G (IgG) autoantibodies (auto-Abs) against interferon-w (IFN-w) (13 patients), against the 13 types of IFN-a (36), or against both (52) at the onset of critical disease; a few also had auto-Abs against the other three type I IFNs. The auto-Abs neutralize the ability of the corresponding type I IFNs to block SARS-CoV-2 infection in vitro. These auto-Abs were not found in 663 individuals with asymptomatic or mild SARS-CoV-2 infection and were present in only 4 of 1227 healthy individuals. Patients with auto-Abs were aged 25 to 87 years and 95 of the 101 were men. A B cell autoimmune phenocopy of inborn errors of type I IFN immunity accounts for life-threatening COVID-19 pneumonia in at least 2.6% of women and 12.5% of men

    A search for resonances decaying into a Higgs boson and a new particle X in the XH → qqbb final state with the ATLAS detector

    Get PDF
    A search for heavy resonances decaying into a Higgs boson (H) and a new particle (X) is reported, utilizing 36.1 fb−1 of proton–proton collision data at collected during 2015 and 2016 with the ATLAS detector at the CERN Large Hadron Collider. The particle X is assumed to decay to a pair of light quarks, and the fully hadronic final state is analysed. The search considers the regime of high XH resonance masses, where the X and H bosons are both highly Lorentz-boosted and are each reconstructed using a single jet with large radius parameter. A two-dimensional phase space of XH mass versus X mass is scanned for evidence of a signal, over a range of XH resonance mass values between 1 TeV and 4 TeV, and for X particles with masses from 50 GeV to 1000 GeV. All search results are consistent with the expectations for the background due to Standard Model processes, and 95% CL upper limits are set, as a function of XH and X masses, on the production cross-section of the resonance
    corecore