168 research outputs found

    Gaia on-board metrology: basic angle and best focus

    Get PDF
    The Gaia payload ensures maximum passive stability using a single material, SiC, for most of its elements. Dedicated metrology instruments are, however, required to carry out two functions: monitoring the basic angle and refocusing the telescope. Two interferometers fed by the same laser are used to measure the basic angle changes at the level of Ό\muas (prad, micropixel), which is the highest level ever achieved in space. Two Shack-Hartmann wavefront sensors, combined with an ad-hoc analysis of the scientific data are used to define and reach the overall best-focus. In this contribution, the systems, data analysis, procedures and performance achieved during commissioning are presentedComment: 18 pages, 14 figures. To appear in SPIE proceedings 9143-30. Space Telescopes and Instrumentation 2014: Optical, Infrared, and Millimeter Wav

    Selected liver grafts from donation after circulatory death can be safely used for retransplantation – a multicenter retrospective study

    Get PDF
    Due to the growing number of liver transplantations (LTs), there is an increasing number of patients requiring retransplantation (reLT). Data on the use of grafts from extended criteria donors (ECD), especially donation after circulatory death (DCD), for reLT are lacking. We aimed to assess the outcome of patients undergoing reLT using a DCD graft in the Netherlands between 2001 and July 2018. Propensity score matching was used to match each DCD-reLT with three DBD-reLT cases. Primary outcomes were patient and graft survival. Secondary outcome was the incidence of biliary complications, especially nonanastomotic strictures (NAS). 21 DCD-reLT were compared with 63 matched DBD-reLTs. Donors in the DCD-reLT group had a significantly lower BMI (22.4 vs. 24.7 kg/m2, P-value = 0.02). Comparison of recipient demographics and ischemia times yielded no significant differences. Patient and graft survival rates were comparable between the two groups. However, the occurrence of nonanastomotic strictures after DCD-reLT was significantly higher (38.1% vs. 12.7%, P-value = 0.02). ReLT with DCD grafts does not result in inferior patient and graft survival compared with DBD grafts in selected patients. Therefore, DCD liver grafts should not routinely be declined for patients awaiting reLT

    Donor diabetes mellitus is a risk factor for diminished outcome after liver transplantation:a nationwide retrospective cohort study

    Get PDF
    BACKGROUND: With the growing incidence of diabetes mellitus (DM), an increasing number of organ donors with DM can be expected. We sought to investigate the association between donor DM with early post-transplant outcomes. METHODS: From a national cohort of adult liver transplant recipients (1996-2016), all recipients transplanted with a liver from a DM donor (n=69) were matched 1:2 with recipients of livers from non-DM donors (n=138). The primary end-point included early post-transplant outcome, such as the incidence of primary non-function (PNF), hepatic artery thrombosis (HAT), and 90-day graft survival. Cox regression analysis was used to analyze the impact of donor DM on graft failure. RESULTS: PNF was observed in 5.8% of grafts from DM donors versus 2.9% of non-DM donor grafts (p=0.31). Recipients of grafts derived from DM donors had a higher incidence of HAT (8.7% vs. 2.2%, p=0.03) and decreased 90-day graft survival (88.4% [70.9-91.1] vs. 96.4% [89.6-97.8], p=0.03) compared to recipients of grafts from non-DM donors. The adjusted hazard ratio for donor DM on graft survival was 2.21 (1.08-4.53, p=0.03). CONCLUSION: Donor DM is associated with diminished outcome early after liver transplantation. The increased incidence of HAT after transplantation of livers from DM donors requires further research

    Donor hepatectomy time influences ischemia-reperfusion injury of the biliary tree in donation after circulatory death liver transplantation

    Get PDF
    Background: Donor hepatectomy time is associated with graft survival after liver transplantation. The aim of this study was to identify the impact of donor hepatectomy time on biliary injury during donation after circulatory death liver transplantation. Methods: First, bile duct biopsies of livers included in (pre)clinical machine perfusion research were analyzed. Secondly, of the same livers, bile samples were collected during normothermic machine perfusion. Lastly, a nationwide retrospective cohort study was performed including 273 adult patients undergoing donation after circulatory death liver transplantation between January 1, 2002 and January 1, 2017. Primary endpoint was development of non-anastomotic biliary strictures within 2 years of donation after circulatory death liver transplantation. Cox proportiona

    <i>Gaia</i> Data Release 1. Summary of the astrometric, photometric, and survey properties

    Get PDF
    Context. At about 1000 days after the launch of Gaia we present the first Gaia data release, Gaia DR1, consisting of astrometry and photometry for over 1 billion sources brighter than magnitude 20.7. Aims. A summary of Gaia DR1 is presented along with illustrations of the scientific quality of the data, followed by a discussion of the limitations due to the preliminary nature of this release. Methods. The raw data collected by Gaia during the first 14 months of the mission have been processed by the Gaia Data Processing and Analysis Consortium (DPAC) and turned into an astrometric and photometric catalogue. Results. Gaia DR1 consists of three components: a primary astrometric data set which contains the positions, parallaxes, and mean proper motions for about 2 million of the brightest stars in common with the HIPPARCOS and Tycho-2 catalogues – a realisation of the Tycho-Gaia Astrometric Solution (TGAS) – and a secondary astrometric data set containing the positions for an additional 1.1 billion sources. The second component is the photometric data set, consisting of mean G-band magnitudes for all sources. The G-band light curves and the characteristics of ∌3000 Cepheid and RR-Lyrae stars, observed at high cadence around the south ecliptic pole, form the third component. For the primary astrometric data set the typical uncertainty is about 0.3 mas for the positions and parallaxes, and about 1 mas yr−1 for the proper motions. A systematic component of ∌0.3 mas should be added to the parallax uncertainties. For the subset of ∌94 000 HIPPARCOS stars in the primary data set, the proper motions are much more precise at about 0.06 mas yr−1. For the secondary astrometric data set, the typical uncertainty of the positions is ∌10 mas. The median uncertainties on the mean G-band magnitudes range from the mmag level to ∌0.03 mag over the magnitude range 5 to 20.7. Conclusions. Gaia DR1 is an important milestone ahead of the next Gaia data release, which will feature five-parameter astrometry for all sources. Extensive validation shows that Gaia DR1 represents a major advance in the mapping of the heavens and the availability of basic stellar data that underpin observational astrophysics. Nevertheless, the very preliminary nature of this first Gaia data release does lead to a number of important limitations to the data quality which should be carefully considered before drawing conclusions from the data

    Donor diabetes mellitus is a risk factor for diminished outcome after liver transplantation: a nationwide retrospective cohort study

    Get PDF
    With the growing incidence of diabetes mellitus (DM), an increasing number of organ donors with DM can be expected. We sought to investigate the association between donor DM with early post-transplant outcomes. From a national cohort of adult liver transplant recipients (1996–2016), all recipients transplanted with a liver from a DM donor (n = 69) were matched 1:2 with recipients of livers from non-DM donors (n = 138). The primary end-point included early post-transplant outcome, such as the incidence of primary nonfunction (PNF), hepatic artery thrombosis (HAT), and 90-day graft survival. Cox regression analy

    Gaia Data Release 2: The astrometric solution

    Get PDF
    Gaia Data Release 2 (Gaia DR2) contains results for 1693 million sources in the magnitude range 3 to 21 based on observations collected by the European Space Agency Gaia satellite during the first 22 months of its operational phase. We describe the input data, models, and processing used for the astrometric content of Gaia DR2, and the validation of these results performed within the astrometry task. Some 320 billion centroid positions from the pre-processed astrometric CCD observations were used to estimate the five astrometric parameters (positions, parallaxes, and proper motions) for 1332 million sources, and approximate positions at the reference epoch J2015.5 for an additional 361 million mostly faint sources. Special validation solutions were used to characterise the random and systematic errors in parallax and proper motion. For the sources with five-parameter astrometric solutions, the median uncertainty in parallax and position at the reference epoch J2015.5 is about 0.04 mas for bright (G<14 mag) sources, 0.1 mas at G=17 mag, and 0.7 mas at G=20 mag. In the proper motion components the corresponding uncertainties are 0.05, 0.2, and 1.2 mas/yr, respectively. The optical reference frame defined by Gaia DR2 is aligned with ICRS and is non-rotating with respect to the quasars to within 0.15 mas/yr. From the quasars and validation solutions we estimate that systematics in the parallaxes depending on position, magnitude, and colour are generally below 0.1 mas, but the parallaxes are on the whole too small by about 0.03 mas. Significant spatial correlations of up to 0.04 mas in parallax and 0.07 mas/yr in proper motion are seen on small (<1 deg) and intermediate (20 deg) angular scales. Important statistics and information for the users of the Gaia DR2 astrometry are given in the appendices.Includes STFC

    A multicentre outcome analysis to define global benchmarks for donation after circulatory death liver transplantation

    Get PDF
    BACKGROUND: To identify the best possible outcomes in liver transplantation from donation after circulatory death donors (DCD) and to propose outcome values, which serve as reference for individual liver recipients or patient groups. METHODS: Based on 2219 controlled DCD liver transplantations, collected from 17 centres in North America and Europe, we identified 1012 low-risk, primary, adult liver transplantations with a laboratory MELD of ≀20points, receiving a DCD liver with a total donor warm ischemia time of ≀30minutes and asystolic donor warm ischemia time of ≀15minutes. Clinically relevant outcomes were selected and complications were reported according to the Clavien-Dindo-Grading and the Comprehensive Complication Index (CCI). Corresponding benchmark cut-offs were based on median values of each centre, where the 75(th)-percentile was considered. RESULTS: Benchmark cases represented between 19.7% and 75% of DCD transplantations in participating centers. The one-year retransplant and mortality rate was 5.23% and 9.01%, respectively. Within the first year of follow-up, 51.1% of recipients developed at least one major complication (≄Clavien-Dindo-Grade-III). Benchmark cut-offs were ≀3days and ≀16days for ICU and hospital stay, ≀66% for severe recipient complications (≄Grade-III), ≀16.8% for ischemic cholangiopathy, and ≀38.9CCI points at one-year posttransplant. Comparisons with higher risk groups showed more complications and impaired graft survival, outside the benchmark cut-offs. Organ perfusion techniques reduced the complications to values below benchmark cut-offs, despite higher graft risk. CONCLUSIONS: Despite excellent 1-year survival, morbidity in benchmark cases remains high with more than half of recipients developing severe complications during 1-year follow-up. Benchmark cut-offs targeting morbidity parameters offer a valid tool to assess the protective value of new preservation technologies in higher risk groups, and provide a valid comparator cohort for future clinical trials. LAY SUMMARY: The best possible outcomes after liver transplantation of grafts donated after circulatory death (DCD) were defined using the concept of benchmarking. These were based on 2219 liver transplantations following controlled DCD donation in 17 centres worldwide. The following benchmark cut-offs for the most relevant outcome parameters were developed: ICU and hospital stay: ≀3 and ≀16 days; primary non function: ≀2.5%; renal replacement therapy: ≀9.6%; ischemic cholangiopathy: ≀16.8% and anastomotic strictures ≀28.4%. One-year graft loss and mortality were defined as ≀14.4% and 9.6%, respectively. Donor and recipient combinations with higher risk had significantly worse outcomes. The use of novel organ perfusion technology achieved similar, good results in this high-risk group with prolonged donor warm ischemia time, when compared to the benchmark cohort
    • 

    corecore