R&D results on a CsI-TTGEM based photodetector
The very high momentum particle identification detector proposed for the
ALICE upgrade is a focusing RICH using a C4F10 gaseous radiator. For the
detection of Cherenkov photons, one of the options currently under
investigation is to use a CsI coated Triple-Thick-GEM (CsI-TTGEM) with metallic
or resistive electrodes. We will present results from the laboratory studies as
well as preliminary results of beam tests of a RICH detector prototype
consisting of a CaF2 radiator coupled to a 10x10 cm2 CsI-TTGEM equipped with a
pad readout and GASSIPLEX-based front-end electronics. With such a prototype
the detection of Cherenkov photons simultaneously with minimum ionizing
particles has been achieved for the first time in a stable operation mode
VHMPID: a new detector for the ALICE experiment at LHC
This article presents the basic idea of VHMPID, an upgrade detector for the
ALICE experiment at LHC, CERN. The main goal of this detector is to extend the
particle identification capabilities of ALICE to give more insight into the
evolution of the hot and dense matter created in Pb-Pb collisions. Starting
from the physics motivations and working principles the challenges and current
status of development is detailed.Comment: 4 pages, 6 figures. To be published in EPJ Web of Conference
Removing krypton from xenon by cryogenic distillation to the ppq level
The XENON1T experiment aims for the direct detection of dark matter in a
cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired
sensitivity, the background induced by radioactive decays inside the detector
has to be sufficiently low. One major contributor is the -emitter
Kr which is an intrinsic contamination of the xenon. For the XENON1T
experiment a concentration of natural krypton in xenon Kr/Xe < 200
ppq (parts per quadrillion, 1 ppq = 10 mol/mol) is required. In this
work, the design of a novel cryogenic distillation column using the common
McCabe-Thiele approach is described. The system demonstrated a krypton
reduction factor of 6.410 with thermodynamic stability at process
speeds above 3 kg/h. The resulting concentration of Kr/Xe < 26 ppq
is the lowest ever achieved, almost one order of magnitude below the
requirements for XENON1T and even sufficient for future dark matter experiments
using liquid xenon, such as XENONnT and DARWIN
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.Comment: 10 pages, 5 figure
Transverse sphericity of primary charged particles in minimum bias proton-proton collisions at , 2.76 and 7 TeV
Measurements of the sphericity of primary charged particles in minimum bias
proton--proton collisions at , 2.76 and 7 TeV with the ALICE
detector at the LHC are presented. The observable is linearized to be collinear
safe and is measured in the plane perpendicular to the beam direction using
primary charged tracks with GeV/c in . The
mean sphericity as a function of the charged particle multiplicity at
mid-rapidity () is reported for events with different
scales ("soft" and "hard") defined by the transverse momentum of the leading
particle. In addition, the mean charged particle transverse momentum versus
multiplicity is presented for the different event classes, and the sphericity
distributions in bins of multiplicity are presented. The data are compared with
calculations of standard Monte Carlo event generators. The transverse
sphericity is found to grow with multiplicity at all collision energies, with a
steeper rise at low , whereas the event generators show the
opposite tendency. The combined study of the sphericity and the mean with multiplicity indicates that most of the tested event generators
produce events with higher multiplicity by generating more back-to-back jets
resulting in decreased sphericity (and isotropy). The PYTHIA6 generator with
tune PERUGIA-2011 exhibits a noticeable improvement in describing the data,
compared to the other tested generators.Comment: 21 pages, 9 captioned figures, 3 tables, authors from page 16,
published version, figures from
http://aliceinfo.cern.ch/ArtSubmission/node/308
Anisotropic flow of charged hadrons, pions and (anti-)protons measured at high transverse momentum in Pb-Pb collisions at TeV
The elliptic, , triangular, , and quadrangular, , azimuthal
anisotropic flow coefficients are measured for unidentified charged particles,
pions and (anti-)protons in Pb-Pb collisions at TeV
with the ALICE detector at the Large Hadron Collider. Results obtained with the
event plane and four-particle cumulant methods are reported for the
pseudo-rapidity range at different collision centralities and as a
function of transverse momentum, , out to GeV/.
The observed non-zero elliptic and triangular flow depends only weakly on
transverse momentum for GeV/. The small dependence
of the difference between elliptic flow results obtained from the event plane
and four-particle cumulant methods suggests a common origin of flow
fluctuations up to GeV/. The magnitude of the (anti-)proton
elliptic and triangular flow is larger than that of pions out to at least
GeV/ indicating that the particle type dependence persists out
to high .Comment: 16 pages, 5 captioned figures, authors from page 11, published
version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/186
Effective Rheology of Bubbles Moving in a Capillary Tube
We calculate the average volumetric flux versus pressure drop of bubbles
moving in a single capillary tube with varying diameter, finding a square-root
relation from mapping the flow equations onto that of a driven overdamped
pendulum. The calculation is based on a derivation of the equation of motion of
a bubble train from considering the capillary forces and the entropy production
associated with the viscous flow. We also calculate the configurational
probability of the positions of the bubbles.Comment: 4 pages, 1 figur
Particle-yield modification in jet-like azimuthal di-hadron correlations in Pb-Pb collisions at = 2.76 TeV
The yield of charged particles associated with high- trigger
particles ( GeV/) is measured with the ALICE detector in
Pb-Pb collisions at = 2.76 TeV relative to proton-proton
collisions at the same energy. The conditional per-trigger yields are extracted
from the narrow jet-like correlation peaks in azimuthal di-hadron correlations.
In the 5% most central collisions, we observe that the yield of associated
charged particles with transverse momenta GeV/ on the
away-side drops to about 60% of that observed in pp collisions, while on the
near-side a moderate enhancement of 20-30% is found.Comment: 15 pages, 2 captioned figures, 1 table, authors from page 10,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/350
Elliptic flow of charged particles in Pb-Pb collisions at 2.76 TeV
We report the first measurement of charged particle elliptic flow in Pb-Pb
collisions at 2.76 TeV with the ALICE detector at the CERN Large Hadron
Collider. The measurement is performed in the central pseudorapidity region
(||<0.8) and transverse momentum range 0.2< < 5.0 GeV/. The
elliptic flow signal v, measured using the 4-particle correlation method,
averaged over transverse momentum and pseudorapidity is 0.087 0.002
(stat) 0.004 (syst) in the 40-50% centrality class. The differential
elliptic flow v reaches a maximum of 0.2 near = 3
GeV/. Compared to RHIC Au-Au collisions at 200 GeV, the elliptic flow
increases by about 30%. Some hydrodynamic model predictions which include
viscous corrections are in agreement with the observed increase.Comment: 10 pages, 4 captioned figures, published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/389
Suppression of charged particle production at large transverse momentum in central Pb-Pb collisions at TeV
Inclusive transverse momentum spectra of primary charged particles in Pb-Pb
collisions at = 2.76 TeV have been measured by the ALICE
Collaboration at the LHC. The data are presented for central and peripheral
collisions, corresponding to 0-5% and 70-80% of the hadronic Pb-Pb cross
section. The measured charged particle spectra in and GeV/ are compared to the expectation in pp collisions at the same
, scaled by the number of underlying nucleon-nucleon
collisions. The comparison is expressed in terms of the nuclear modification
factor . The result indicates only weak medium effects ( 0.7) in peripheral collisions. In central collisions,
reaches a minimum of about 0.14 at -7GeV/ and increases
significantly at larger . The measured suppression of high- particles is stronger than that observed at lower collision energies,
indicating that a very dense medium is formed in central Pb-Pb collisions at
the LHC.Comment: 15 pages, 5 captioned figures, 3 tables, authors from page 10,
published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/98
- …