168 research outputs found
Elliptic flow of charged particles in Pb-Pb collisions at 2.76 TeV
We report the first measurement of charged particle elliptic flow in Pb-Pb
collisions at 2.76 TeV with the ALICE detector at the CERN Large Hadron
Collider. The measurement is performed in the central pseudorapidity region
(||<0.8) and transverse momentum range 0.2< < 5.0 GeV/. The
elliptic flow signal v, measured using the 4-particle correlation method,
averaged over transverse momentum and pseudorapidity is 0.087 0.002
(stat) 0.004 (syst) in the 40-50% centrality class. The differential
elliptic flow v reaches a maximum of 0.2 near = 3
GeV/. Compared to RHIC Au-Au collisions at 200 GeV, the elliptic flow
increases by about 30%. Some hydrodynamic model predictions which include
viscous corrections are in agreement with the observed increase.Comment: 10 pages, 4 captioned figures, published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/389
Use of complementary and alternative medicine at Norwegian and Danish hospitals
<p>Abstract</p> <p>Background</p> <p>Several studies have found that a high proportion of the population in western countries use complementary and alternative medicine (CAM). However, little is known about whether CAM is offered in hospitals. The aim of this study was to describe to what extent CAM is offered in Norwegian and Danish hospitals and investigate possible changes in Norway since 2001.</p> <p>Methods</p> <p>A one-page questionnaire was sent to all included hospitals in both countries. The questionnaire was sent to the person responsible for the clinical activity, typically the medical director. 99 hospitals in the authority (85%) in Norway and 126 in Denmark (97%) responded. Given contact persons were interviewed.</p> <p>Results</p> <p>CAM is presently offered in about 50% of Norwegian hospitals and one-third of Danish hospitals. In Norway CAM was offered in 50 hospitals, 40 of which involved acupuncture. 19 hospitals gave other alternative therapies like biofeedback, hypnosis, cupping, ear-acupuncture, herbal medicine, art therapy, homeopathy, reflexology, thought field therapy, gestalt therapy, aromatherapy, tai chi, acupressure, yoga, pilates and other. 9 hospitals offered more than one therapy form. In Denmark 38 hospitals offered acupuncture and one Eye Movement Desensitization and Reprocessing Light Therapy. The most commonly reported reason for offering CAM was scientific evidence in Denmark. In Norway it was the interest of a hospital employee, except for acupuncture where the introduction is more often initiated by the leadership and is more based on scientific evidence of effect. All persons (except one) responsible for the alternative treatment had a medical or allied health professional background and their education/training in CAM treatment varied substantially.</p> <p>Conclusions</p> <p>The extent of CAM being offered has increased substantially in Norway during the first decade of the 21<sup>st </sup>century. This might indicate a shift in attitude regarding CAM within the conventional health care system.</p
Two-pion Bose-Einstein correlations in central Pb-Pb collisions at = 2.76 TeV
The first measurement of two-pion Bose-Einstein correlations in central Pb-Pb
collisions at TeV at the Large Hadron Collider is
presented. We observe a growing trend with energy now not only for the
longitudinal and the outward but also for the sideward pion source radius. The
pion homogeneity volume and the decoupling time are significantly larger than
those measured at RHIC.Comment: 17 pages, 5 captioned figures, 1 table, authors from page 12,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/388
Suppression of charged particle production at large transverse momentum in central Pb-Pb collisions at TeV
Inclusive transverse momentum spectra of primary charged particles in Pb-Pb
collisions at = 2.76 TeV have been measured by the ALICE
Collaboration at the LHC. The data are presented for central and peripheral
collisions, corresponding to 0-5% and 70-80% of the hadronic Pb-Pb cross
section. The measured charged particle spectra in and GeV/ are compared to the expectation in pp collisions at the same
, scaled by the number of underlying nucleon-nucleon
collisions. The comparison is expressed in terms of the nuclear modification
factor . The result indicates only weak medium effects ( 0.7) in peripheral collisions. In central collisions,
reaches a minimum of about 0.14 at -7GeV/ and increases
significantly at larger . The measured suppression of high- particles is stronger than that observed at lower collision energies,
indicating that a very dense medium is formed in central Pb-Pb collisions at
the LHC.Comment: 15 pages, 5 captioned figures, 3 tables, authors from page 10,
published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/98
Measurement of D+- and D0 production in deep inelastic scattering using a lifetime tag at HERA
The production of D-+/-- and D-0-mesons has been measured with the ZEUS detector at HERA using an integrated luminosity of 133.6 pb(-1). The measurements cover the kinematic range 5 < Q(2) < 1000 GeV2, 0.02 < y < 0.7, 1.5 < p(T)(D) < 15 GeV and |eta(D)| < 1.6. Combinatorial background to the D-meson signals is reduced by using the ZEUS microvertex detector to reconstruct displaced secondary vertices. Production cross sections are compared with the predictions of next-to-leading-order QCD, which is found to describe the data well. Measurements are extrapolated to the full kinematic phase space in order to obtain the open-charm contribution, F-2(c (c) over bar), to the proton structure function, F-2
The Electronics and Data Acquisition System of the DarkSide Dark Matter Search
It is generally inferred from astronomical measurements that Dark Matter (DM)
comprises approximately 27\% of the energy-density of the universe. If DM is a
subatomic particle, a possible candidate is a Weakly Interacting Massive
Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for
evidence of WIMP-nuclear collisions. DS is located underground at the
Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three
active, embedded components; an outer water veto (CTF), a liquid scintillator
veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper
describes the data acquisition and electronic systems of the DS detectors,
designed to detect the residual ionization from such collisions
The ALICE Transition Radiation Detector: Construction, operation, and performance
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection. (c) 2017 CERN for the benefit of the Authors. Published by Elsevier B.V
Higher harmonic anisotropic flow measurements of charged particles in Pb-Pb collisions at 2.76 TeV
We report on the first measurement of the triangular , quadrangular
, and pentagonal charged particle flow in Pb-Pb collisions at 2.76
TeV measured with the ALICE detector at the CERN Large Hadron Collider. We show
that the triangular flow can be described in terms of the initial spatial
anisotropy and its fluctuations, which provides strong constraints on its
origin. In the most central events, where the elliptic flow and
have similar magnitude, a double peaked structure in the two-particle azimuthal
correlations is observed, which is often interpreted as a Mach cone response to
fast partons. We show that this structure can be naturally explained from the
measured anisotropic flow Fourier coefficients.Comment: 10 pages, 4 figures, published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/387
- …