796 research outputs found

    Forensic age diagnostics by magnetic resonance imaging of the proximal humeral epiphysis

    Get PDF
    The most commonly used radiological method for age estimation of living individuals is X-ray. Computed tomography is not commonly used due to high radiation exposure, which raises ethical concerns. This problem can be solved with the use of magnetic resonance imaging (MRI), which avoids the use of ionizing radiation. The purpose of the present study was to evaluate the utility of MRI analysis of the proximal humeral epiphyses for forensic age estimations of living individuals. In this study, 395 left proximal humeral epiphyses (patient age 12-30years) were evaluated with fast-spin-echo proton density-weighted image (FSE PD) sequences in a coronal oblique orientation on shoulder MRI images. A five-stage scoring system was used following the method of Dedouit et al. The intra- and interobserver reliabilities assessed using Cohen's kappa statistic were =0.818 and =0.798, respectively. According to this study, stage five first appeared at 20 and 21years of age in males and females, respectively. These results are not directly comparable to any other published study due to the lack of MRI data on proximal humeral head development. These findings may provide valuable information for legally important age thresholds using shoulder MRI. The current study demonstrates that MRI of the proximal humerus can support forensic age estimation. Further research is needed to establish a standardized protocol that can be applied worldwide

    Applicability of T1-weighted MRI in the assessment of forensic age based on the epiphyseal closure of the humeral head

    Get PDF
    This work investigates the value of magnetic resonance imaging analysis of proximal epiphyseal fusion in research examining the growth and development of the humerus and its potential utility in establishing forensic age estimation. In this study, 428 proximal humeral epiphyses (patient age, 12-30years) were evaluated with T1-weighted turbo spin echo (T1 TSE) sequences in coronal oblique orientation on shoulder MRI images. A scoring system was created following a combination of the Schmeling and Kellinghaus methods. Spearman's rank correlation analysis revealed a significant positive relationship between age and ossification stage of the proximal humeral epiphysis (all subjects: rho=0.664, p<0.001; males: 0.631, p<0.001; females: rho=0.651, p<0.001). The intra- and inter-observer reliability assessed using Cohen's kappa statistic was =0.898 and =0.828, respectively. The earliest age of epiphysis closure was 17years for females and 18years for males. MRI of the proximal humeral epiphysis can be considered advantageous for forensic age estimation of living individuals in a variety of situations, ranging from monitoring public health to estimating the age of illegal immigrants/asylum seekers, minors engaged in criminal activities, and illegal participants in competitive sports, without the danger of radiation exposure

    An explorative qualitative study to determine the footwear needs of workers in standing environments

    Get PDF
    Background: Many work places require standing for prolonged periods of time and are potentially damaging to health, with links to musculoskeletal disorders and acute trauma from workplace accidents. Footwear provides the only interaction between the body and the ground and therefore a potential means to impact musculoskeletal disorders. However, there is very limited research into the necessary design and development of footwear based on both the physical environmental constraints and the personal preference of the workers. Therefore, the purpose of this study is to explore workers needs for footwear in the ‘standing’ workplace in relation to MSD, symptoms, comfort and design. Method: Semi-structured interviews were conducted with participants from demanding work environments that require standing for high proportions of the working day. Thematic analysis was used to analyse the results and gain an exploratory understanding into the footwear needs of these workers. Results: Interviews revealed the environmental demands and a very high percentage of musculoskeletal disorders, including day to day discomfort and chronic problems. It was identified that when designing work footwear for standing environments, the functionality of the shoe for the environment must be addressed, the sensations and symptoms of the workers taken into account to encourage adherence and the decision influencers should be met to encourage initial footwear choice. Meeting all these criteria could encourage the use of footwear with the correct safety features and comfort. Development of the correct footwear and increased education regarding foot health and footwear choice could help to reduce or improve the effect of the high number of musculoskeletal disorders repeatedly recorded in jobs that require prolonged periods of standing. Conclusion: This study provides a unique insight into the footwear needs of some workers in environments that require prolonged standing. This user based enquiry has provided information which is important to workplace footwear design

    Measurement of the t(t)over-bar production cross section in the dilepton channel in pp collisions at √s=8 TeV

    Get PDF
    The top-antitop quark (t (t) over bar) production cross section is measured in proton-proton collisions at root s = 8 TeV with the CMS experiment at the LHC, using a data sample corresponding to an integrated luminosity of 5.3 fb(-1). The measurement is performed by analysing events with a pair of electrons or muons, or one electron and one muon, and at least two jets, one of which is identified as originating from hadronisation of a bottom quark. The measured cross section is 239 +/- 2 (stat.) +/- 11 (syst.) +/- 6 (lum.) pb, for an assumed top-quark mass of 172.5 GeV, in agreement with the prediction of the standard model

    A Comparison of the Conditioning Regimens BEAM and FEAM for Autologous Hematopoietic Stem Cell Transplantation in Lymphoma: An Observational Study on 1038 Patients From Fondazione Italiana Linfomi

    Get PDF
    Abstract Background Carmustine (BCNU)-Etoposide-Citarabine-Melphalan (BEAM) chemotherapy is the standard conditioning regimen for autologous stem cell transplantation (ASCT) in lymphomas. Owing to BCNU shortages, many centers switched to Fotemustine-substituted BEAM (FEAM), lacking proof of equivalence. Methods We conducted a retrospective cohort study in 18 Italian centers to compare safety and efficacy of BEAM and FEAM regimens for ASCT in lymphomas performed from 2008 to 2015. Results We enrolled 1038 patients (BEAM n=607, FEAM n=431), of which 27% had Hodgkin's lymphoma (HL), 14% indolent Non-Hodgkin's lymphoma (iNHL) and 59% aggressive NHL (aNHL). Baseline characteristics including age, sex, stage, B-symptoms, extranodal involvement, previous treatments, response before ASCT, overall conditioning intensity, were well balanced between BEAM and FEAM; notable exceptions were: ASCT year (median: BEAM=2011 vs FEAM=2013, p Conclusions BEAM and FEAM do not appear different in terms of survival and disease control. However, due to concerns of higher toxicity, Fotemustine substitution in BEAM does not seem justified, if not for easier supply

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter
    corecore