615 research outputs found

    Computerized clinical documentation system in the pediatric intensive care unit

    Get PDF
    BACKGROUND: To determine whether a computerized clinical documentation system (CDS): 1) decreased time spent charting and increased time spent in patient care; 2) decreased medication errors; 3) improved clinical decision making; 4) improved quality of documentation; and/or 5) improved shift to shift nursing continuity. METHODS: Before and after implementation of CDS, a time study involving nursing care, medication delivery, and normalization of serum calcium and potassium values was performed. In addition, an evaluation of completeness of documentation and a clinician survey of shift to shift reporting were also completed. This was a modified one group, pretest-posttest design. RESULTS: With the CDS there was: improved legibility and completeness of documentation, data with better accessibility and accuracy, no change in time spent in direct patient care or charting by nursing staff. Incidental observations from the study included improved management functions of our nurse manager; improved JCAHO documentation compliance; timely access to clinical data (labs, vitals, etc); a decrease in time and resource use for audits; improved reimbursement because of the ability to reconstruct lost charts; limited human data entry by automatic data logging; eliminated costs of printing forms. CDS cost was reasonable. CONCLUSIONS: When compared to a paper chart, the CDS provided a more legible, compete, and accessible patient record without affecting time spent in direct patient care. The availability of the CDS improved shift to shift reporting. Other observations showed that the CDS improved management capabilities; helped physicians deliver care; improved reimbursement; limited data entry errors; and reduced costs

    Task-oriented evaluation of electronic medical records systems: development and validation of a questionnaire for physicians

    Get PDF
    BACKGROUND: Evaluation is a challenging but necessary part of the development cycle of clinical information systems like the electronic medical records (EMR) system. It is believed that such evaluations should include multiple perspectives, be comparative and employ both qualitative and quantitative methods. Self-administered questionnaires are frequently used as a quantitative evaluation method in medical informatics, but very few validated questionnaires address clinical use of EMR systems. METHODS: We have developed a task-oriented questionnaire for evaluating EMR systems from the clinician's perspective. The key feature of the questionnaire is a list of 24 general clinical tasks. It is applicable to physicians of most specialties and covers essential parts of their information-oriented work. The task list appears in two separate sections, about EMR use and task performance using the EMR, respectively. By combining these sections, the evaluator may estimate the potential impact of the EMR system on health care delivery. The results may also be compared across time, site or vendor. This paper describes the development, performance and validation of the questionnaire. Its performance is shown in two demonstration studies (n = 219 and 80). Its content is validated in an interview study (n = 10), and its reliability is investigated in a test-retest study (n = 37) and a scaling study (n = 31). RESULTS: In the interviews, the physicians found the general clinical tasks in the questionnaire relevant and comprehensible. The tasks were interpreted concordant to their definitions. However, the physicians found questions about tasks not explicitly or only partially supported by the EMR systems difficult to answer. The two demonstration studies provided unambiguous results and low percentages of missing responses. In addition, criterion validity was demonstrated for a majority of task-oriented questions. Their test-retest reliability was generally high, and the non-standard scale was found symmetric and ordinal. CONCLUSION: This questionnaire is relevant for clinical work and EMR systems, provides reliable and interpretable results, and may be used as part of any evaluation effort involving the clinician's perspective of an EMR system

    Do Electronic Health Records Help or Hinder Medical Education?

    Get PDF
    Many countries worldwide are digitizing patients' medical records. What impact will these electronic health records have upon medical education? This debate examines the threats and opportunities

    Effects of Phosphodiesterase 4 Inhibition on Alveolarization and Hyperoxia Toxicity in Newborn Rats

    Get PDF
    International audienceBACKGROUND: Prolonged neonatal exposure to hyperoxia is associated with high mortality, leukocyte influx in airspaces, and impaired alveolarization. Inhibitors of type 4 phosphodiesterases are potent anti-inflammatory drugs now proposed for lung disorders. The current study was undertaken to determine the effects of the prototypal phosphodiesterase-4 inhibitor rolipram on alveolar development and on hyperoxia-induced lung injury. METHODOLOGY/FINDINGS: Rat pups were placed under hyperoxia (FiO2>95%) or room air from birth, and received rolipram or its diluent daily until sacrifice. Mortality rate, weight gain and parameters of lung morphometry were recorded on day 10. Differential cell count and cytokine levels in bronchoalveolar lavage and cytokine mRNA levels in whole lung were recorded on day 6. Rolipram diminished weight gain either under air or hyperoxia. Hyperoxia induced huge mortality rate reaching 70% at day 10, which was prevented by rolipram. Leukocyte influx in bronchoalveolar lavage under hyperoxia was significantly diminished by rolipram. Hyperoxia increased transcript and protein levels of IL-6, MCP1, and osteopontin; rolipram inhibited the increase of these proteins. Alveolarization was impaired by hyperoxia and was not restored by rolipram. Under room air, rolipram-treated pups had significant decrease of Radial Alveolar Count. CONCLUSIONS: Although inhibition of phosphodiesterases 4 prevented mortality and lung inflammation induced by hyperoxia, it had no effect on alveolarization impairment, which might be accounted for by the aggressiveness of the model. The less complex structure of immature lungs of rolipram-treated pups as compared with diluent-treated pups under room air may be explained by the profound effect of PDE4 inhibition on weight gain that interfered with normal alveolarization

    IT-adoption and the interaction of task, technology and individuals: a fit framework and a case study

    Get PDF
    BACKGROUND: Factors of IT adoption have largely been discussed in the literature. However, existing frameworks (such as TAM or TTF) are failing to include one important aspect, the interaction between user and task. METHOD: Based on a literature study and a case study, we developed the FITT framework to help analyse the socio-organisational-technical factors that influence IT adoption in a health care setting. RESULTS: Our FITT framework ("Fit between Individuals, Task and Technology") is based on the idea that IT adoption in a clinical environment depends on the fit between the attributes of the individual users (e.g. computer anxiety, motivation), attributes of the technology (e.g. usability, functionality, performance), and attributes of the clinical tasks and processes (e.g. organisation, task complexity). We used this framework in the retrospective analysis of a three-year case study, describing the adoption of a nursing documentation system in various departments in a German University Hospital. We will show how the FITT framework helped analyzing the process of IT adoption during an IT implementation: we were able to describe every found IT adoption problem with regard to the three fit dimensions, and any intervention on the fit can be described with regard to the three objects of the FITT framework (individual, task, technology). We also derive facilitators and barriers to IT adoption of clinical information systems. CONCLUSION: This work should support a better understanding of the reasons for IT adoption failures and therefore enable better prepared and more successful IT introduction projects. We will discuss, however, that from a more epistemological point of view, it may be difficult or even impossible to analyse the complex and interacting factors that predict success or failure of IT projects in a socio-technical environment

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Search for the neutral Higgs bosons of the minimal supersymmetric standard model in pp collisions at root s=7 TeV with the ATLAS detector

    Get PDF
    A search for neutral Higgs bosons of the Minimal Supersymmetric Standard Model (MSSM) is reported. The analysis is based on a sample of proton-proton collisions at a centre-of-mass energy of 7TeV recorded with the ATLAS detector at the Large Hadron Collider. The data were recorded in 2011 and correspond to an integrated luminosity of 4.7 fb-1 to 4.8 fb-1. Higgs boson decays into oppositely-charged muon or τ lepton pairs are considered for final states requiring either the presence or absence of b-jets. No statistically significant excess over the expected background is observed and exclusion limits at the 95% confidence level are derived. The exclusion limits are for the production cross-section of a generic neutral Higgs boson, φ, as a function of the Higgs boson mass and for h/A/H production in the MSSM as a function of the parameters mA and tan β in the mhmax scenario for mA in the range of 90GeV to 500 GeV. Copyright CERN

    Search for R-parity-violating supersymmetry in events with four or more leptons in sqrt(s) =7 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for new phenomena in final states with four or more leptons (electrons or muons) is presented. The analysis is based on 4.7 fb−1 of s=7  TeV \sqrt{s}=7\;\mathrm{TeV} proton-proton collisions delivered by the Large Hadron Collider and recorded with the ATLAS detector. Observations are consistent with Standard Model expectations in two signal regions: one that requires moderate values of missing transverse momentum and another that requires large effective mass. The results are interpreted in a simplified model of R-parity-violating supersymmetry in which a 95% CL exclusion region is set for charged wino masses up to 540 GeV. In an R-parity-violating MSUGRA/CMSSM model, values of m 1/2 up to 820 GeV are excluded for 10 < tan β < 40

    Search for high-mass resonances decaying to dilepton final states in pp collisions at s√=7 TeV with the ATLAS detector

    Get PDF
    The ATLAS detector at the Large Hadron Collider is used to search for high-mass resonances decaying to an electron-positron pair or a muon-antimuon pair. The search is sensitive to heavy neutral Z′ gauge bosons, Randall-Sundrum gravitons, Z * bosons, techni-mesons, Kaluza-Klein Z/γ bosons, and bosons predicted by Torsion models. Results are presented based on an analysis of pp collisions at a center-of-mass energy of 7 TeV corresponding to an integrated luminosity of 4.9 fb−1 in the e + e − channel and 5.0 fb−1 in the μ + μ −channel. A Z ′ boson with Standard Model-like couplings is excluded at 95 % confidence level for masses below 2.22 TeV. A Randall-Sundrum graviton with coupling k/MPl=0.1 is excluded at 95 % confidence level for masses below 2.16 TeV. Limits on the other models are also presented, including Technicolor and Minimal Z′ Models
    corecore