23 research outputs found

    Electronic Raman scattering and photoluminescence from La0.7_{0.7}Sr0.3_{0.3}MnO3_3 exhibiting giant magnetoresistance

    Full text link
    Raman and Photoluminescence (PL) experiments on correlated metallic La0.7_{0.7}Sr0.3_{0.3}MnO3_{3} have been carried out using different excitation wavelengths as a function of temperature from 15 K to 300 K. Our data suggest a Raman mode centered at 1800 cm−1^{-1} and a PL band at 2.2 eV. The intensities of the two peaks decrease with increasing temperature. The Raman mode can be attributed to a plasmon excitation whose frequency and linewidths are consistent with the measured resistivities. The PL involves intersite electronic transitions of the manganese ions.Comment: 10 pages + 4 eps figures, Revtex 3.0, figures available on reques

    The performance of the jet trigger for the ATLAS detector during 2011 data taking

    Get PDF
    The performance of the jet trigger for the ATLAS detector at the LHC during the 2011 data taking period is described. During 2011 the LHC provided proton–proton collisions with a centre-of-mass energy of 7 TeV and heavy ion collisions with a 2.76 TeV per nucleon–nucleon collision energy. The ATLAS trigger is a three level system designed to reduce the rate of events from the 40 MHz nominal maximum bunch crossing rate to the approximate 400 Hz which can be written to offline storage. The ATLAS jet trigger is the primary means for the online selection of events containing jets. Events are accepted by the trigger if they contain one or more jets above some transverse energy threshold. During 2011 data taking the jet trigger was fully efficient for jets with transverse energy above 25 GeV for triggers seeded randomly at Level 1. For triggers which require a jet to be identified at each of the three trigger levels, full efficiency is reached for offline jets with transverse energy above 60 GeV. Jets reconstructed in the final trigger level and corresponding to offline jets with transverse energy greater than 60 GeV, are reconstructed with a resolution in transverse energy with respect to offline jets, of better than 4 % in the central region and better than 2.5 % in the forward direction

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved

    Screening for maternal coeliac disease as a potential risk factor for orofacial clefts--a pilot study

    No full text
    Item does not contain fulltextThere is increasing evidence that dietary folic acid deficiency in utero may increase the risk of developing the 'cleft lip with or without cleft palate' (CL+/-P) variant of orofacial cleft. Coeliac disease is a common cause of folic acid malabsorption, and in the majority of cases remains undiagnosed. This pilot study assessed the seroprevalence of undiagnosed coeliac disease in a cohort of mothers of infants with CL+/-P in the Hyderabad area of India. The seroprevalence of coeliac disease of 1.15% (95% confidence interval 0.37-2.66%) was little different from the expected figure based on published population studies, making a clinically significant association unlikely
    corecore