    Calibration of TCCON column-averaged CO2: the first aircraft campaign over European TCCON sites

    Get PDF
    The Total Carbon Column Observing Network (TCCON) is a ground-based network of Fourier Transform Spectrometer (FTS) sites around the globe, where the column abundances of CO2, CH4, N2O, CO and O2 are measured. CO2 is constrained with a precision better than 0.25% (1-σ). To achieve a similarly high accuracy, calibration to World Meteorological Organization (WMO) standards is required. This paper introduces the first aircraft calibration campaign of five European TCCON sites and a mobile FTS instrument. A series of WMO standards in-situ profiles were obtained over European TCCON sites via aircraft and compared with retrievals of CO2 column amounts from the TCCON instruments. The results of the campaign show that the FTS measurements are consistently biased 1.1% ¹ 0.2% low with respect to WMO standards, in agreement with previous TCCON calibration campaigns. The standard a priori profile for the TCCON FTS retrievals is shown to not add a bias. The same calibration factor is generated using aircraft profiles as a priori and with the TCCON standard a priori. With a calibration to WMO standards, the highly precise TCCON CO2 measurements of total column concentrations provide a suitable database for the calibration and validation of nadir-viewing satellite

    Relationship Between the King-Devick Test and Commonly Used Concussion Tests at Baseline

    Get PDF
    Context: Comprehensive assessments are recommended to evaluate sport-related concussion (SRC). The degree to which the King-Devick (KD) test adds novel information to an SRC evaluation is unknown. Objective: To describe relationships at baseline among the KD and other SRC assessments and explore whether the KD provides unique information to a multimodal baseline concussion assessment. Design: Cross-sectional study. Setting: Five National Collegiate Athletic Association institutions participating in the Concussion Assessment, Research and Education (CARE) Consortium. Patients or other participants: National Collegiate Athletic Association student-athletes (N = 2258, age = 20 ¹ 1.5 years, 53.0% male, 68.9% white) in 11 men's and 13 women's sports. Main outcome measure(s): Participants completed baseline assessments on the KD and (1) the Symptom Inventory of the Sport Concussion Assessment Tool-3rd edition, (2) the Brief Symptom Inventory-18, (3) the Balance Error Scoring System, (4) the Standardized Assessment of Concussion (SAC), (5) the Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) test battery, and (6) the Vestibular/Ocular Motor Screening tool during their first year in CARE. Correlation coefficients between the KD and the 6 other concussion assessments in isolation were determined. Assessments with ρ magnitude >0.1 were included in a multivariate linear regression analysis to evaluate their relative association with the KD. Results: Scores for SAC concentration, ImPACT visual motor speed, and ImPACT reaction time were correlated with the KD (ρ = -0.216, -0.276, and 0.164, respectively) and were thus included in the regression model, which explained 16.8% of the variance in baseline KD time (P < .001, Cohen f2 = 0.20). Better SAC concentration score (β = -.174, P < .001), ImPACT visual motor speed (β = -.205, P < .001), and ImPACT reaction time (β = .056, P = .020) were associated with faster baseline KD performance, but the effect sizes were small. Conclusions: Better performance on cognitive measures involving concentration, visual motor speed, and reaction time was weakly associated with better baseline KD performance. Symptoms, psychological distress, balance, and vestibular-oculomotor provocation were unrelated to KD performance at baseline. The findings indicate limited overlap at baseline among the CARE SRC assessments and the KD

    Decarbonisation of transport: options and challenges

    Get PDF
    This EASAC report reviews options for reducing greenhouse gas (GHG) emissions from European transport. It argues for stronger policies to bridge the gap between the GHG emission reductions that will be delivered by current policies and the levels needed to limit global warming to less than 2°C or even 1.5°C (Paris Agreement). The report focusses on road transport because, in the EU, this contributes 72% of transport GHG emissions. EASAC recommends a combination of transitional measures for the next 10-15 years and sustainable measures for the long term, based on a three level policy framework: avoid and contain demand for transport services; shift passengers and freight to transport modes with lower emissions (trains, buses and ships); and improve performance through vehicle design, more efficient powertrains and replacing fossil fuels with sustainable energy carriers including low-carbon electricity, hydrogen and synthetic fuels. Opportunities for the EU to strengthen its industrial competitiveness and create high quality jobs are also discussed

    Decarbonisation of transport: options and challenges

    Get PDF
    This EASAC report reviews options for reducing greenhouse gas (GHG) emissions from European transport. It argues for stronger policies to bridge the gap between the GHG emission reductions that will be delivered by current policies and the levels needed to limit global warming to less than 2\xc2\xb0C or even 1.5\xc2\xb0C (Paris Agreement). The report focusses on road transport because, in the EU, this contributes 72% of transport GHG emissions. EASAC recommends a combination of transitional measures for the next 10-15 years and sustainable measures for the long term, based on a three level policy framework: avoid and contain demand for transport services; shift passengers and freight to transport modes with lower emissions (trains, buses and ships); and improve performance through vehicle design, more efficient powertrains and replacing fossil fuels with sustainable energy carriers including low-carbon electricity, hydrogen and synthetic fuels. Opportunities for the EU to strengthen its industrial competitiveness and create high quality jobs are also discussed

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
    • …