51 research outputs found

    Dynamic Modeling, Parameter Estimation and Control of a Leg Prosthesis Test Robot

    Get PDF
    Robotic testing can facilitate the development of new concepts, designs and control systems for prosthetic limbs. Human subject test clearances, safety and the lack of repeatability associated with human trials can be reduced or eliminated with automated testing, and test modalities are possible which are dangerous or inconvenient to attempt with patients. This paper describes the development, modeling, parameter estimation and control of a robot capable of reproducing two degree-of-freedom hip motion in the sagittal plane. Hip vertical displacement and thigh angle motion profiles are applied to a transfemoral prosthesis attached to the robot. A treadmill is used as walking surface. Aside from tracking hip motion trajectories, the control system can be used to regulate the contact force between the treadmill and the prosthesis. The paper summarizes the overall development process, with emphasis on the generation of a dynamic model that can be used to design closed-loop motion and force control algorithms

    The Extravehicular Suit Impact Load Attenuation Study for Use in Astronaut Bone Fracture Prediction

    Get PDF
    The NASA Integrated Medical Model (IMM) assesses the risk, including likelihood and impact of occurrence, of all credible in-flight medical conditions. Fracture of the proximal femur is a traumatic injury that would likely result in loss of mission if it were to happen during spaceflight. The low gravity exposure causes decreases in bone mineral density which heightens the concern. Researchers at the NASA Glenn Research Center have quantified bone fracture probability during spaceflight with a probabilistic model. It was assumed that a pressurized extravehicular activity (EVA) suit would attenuate load during a fall, but no supporting data was available. The suit impact load attenuation study was performed to collect analogous data. METHODS: A pressurized EVA suit analog test bed was used to study how the offset, defined as the gap between the suit and the astronaut s body, impact load magnitude and suit operating pressure affects the attenuation of impact load. The attenuation data was incorporated into the probabilistic model of bone fracture as a function of these factors, replacing a load attenuation value based on commercial hip protectors. RESULTS: Load attenuation was more dependent on offset than on pressurization or load magnitude, especially at small offsets. Load attenuation factors for offsets between 0.1 - 1.5 cm were 0.69 +/- 0.15, 0.49 +/- 0.22 and 0.35 +/- 0.18 for mean impact forces of 4827, 6400 and 8467 N, respectively. Load attenuation factors for offsets of 2.8 - 5.3 cm were 0.93 +/- 0.2, 0.94 +/- 0.1 and 0.84 +/- 0.5, for the same mean impact forces. Reductions were observed in the 95th percentile confidence interval of the bone fracture probability predictions. CONCLUSIONS: The reduction in uncertainty and improved confidence in bone fracture predictions increased the fidelity and credibility of the fracture risk model and its benefit to mission design and operational decisions

    Kinematic and EMG Comparison of Gait in Normal and Microgravity

    Get PDF
    Astronauts regularly perform treadmill locomotion as a part of their exercise prescription while onboard the International Space Station. Although locomotive exercise has been shown to be beneficial for bone, muscle, and cardiovascular health, astronauts return to Earth after long duration missions with net losses in all three areas [1]. These losses might be partially explained by fundamental differences in locomotive performance between normal gravity (NG) and microgravity (MG) environments. During locomotive exercise in MG, the subject must wear a waist and shoulder harness that is attached to elastomer bungees. The bungees are attached to the treadmill, and provide forces that are intended to replace gravity. However, unlike gravity, which provides a constant force upon all body parts, the bungees provide a spring force only to the harness. Therefore, subjects are subjected to two fundamental differences in MG: 1) forces returning the subject to the treadmill are not constant, and 2) forces are only applied to the axial skeleton at the waist and shoulders. The effectiveness of the exercise may also be affected by the magnitude of the gravity replacement load. Historically, astronauts have difficulty performing treadmill exercise with loads that approach body weight (BW) due to comfort and inherent stiffness in the bungee system. Although locomotion can be executed in MG, the unique requirements could result in performance differences as compared to NG. These differences may help to explain why long term training effects of treadmill exercise may differ from those found in NG. The purpose of this investigation was to compare locomotion in NG and MG to determine if kinematic or muscular activation pattern differences occur between gravitational environments

    Ground Based Microgravity Emissions Testing Of Flight Hardware

    Get PDF
    To control microgravity environment on the International Space Station (ISS), NASA developed payloads have to meet the payload integration requirements of the Space Station Program, specifically a microgravity allocation plan. The Microgravity Emissions Laboratory (MEL) was developed at NASA Glenn Research Center (GRC) for verification of the payloads compliance with payload integration requirements. MEL is a 6 degree of freedom inertial measurement system capable of characterizing the microgravity emissions, generated by a disturber, down to a micro g. Microgravity Emissions tests provide a payload developer with a tool to assess payload's compliance with the requirements, i.e. forces and moments, generated by the payload at its center of gravity. Forces and moments are presented in time domain for both stationary and transient signals, and in frequency domain for the stationary signals. To date, MEL conducted over thirty tests of ISS hardware. The test results are being successfully used by the payload developers for design verification and improvement

    Gravitational Effects upon Locomotion Posture

    Get PDF
    Researchers use actual microgravity (AM) during parabolic flight and simulated microgravity (SM) obtained with horizontal suspension analogs to better understand the effect of gravity upon gait. In both environments, the gravitational force is replaced by an external load (EL) that returns the subject to the treadmill. However, when compared to normal gravity (N), researchers consistently find reduced ground reaction forces (GRF) and subtle kinematic differences (Schaffner et al., 2005). On the International Space Station, the EL is applied by elastic bungees attached to a waist and shoulder harness. While bungees can provide EL approaching body weight (BW), their force-length characteristics coupled with vertical oscillations of the body during gait result in a variable load. However, during locomotion in N, the EL is consistently equal to 100% body weight. Comparisons between AM and N have shown that during running, GRF are decreased in AM (Schaffner et al, 2005). Kinematic evaluations in the past have focussed on joint range of motion rather than joint posture at specific instances of the gait cycle. The reduced GRF in microgravity may be a result of differing hip, knee, and ankle positions during contact. The purpose of this investigation was to compare joint angles of the lower extremities during walking and running in AM, SM, and N. We hypothesized that in AM and SM, joints would be more flexed at heel strike (HS), mid-stance (MS) and toe-off (TO) than in N

    Verification of a 2 kWe Closed-Brayton-Cycle Power Conversion System Mechanical Dynamics Model

    Get PDF
    Vibration test data from an operating 2 kWe closed-Brayton-cycle (CBC) power conversion system (PCS) located at the NASA Glenn Research Center was used for a comparison with a dynamic disturbance model of the same unit. This effort was performed to show that a dynamic disturbance model of a CBC PCS can be developed that can accurately predict the torque and vibration disturbance fields of such class of rotating machinery. The ability to accurately predict these disturbance fields is required before such hardware can be confidently integrated onto a spacecraft mission. Accurate predictions of CBC disturbance fields will be used for spacecraft control/structure interaction analyses and for understanding the vibration disturbances affecting the scientific instrumentation onboard. This paper discusses how test cell data measurements for the 2 kWe CBC PCS were obtained, the development of a dynamic disturbance model used to predict the transient torque and steady state vibration fields of the same unit, and a comparison of the two sets of data

    Testing of Composite Fan Vanes With Erosion-Resistant Coating Accelerated

    Get PDF
    The high-cycle fatigue of composite stator vanes provided an accelerated life-state prior to insertion in a test stand engine. The accelerated testing was performed in the Structural Dynamics Laboratory at the NASA Glenn Research Center under the guidance of Structural Mechanics and Dynamics Branch personnel. Previous research on fixturing and test procedures developed at Glenn determined that engine vibratory conditions could be simulated for polymer matrix composite vanes by using the excitation of a combined slip table and electrodynamic shaker in Glenn's Structural Dynamics Laboratory. Bench-top testing gave researchers the confidence to test the coated vanes in a full-scale engine test

    Collagen organization deposited by fibroblasts encapsulated in pH responsive methacrylated alginate hydrogels

    Get PDF
    The pH of dermal wounds shifts from neutral during the inflammatory phase to slightly basic in the tissue remodeling phase. Stage specific wound treatment can be developed using environmentally responsive alginate hydrogels. The chemistry of these networks dictates swelling behavior. Here, we fabricated alginate hydrogels using chain growth, step growth, and combined mixed mode gelation methods to crosslink methacrylated alginate (ALGMA) and gain control over swelling responses. Methacrylation of the alginate network was confirmed through NMR spectroscopy. Strontium cations were introduced to fabricate stiffer, dually crosslinked hydrogels. Dual crosslinking significantly decreased the swelling response over the pH range of 3–9 for step growth and chain growth hydrogels, with no impact on mixed mode hydrogels. The extent of crosslinking altered the hydrogel degradation profiles under accelerated degradation conditions. Encapsulated NIH/3T3 fibroblasts in the different ALGMA hydrogels remained viable with greater cell proliferation in the stiffer gels. Collagen organization deposited by the NIH/3T3 fibroblasts was monitored using second harmonic generation (SHG) microscopy and was influenced by the crosslinking mechanism. Ionic chain growth and ionic mixed mode crosslinked ALGMA hydrogels caused relatively isotropic collagen organization, particularly 10 days post‐cell encapsulation. Principal component analysis (PCA) was employed to uncover correlations between the observed properties. The ability of these environmentally responsive gels to induce isotropic collagen and respond to pH changes means they hold promise as phase specific wound dressings

    3D bioactive composite scaffolds for bone tissue engineering

    Get PDF
    Bone is the second most commonly transplanted tissue worldwide, with over four million operations using bone grafts or bone substitute materials annually to treat bone defects. However, significant limitations affect current treatment options and clinical demand for bone grafts continues to rise due to conditions such as trauma, cancer, infection and arthritis. Developing bioactive three-dimensional (3D) scaffolds to support bone regeneration has therefore become a key area of focus within bone tissue engineering (BTE). A variety of materials and manufacturing methods including 3D printing have been used to create novel alternatives to traditional bone grafts. However, individual groups of materials including polymers, ceramics and hydrogels have been unable to fully replicate the properties of bone when used alone. Favourable material properties can be combined and bioactivity improved when groups of materials are used together in composite 3D scaffolds. This review will therefore consider the ideal properties of bioactive composite 3D scaffolds and examine recent use of polymers, hydrogels, metals, ceramics and bio-glasses in BTE. Scaffold fabrication methodology, mechanical performance, biocompatibility, bioactivity, and potential clinical translations will be discussed

    Microgravity Emissions Laboratory Testing of the Light Microscopy Module Control Box Fan

    No full text
    The Microgravity Emissions Laboratory (MEL) was developed at the NASA Glenn Research Center for the characterization, simulation, and verification of the International Space Station (ISS) microgravity environment. This Glenn lab was developed in support of the Fluids and Combustion Facility (FCF). The MEL is a six-degrees-of-freedom inertial measurement system that can characterize the inertial response forces (emissions) of components, subrack payloads, or rack-level payloads down to 10 7g. The inertial force output data generated from the steady-state or transient operations of the test article are used with finite element analysis, statistical energy analysis, and other analysis tools to predict the on-orbit environment at specific science or rack interface locations. Customers of the MEL have used benefits in isolation performance testing in defining available attenuation during the engineering hardware design phase of their experiment s development. The Light Microscopy Module (LMM) Control Box (LCB) fan was tested in the MEL in June and July of 2002. The LMM is planned as a remotely controllable on-orbit microscope subrack facility that will be accommodated in an FCF Fluids Integrated Rack on the ISS. The disturbances measured in the MEL test resulted from operation of the air-circulation fan within the LCB. The objectives of the testing were (1) to identify an isolator to be added to the LCB fan assembly to reduce fan-speed harmonics and (2) to identify the fan-disturbance forcing functions for use in rack-response analysis of the LMM and Fluids Integrated Rack facility. This report describes the MEL, the testing process, and the results from ground-based MEL LCB fan testing
    corecore