485 research outputs found

    Supersymmetric Chern-Simons Theories with Vector Matter

    Full text link
    In this paper we discuss SU(N) Chern-Simons theories at level k with both fermionic and bosonic vector matter. In particular we present an exact calculation of the free energy of the N=2 supersymmetric model (with one chiral field) for all values of the 't Hooft coupling in the large N limit. This is done by using a generalization of the standard Hubbard-Stratanovich method because the SUSY model contains higher order polynomial interactions.Comment: 46 pages, 24 figures, v2: comments and references added, v3: a footnote in Section 3.5 adde

    On The Stability Of Non-Supersymmetric AdS Vacua

    Get PDF
    We consider two infinite families of Non-Supersymmetric AdS4AdS_4 vacua, called Type 2) and Type 3) vacua, that arise in massive IIA supergravity with flux. We show that both families are perturbatively stable. We then examine non-perturbative decays of these vacua to other supersymmetric and non-supersymmetric AdS4AdS_4 vacua mediated by instantons in the thin wall approximation. We find that many decays are ruled out since the tension of the interpolating domain wall is too big compared to the energy difference in AdS units. In fact, within our approximations no decays of Type 2) vacua are allowed, although some decays are only marginally forbidden. This can be understood in terms of a "pairing symmetry" in the landscape which relate Type 2) vacua with supersymmetric ones of the same energy.Comment: 50 pages, Minor changes in section 2.2.

    Usability evaluation of a clinical decision support tool for osteoporosis disease management

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Osteoporosis affects over 200 million people worldwide at a high cost to healthcare systems. Although guidelines are available, patients are not receiving appropriate diagnostic testing or treatment. Findings from a systematic review of osteoporosis interventions and a series of focus groups were used to develop a functional multifaceted tool that can support clinical decision-making in osteoporosis disease management at the point of care. The objective of our study was to assess how well the prototype met functional goals and usability needs.</p> <p>Methods</p> <p>We conducted a usability study for each component of the tool--the Best Practice Recommendation Prompt (BestPROMPT), the Risk Assessment Questionnaire (RAQ), and the Customised Osteoporosis Education (COPE) sheet--using the framework described by Kushniruk and Patel. All studies consisted of one-on-one sessions with a moderator using a standardised worksheet. Sessions were audio- and video-taped and transcribed verbatim. Data analysis consisted of a combination of qualitative and quantitative analyses.</p> <p>Results</p> <p>In study 1, physicians liked that the BestPROMPT can provide customised recommendations based on risk factors identified from the RAQ. Barriers included lack of time to use the tool, the need to alter clinic workflow to enable point-of-care use, and that the tool may disrupt the real reason for the visit. In study 2, patients completed the RAQ in a mean of 6 minutes, 35 seconds. Of the 42 critical incidents, 60% were navigational and most occurred when the first nine participants were using the stylus pen; no critical incidents were observed with the last six participants that used the touch screen. Patients thought that the RAQ questions were easy to read and understand, but they found it difficult to initiate the questionnaire. Suggestions for improvement included improving aspects of the interface and navigation. The results of study 3 showed that most patients were able to understand and describe sections of the COPE sheet, and all considered discussing the information with their physicians. Suggestions for improvement included simplifying the language and improving the layout.</p> <p>Conclusions</p> <p>Findings from the three studies informed changes to the tool and confirmed the importance of usability testing on all end users to reduce errors, and as an important step in the development process of knowledge translation interventions.</p

    Rapidity and Centrality Dependence of Proton and Anti-proton Production from Au+Au Collisions at sqrt(sNN) = 130GeV

    Full text link
    We report on the rapidity and centrality dependence of proton and anti-proton transverse mass distributions from Au+Au collisions at sqrt(sNN) = 130GeV as measured by the STAR experiment at RHIC. Our results are from the rapidity and transverse momentum range of |y|<0.5 and 0.35 <p_t<1.00GeV/c. For both protons and anti-protons, transverse mass distributions become more convex from peripheral to central collisions demonstrating characteristics of collective expansion. The measured rapidity distributions and the mean transverse momenta versus rapidity are flat within |y|<0.5. Comparisons of our data with results from model calculations indicate that in order to obtain a consistent picture of the proton(anti-proton) yields and transverse mass distributions the possibility of pre-hadronic collective expansion may have to be taken into account.Comment: 4 pages, 3 figures, 1 table, submitted to PR

    Antidepressant Response in Major Depressive Disorder: A Meta-Regression Comparison of Randomized Controlled Trials and Observational Studies

    Get PDF
    To compare response to antidepressants between randomized controlled trials (RCTs) and observational trials.Published and unpublished studies (from 1989 to 2009) were searched for by 2 reviewers on Medline, the Cochrane library, Embase, clinicaltrials.gov, Current Controlled Trial, bibliographies and by mailing key organisations and researchers. RCTs and observational studies on fluoxetine or venlafaxine in first-line treatment for major depressive disorder reported in English, French or Spanish language were included in the main analysis. Studies including patients from a wider spectrum of depressive disorders (anxious depression, minor depressive episode, dysthymia) were added in a second analysis. The main outcome was the pre-/post-treatment difference on depression scales standardised to 100 (17-item or 21-item Hamilton Rating Scale for Depression or Montgomery and Åsberg Rating Scale) in each study arm. A meta-regression was conducted to adjust the comparison between observational studies and RCTs on treatment type, study characteristics and average patient characteristics. 12 observational studies and 109 RCTs involving 6757 and 11035 patients in 12 and 149 arms were included in the main analysis. Meta-regression showed that the standardised treatment response in RCTs is greater by a magnitude of 4.59 (2.61 to 6.56). Study characteristics were related to standardised treatment response, positively (study duration, number of follow-up assessments, outpatients versus inpatients, per protocol analysis versus intention to treat analysis) or negatively (blinded design, placebo design). At patient level, response increased with baseline severity and decreased with age. Results of the second analysis were consistent with this.Response to antidepressants is greater in RCTs than in observational studies. Observational studies should be considered as a necessary complement to RCTs

    Prevention of catheter lumen occlusion with rT-PA versus heparin (Pre-CLOT): study protocol of a randomized trial [ISRCTN35253449]

    Get PDF
    BACKGROUND: Many patients with end-stage renal disease use a central venous catheter for hemodialysis access. A large majority of these catheters malfunction within one year of insertion, with up to two-thirds due to thrombosis. The optimal solution for locking the catheter between hemodialysis sessions, to decrease the risk of thrombosis and catheter malfunction, is unknown. The Prevention of Catheter Lumen Occlusion with rt-PA versus Heparin (PreCLOT) study will determine if use of weekly rt-PA, compared to regular heparin, as a catheter locking solution, will decrease the risk of catheter malfunction. METHODS/DESIGN: The study population will consist of patients requiring chronic hemodialysis thrice weekly who are dialyzed with a newly inserted permanent dual-lumen central venous catheter. Patients randomized to the treatment arm will receive rt-PA 1 mg per lumen once per week, with heparin 5,000 units per ml as a catheter locking solution for the remaining two sessions. Patients randomized to the control arm will receive heparin 5,000 units per ml as a catheter locking solution after each dialysis session. The study treatment period will be six months, with 340 patients to be recruited from 14 sites across Canada. The primary outcome will be catheter malfunction, based on mean blood flow parameters while on hemodialysis, with a secondary outcome of catheter-related bacteremia. A cost-effectiveness analysis will be undertaken to assess the cost of maintaining a catheter using rt-PA as a locking solution, compared to the use of heparin. DISCUSSION: Results from this study will determine if use of weekly rt-PA, compared to heparin, will decrease catheter malfunction, as well as assess the cost-effectiveness of these locking solutions

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore