874 research outputs found

    The Use of Graphitic Carbon Nitride Based Composite Anodes for Lithium-Ion Battery Applications

    Get PDF
    Graphitic carbon nitride (gCN) is shown to undergo lithium insertion reactions applicable with lithium-ion battery anodes. Lithium capacity was found to be substantially lower than theoretically expected, so the properties of gCN composited with conducting graphite (CG), which was added to improve the performance, were investigated. The electrodes exhibited a systematic increase in lithium uptake with CG content, but the capacity never exceeded that of graphite. It is shown that electron transport via conducting pathways was limiting. Li+ uptake for 10 % gCN was similar to a graphite electrode, indicating that gCN does play a role in determining the storage capacity

    One-Step Synthesis, Structure, and Band Gap Properties of SnO2 Nanoparticles Made by a Low Temperature Nonaqueous Sol–Gel Technique

    Get PDF
    American Chemical Society. Because of its electrically conducting properties combined with excellent thermal stability and transparency throughout the visible spectrum, tin oxide (SnO2) is extremely attractive as a transparent conducting material for applications in low-emission window coatings and solar cells, as well as in lithium-ion batteries and gas sensors. It is also an important catalyst and catalyst support for oxidation reactions. Here, we describe a novel nonaqueous sol-gel synthesis approach to produce tin oxide nanoparticles (NPs) with a low NP size dispersion. The success of this method lies in the nonhydrolytic pathway that involves the reaction between tin chloride and an oxygen donor, 1-hexanol, without the need for a surfactant or subsequent thermal treatment. This one-pot procedure is carried out at relatively low temperatures in the 160-260 °C range, compatible with coating processes on flexible plastic supports. The NP size distribution, shape, and dislocation density were studied by powder X-ray powder diffraction analyzed using the method of whole powder pattern modeling, as well as high-resolution transmission electron microscopy. The SnO2NPs were determined to have particle sizes between 3.4 and 7.7 nm. The reaction products were characterized using liquid-state13C and1H nuclear magnetic resonance (NMR) that confirmed the formation of dihexyl ether and 1-chlorohexane. The NPs were studied by a combination of13C,1H, and119Sn solid-state NMR as well as Fourier transform infrared (FTIR) and Raman spectroscopy. The13C SSNMR, FTIR, and Raman data showed the presence of organic species derived from the 1-hexanol reactant remaining within the samples. The optical absorption, studied using UV-visible spectroscopy, indicated that the band gap (Eg) shifted systematically to lower energy with decreasing NP sizes. This unusual result could be due to mechanical strains present within the smallest NPs perhaps associated with the organic ligands decorating the NP surface. As the size increased, we observed a correlation with an increased density of screw dislocations present within the NPs that could indicate relaxation of the stress. We suggest that this could provide a useful method for band gap control within SnO2NPs in the absence of chemical dopants

    Graphitic Carbon Nitride Materials for Energy Applications

    Get PDF
    Polymeric layered carbon nitrides were investigated for use as catalyst support materials for proton exchange membrane fuel cells (PEMFCs) and water electrolyzers (PEMWEs). Three different carbon nitride materials were prepared: a heptazine-based graphitic carbon nitride material (gCNM), poly (triazine) imide carbon nitride intercalated with LiCl component (PTI-Li+Cl-) and boron-doped graphitic carbon nitride (B-gCNM). Following accelerated corrosion testing, all graphitic carbon nitride materials were found to be more electrochemically stable compared to conventional carbon black (Vulcan XC-72R) with B-gCNM support showing the best stability. For the supported Pt, Pt/PTI-Li+Cl- exhibited the best durability with only 19% electrochemical surface area (ECSA) loss versus 36% for Pt/Vulcan. Superior methanol oxidation activity was observed for all gCNM supported Pt catalysts on the basis of the catalyst ECSA. Preliminary results on IrO2 supported on gCNM using a PEMWE cell revealed an enhancement in the charge-transfer resistance as the current density increases when compared to unsupported IrO2. This may be attributed to a higher active surface area of the catalyst nanoparticles on the gCNM support

    Diagnosis, Genetics, and Therapy of Short Stature in Children: A Growth Hormone Research Society International Perspective

    Get PDF
    The Growth Hormone Research Society (GRS) convened a Workshop in March 2019 to evaluate the diagnosis and therapy of short stature in children. Forty-six international experts participated at the invitation of GRS including clinicians, basic scientists, and representatives from regulatory agencies and the pharmaceutical industry. Following plenary presentations addressing the current diagnosis and therapy of short stature in children, breakout groups discussed questions produced in advance by the planning committee and reconvened to share the group reports. A writing team assembled one document that was subsequently discussed and revised by participants. Participants from regulatory agencies and pharmaceutical companies were not part of the writing process. Short stature is the most common reason for referral to the pediatric endocrinologist. History, physical examination, and auxology remain the most important methods for understanding the reasons for the short stature. While some long-standing topics of controversy continue to generate debate, including in whom, and how, to perform and interpret growth hormone stimulation tests, new research areas are changing the clinical landscape, such as the genetics of short stature, selection of patients for genetic testing, and interpretation of genetic tests in the clinical setting. What dose of growth hormone to start, how to adjust the dose, and how to identify and manage a suboptimal response are still topics to debate. Additional areas that are expected to transform the growth field include the development of long-acting growth hormone preparations and other new therapeutics and diagnostics that may increase adult height or aid in the diagnosis of growth hormone deficiency.info:eu-repo/semantics/publishedVersio

    Severity Assessment of Lower Respiratory Tract Infection in Malawi: Derivation of a Novel Index (SWAT-Bp) Which Outperforms CRB-65

    Get PDF
    OBJECTIVE: To assess the validity of CRB-65 (Confusion, Respiratory rate >30 breaths/min, BP<90/60 mmHg, age >65 years) as a pneumonia severity index in a Malawian hospital population, and determine whether an alternative score has greater accuracy in this setting. DESIGN: Forty three variables were prospectively recorded during the first 48 hours of admission in all patients admitted to Queen Elizabeth Central Hospital, Malawi, for management of lower respiratory tract infection over a two month period (N = 240). Calculation of sensitivity and specificity for CRB-65 in predicting mortality was followed by multivariate modeling to create a score with superior performance in this population. RESULTS: Median age 37, HIV prevalence 79.9%, overall mortality 18.3%. CRB-65 predicted mortality poorly, indicated by the area under the ROC curve of 0.649. Independent predictors of death were: Male sex, “S” (AOR 2.6); Wasting, “W” (AOR 6.6); non-ambulatory, “A” (AOR 2.5); Temp >38°C or <35°C, “T” (AOR 3.2); BP<100/60, “Bp” (AOR 3.7). Combining these factors to form a severity index (SWAT-Bp) predicted mortality with high sensitivity and specificity (AUC: 0.867). Mortality for scores 0–5 was 0%, 3.3%, 7.4%, 29.2%, 61.5% and 87.5% respectively. A score ≥3 was 84% sensitive and 77% specific for mortality prediction, with a negative predictive value of 95.8%. CONCLUSION: CRB-65 performs poorly in this population. The SWAT-Bp score can accurately stratify patients; ≤2 indicates non-severe infection (mortality 4.4%) and ≥3 severe illness (mortality 45%)

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Measurement of the cross-section of high transverse momentum vector bosons reconstructed as single jets and studies of jet substructure in pp collisions at √s = 7 TeV with the ATLAS detector

    Get PDF
    This paper presents a measurement of the cross-section for high transverse momentum W and Z bosons produced in pp collisions and decaying to all-hadronic final states. The data used in the analysis were recorded by the ATLAS detector at the CERN Large Hadron Collider at a centre-of-mass energy of √s = 7 TeV;{\rm Te}{\rm V}andcorrespondtoanintegratedluminosityof and correspond to an integrated luminosity of 4.6\;{\rm f}{{{\rm b}}^{-1}}.ThemeasurementisperformedbyreconstructingtheboostedWorZbosonsinsinglejets.ThereconstructedjetmassisusedtoidentifytheWandZbosons,andajetsubstructuremethodbasedonenergyclusterinformationinthejetcentreofmassframeisusedtosuppressthelargemultijetbackground.ThecrosssectionforeventswithahadronicallydecayingWorZboson,withtransversemomentum. The measurement is performed by reconstructing the boosted W or Z bosons in single jets. The reconstructed jet mass is used to identify the W and Z bosons, and a jet substructure method based on energy cluster information in the jet centre-of-mass frame is used to suppress the large multi-jet background. The cross-section for events with a hadronically decaying W or Z boson, with transverse momentum {{p}_{{\rm T}}}\gt 320\;{\rm Ge}{\rm V}andpseudorapidity and pseudorapidity |\eta |\lt 1.9,ismeasuredtobe, is measured to be {{\sigma }_{W+Z}}=8.5\pm 1.7$ pb and is compared to next-to-leading-order calculations. The selected events are further used to study jet grooming techniques

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Tartrate-resistant acid phosphate as biomarker of bone turnover over the lifespan and different physiologic stages in sheep

    Get PDF
    Currently, the best resources for assessment of bone tissue using imaging techniques are expensive and available in few medical facilities, thus serum or urinary bone turnover biomarkers could be useful as early indicators of prognosis. However, there is a wide range of variability in bone turnover markers due to several factors, such as different ages and metabolic stages, thus it is important to have as much data published on the subject as possible. The aim of this study was therefore to generate a reference range for alkaline phosphatase (ALP) and tartrate-resistant acid phosphatase (TRAP) and validate the already published data.National Council for Scientific and Technological Development (CNPq - Brazil) PhD scholarship 202248/2015–1.info:eu-repo/semantics/publishedVersio
    corecore