520 research outputs found

    Stage at diagnosis for childhood solid cancers in Australia: A population-based study

    Get PDF
    BACKGROUND: Stage of cancer at diagnosis is one of the strongest predictors of survival and is essential for population cancer surveillance, comparison of cancer outcomes and to guide national cancer control strategies. Our aim was to describe, for the first time, the distribution of cases by stage at diagnosis and differences in stage-specific survival on a population basis for a range of childhood solid cancers in Australia. METHODS: The study cohort was drawn from the population-based Australian Childhood Cancer Registry and comprised children (<15 years) diagnosed with one of 12 solid malignancies between 2006 and 2014. Stage at diagnosis was assigned according to the Toronto Paediatric Cancer Stage Guidelines. Observed (all cause) survival was calculated using the Kaplan-Meier method, with follow-up on mortality available to 31 December 2015. RESULTS: Almost three-quarters (1256 of 1760 cases, 71%) of children in the study had localised or regional disease at diagnosis, varying from 43% for neuroblastoma to 99% for retinoblastoma. Differences in 5-year observed survival by stage were greatest for osteosarcoma (localised 85% (95% CI = 72%-93%) versus metastatic 37% (15%-59%)), neuroblastoma (localised 98% (91%-99%) versus metastatic 60% (52%-67%)), rhabdomyosarcoma (localised 85% (71%-93%) versus metastatic 53% (34%-69%)), and medulloblastoma (localised 69% (61%-75%) versus metastases to spine 42% (27%-57%)). CONCLUSION: The stage-specific information presented here provides a basis for comparison with other international population cancer registries. Understanding variations in survival by stage at diagnosis will help with the targeted formation of initiatives to improve outcomes for children with cancer

    Estadificación del cáncer infantil para registros de base poblacional

    Get PDF
    La recogida de información internacional fiable sobre estadificación de cáncer infantil por los registros de cáncer de base poblacional es esencial para el análisis epidemiológico y la realización de comparaciones evaluativas internacionales explicativas de la incidencia y los resultados asistenciales. En 2014 la Unión International Contra el Cáncer (UICC), el Dana-Farber Cancer Institute y el Hospital for Sick Children de Toronto, convocaron una reunión de consenso para abordar la ausencia de información consistente en la estadificación del cáncer infantil en los registros de cáncer poblacionales. Para cada subconjunto de los grupos/subgrupos diagnósticos mayores de cáncer infantil, en la reunión fueron revisados todos los sistemas de estadificación específicos de cada enfermedad utilizados habitualmente y se recomendó el más adecuado para utilizar en los registros de cáncer de base poblacional. Los sistemas de estadificación recomendados están enumerados como Guías de Toronto para la Estadificación del Cáncer Pediátrico. Las Guías recomiendan sistemas de estadificación específicos para la Leucemia Linfoblástica Aguda, Leucemia Mieloblástica Aguda, Linfoma de Hodgkin, Linfoma no-Hodgkin, Neuroblastoma, Tumor de Wilms, Rabdomiosarcoma, Sarcomas de Tejidos Blandos no-Rabdomiosarcoma, Osteosarcoma, Sarcoma de Ewing, Retinoblastoma, Hepatoblastoma, Tumor de Células Germinales (Cáncer Testicular y Ovárico), Meduloblastoma y Ependimoma. En este texto se proporcionan descripciones detalladas de los sistemas de estadificación recomendados en las Guías, para ayudar a los registros poblacionales de cáncer a recoger información internacionalmente consistente y comparable sobre el estadio del cáncer infantil al diagnóstico utilizando los documentos clínicos disponibles. La viabilidad y validez de estas Guías se ha evaluado con éxito en la práctica2. Están avaladas por el proyecto Factores pronósticos TNM de la UICC y publicadas en la Clasificación TNM de los Tumores Malignos UICC 8ª edición

    Mineral maturity and crystallinity index are distinct characteristics of bone mineral

    Get PDF
    The purpose of this study was to test the hypothesis that mineral maturity and crystallinity index are two different characteristics of bone mineral. To this end, Fourier transform infrared microspectroscopy (FTIRM) was used. To test our hypothesis, synthetic apatites and human bone samples were used for the validation of the two parameters using FTIRM. Iliac crest samples from seven human controls and two with skeletal fluorosis were analyzed at the bone structural unit (BSU) level by FTIRM on sections 2–4 lm thick. Mineral maturity and crystallinity index were highly correlated in synthetic apatites but poorly correlated in normal human bone. In skeletal fluorosis, crystallinity index was increased and maturity decreased, supporting the fact of separate measurement of these two parameters. Moreover, results obtained in fluorosis suggested that mineral characteristics can be modified independently of bone remodeling. In conclusion, mineral maturity and crystallinity index are two different parameters measured separately by FTIRM and offering new perspectives to assess bone mineral traits in osteoporosis

    Asteroseismology and Interferometry

    Get PDF
    Asteroseismology provides us with a unique opportunity to improve our understanding of stellar structure and evolution. Recent developments, including the first systematic studies of solar-like pulsators, have boosted the impact of this field of research within Astrophysics and have led to a significant increase in the size of the research community. In the present paper we start by reviewing the basic observational and theoretical properties of classical and solar-like pulsators and present results from some of the most recent and outstanding studies of these stars. We centre our review on those classes of pulsators for which interferometric studies are expected to provide a significant input. We discuss current limitations to asteroseismic studies, including difficulties in mode identification and in the accurate determination of global parameters of pulsating stars, and, after a brief review of those aspects of interferometry that are most relevant in this context, anticipate how interferometric observations may contribute to overcome these limitations. Moreover, we present results of recent pilot studies of pulsating stars involving both asteroseismic and interferometric constraints and look into the future, summarizing ongoing efforts concerning the development of future instruments and satellite missions which are expected to have an impact in this field of research.Comment: Version as published in The Astronomy and Astrophysics Review, Volume 14, Issue 3-4, pp. 217-36

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter

    Compressed representation of a partially defined integer function over multiple arguments

    Get PDF
    In OLAP (OnLine Analitical Processing) data are analysed in an n-dimensional cube. The cube may be represented as a partially defined function over n arguments. Considering that often the function is not defined everywhere, we ask: is there a known way of representing the function or the points in which it is defined, in a more compact manner than the trivial one

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore