761 research outputs found

    A transcription factor contributes to pathogenesis and virulence in streptococcus pneumoniae

    Get PDF
    To date, the role of transcription factors (TFs) in the progression of disease for many pathogens is yet to be studied in detail. This is probably due to transient, and generally low expression levels of TFs, which are the central components controlling the expression of many genes during the course of infection. However, a small change in the expression or specificity of a TF can radically alter gene expression. In this study, we combined a number of quality-based selection strategies including structural prediction of modulated genes, gene ontology and network analysis, to predict the regulatory mechanisms underlying pathogenesis of Streptococcus pneumoniae (the pneumococcus). We have identified two TFs (SP_0676 and SP_0927 [SmrC]) that might control tissue-specific gene expression during pneumococcal translocation from the nasopharynx to lungs, to blood and then to brain of mice. Targeted mutagenesis and mouse models of infection confirmed the role of SP_0927 in pathogenesis and virulence, and suggests that SP_0676 might be essential to pneumococcal viability. These findings provide fundamental new insights into virulence gene expression and regulation during pathogenesis.Layla K. Mahdi, Esmaeil Ebrahimie, David L. Adelson, James C. Paton, Abiodun D. Ogunniy

    SPECIAL ISSUE HIV and CHRONIC PAIN (The Global Task Force for Chronic Pain in People with HIV (PWH): Developing a research agenda in an emerging field)

    Get PDF
    Chronic pain is a common comorbidity in people with HIV (PWH), with prevalence estimates of 25-85%. Research in this area is growing, but significant gaps remain. A Global Task Force of HIV experts was organized to brainstorm a scientific agenda and identify measurement domains critical to advancing research in this field. Experts were identified through literature searches and snowball sampling. Two online questionnaires were developed by Task Force members. Questionnaire 1 asked participants to identify knowledge gaps in the field of HIV and chronic pain and identify measurement domains in studies of chronic pain in PWH. Responses were ranked in order of importance in Questionnaire 2, which was followed by a group discussion. 29 experts completed Questionnaire 1, 25 completed Questionnaire 2, and 21 participated in the group. Many important clinical and research priorities emerged, including the need to examine etiologies of chronic pain in PWH. Pain-related measurement domains were discussed, with a primary focus on domains that could be assessed in a standardized manner across various cohorts that include PWH in different countries. We collaboratively identified clinical and research priorities, as well as gaps in standardization of measurement domains, that can be used to move the field forward

    Pediatricians' weight assessment and obesity management practices

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Clinician adherence to obesity screening guidelines from United States health agencies remains suboptimal. This study explored how personal and career demographics influence pediatricians' weight assessment and management practices.</p> <p>Methods</p> <p>A web-based survey was distributed to U.S. pediatricians. Respondents were asked to identify the weight status of photographed children and about their weight assessment and management practices. Associations between career and personal demographic variables and pediatricians' weight perceptions, weight assessment and management practices were evaluated using univariate and multivariate modeling.</p> <p>Results</p> <p>3,633 pediatric medical providers correctly identified the weight status of children at a median rate of 58%. The majority of pediatric clinicians were white, female, and of normal weight status with more than 10 years clinical experience. Experienced pediatric medical providers were less likely than younger colleagues to correctly identify the weight status of pictured children and were also less likely to know and use BMI criteria for assessing weight status. General pediatricians were more likely than subspecialty practitioners to provide diverse interventions for weight management. Non-white and Hispanic general practitioners were more likely than counterparts to consider cultural approaches to weight management.</p> <p>Conclusion</p> <p>Pediatricians' perceptions of children's weight and their weight assessment and management practices are influenced by career and personal characteristics. Objective criteria and clinical guidelines should be uniformly applied by pediatricians to screen for and manage pediatric obesity.</p

    Is there a role of statins in the prevention of aortic biological prostheses degeneration

    Get PDF
    It has been recently observed that statins might slow the progression of aortic stenosis or sclerosis. Preliminary reports suggested a similar positive effect in reducing the degeneration of aortic valve bioprostheses even though this hypothesis should be further proven and supported by new data. In this review the present evidences of the possible effects of statins in this field are discussed

    Power to identify a genetic predictor of antihypertensive drug response using different methods to measure blood pressure response

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To determine whether office, home, ambulatory daytime and nighttime blood pressure (BP) responses to antihypertensive drug therapy measure the same signal and which method provides greatest power to identify genetic predictors of BP response.</p> <p>Methods</p> <p>We analyzed office, home, ambulatory daytime and nighttime BP responses in hypertensive adults randomized to atenolol (N = 242) or hydrochlorothiazide (N = 257) in the Pharmacogenomic Evaluation of Antihypertensive Responses Study. Since different measured BP responses may have different predictors, we tested the "same signal" model by using linear regression methods to determine whether known predictors of BP response depend on the method of BP measurement. We estimated signal-to-noise ratios and compared power to identify a genetic polymorphism predicting BP response measured by each method separately and by weighted averages of multiple methods.</p> <p>Results</p> <p>After adjustment for pretreatment BP level, known predictors of BP response including plasma renin activity, race, and sex were independent of the method of BP measurement. Signal-to-noise ratios were more than 2-fold greater for home and ambulatory daytime BP responses than for office and ambulatory nighttime BP responses and up to 11-fold greater for weighted averages of all four methods. Power to identify a genetic polymorphism predicting BP response was directly related to the signal-to-noise ratio and, therefore, greatest with the weighted averages.</p> <p>Conclusion</p> <p>Since different methods of measuring BP response to antihypertensive drug therapy measure the same signal, weighted averages of the BP responses measured by multiple methods minimize measurement error and optimize power to identify genetic predictors of BP response.</p

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore