130 research outputs found

    Fatigue performance of endodontically treated molars restored with different dentin replacement materials

    Get PDF
    OBJECTIVES: The aim was to investigate the fatigue performance of endodontically treated (ET) molars restored by various dentin-replacing materials and material configurations. Moreover, the impact of additional adhesive treatment with glass-ionomer cement (GIC) was evaluated.; METHODS: 250 intact molars were collected and randomly distributed into ten groups (n=25). After endodontic procedure standard Class I cavities were prepared and restored with different direct restorative techniques and dentin-replacing materials. Two-group were restored with either packable or flowable short fiber-reinforced composites (SFRCs). Two-group were restored by experimental fiber-reinforced GIC with and without adhesive treatment. Four-group were restored by conventional and resin-modified GICs with or without adhesive treatment. One-group was restored with a dual-cure composite resin and last group was restored with only conventional composite resin (control). Fatigue-survival was measured for all specimens using a cyclic-loading machine until fracture occurred or a number of 40.000 cycles were achieved. Kaplan-Meyer survival analysis was conducted, followed by pairwise log-rank post hoc comparisons. Fracture mode was then examined by means of optical microscopy and SEM.; RESULTS: Group restored with flowable SFRC showed significantly higher survival (p0.05). Group restored with fiber-reinforced GIC had significantly (p<0.05) higher survival rates compared to other commercial GICs. SEM demonstrated change of the fracture line when fracture reached the SFRC layer.; SIGNIFICANCE: Direct restoration of Class I in ET molars with the use of SFRCs as dentin-replacing materials demonstrated its ability to reinforce the dental structures and to increase the fatigue resistance in this specific clinical situation. Copyright © 2022 The Authors. Published by Elsevier Inc. All rights reserved

    Fracture Resistance and Microleakage around Direct Restorations in High C-Factor Cavities

    Get PDF
    The aim of this research was to evaluate the mechanical impact of different direct restorations in terms of fracture resistance, and subsequent fracture pattern, in occlusal high C-factor cavities. Furthermore, the adaptation of different direct restorations in the form of gap formation was also evaluated. Seventy-two intact mandibular molars were collected and randomly distributed into three groups (n = 24). Class I occlusal cavities with standardized dimensions were prepared in all specimens. After adhesive treatment, the cavities were restored with direct restorations utilizing three different materials. Group 1: layered conventional packable resin composite (Filtek Ultimate), Group 2: bulk-fill resin composite (SDR), Group 3: bulk-fill short fibre-reinforced composite (SFRC; everX Posterior) covered with packable composite occlusally. Half of the restored specimens underwent static load-to fracture testing (n = 12/group), while the rest underwent sectioning and staining for microleakage evaluation and gap formation analysis. Fracture patterns were evaluated visually among the mechanically tested specimens. The layered composite restoration (Group 1) showed significantly lower fracture resistance compared to the bulk fill groups (Group 2, p = 0.005, Group 3, p = 0.008), while there was no difference in fracture resistance between the other groups. In terms of gap formation values, the layered composite restoration (Group 1) produced significantly higher gap formation compared to the bulk-fill groups (Group 2, p = 0.000, Group 3, p = 0.000). Regarding the fracture pattern, SFRC (Group 3) produced the highest number, while SDR (Group 2) produced the lowest number of repairable fractures. The use of bulk-fill resin composite (fibre or non-fibre-reinforced) for occlusal direct restorations in high C-factor cavities showed promising achievements regarding both fracture resistance and microleakage. Furthermore, the use of short fibre-reinforced bulk-fill composite can also improve the fracture pattern of the restoration-tooth unit. Bulk-fill materials provide a simple and effective solution for restoring and reinforcing high C-factor occlusal cavities

    Fatigue performance of endodontically treated molars restored with different dentin replacement materials

    Get PDF
    OBJECTIVES: The aim was to investigate the fatigue performance of endodontically treated (ET) molars restored by various dentin-replacing materials and material configurations. Moreover, the impact of additional adhesive treatment with glass-ionomer cement (GIC) was evaluated.; METHODS: 250 intact molars were collected and randomly distributed into ten groups (n=25). After endodontic procedure standard Class I cavities were prepared and restored with different direct restorative techniques and dentin-replacing materials. Two-group were restored with either packable or flowable short fiber-reinforced composites (SFRCs). Two-group were restored by experimental fiber-reinforced GIC with and without adhesive treatment. Four-group were restored by conventional and resin-modified GICs with or without adhesive treatment. One-group was restored with a dual-cure composite resin and last group was restored with only conventional composite resin (control). Fatigue-survival was measured for all specimens using a cyclic-loading machine until fracture occurred or a number of 40.000 cycles were achieved. Kaplan-Meyer survival analysis was conducted, followed by pairwise log-rank post hoc comparisons. Fracture mode was then examined by means of optical microscopy and SEM.; RESULTS: Group restored with flowable SFRC showed significantly higher survival (p0.05). Group restored with fiber-reinforced GIC had significantly (p<0.05) higher survival rates compared to other commercial GICs. SEM demonstrated change of the fracture line when fracture reached the SFRC layer.; SIGNIFICANCE: Direct restoration of Class I in ET molars with the use of SFRCs as dentin-replacing materials demonstrated its ability to reinforce the dental structures and to increase the fatigue resistance in this specific clinical situation. Copyright © 2022 The Authors. Published by Elsevier Inc. All rights reserved

    Azimuthal anisotropy of charged jet production in root s(NN)=2.76 TeV Pb-Pb collisions

    Get PDF
    We present measurements of the azimuthal dependence of charged jet production in central and semi-central root s(NN) = 2.76 TeV Pb-Pb collisions with respect to the second harmonic event plane, quantified as nu(ch)(2) (jet). Jet finding is performed employing the anti-k(T) algorithm with a resolution parameter R = 0.2 using charged tracks from the ALICE tracking system. The contribution of the azimuthal anisotropy of the underlying event is taken into account event-by-event. The remaining (statistical) region-to-region fluctuations are removed on an ensemble basis by unfolding the jet spectra for different event plane orientations independently. Significant non-zero nu(ch)(2) (jet) is observed in semi-central collisions (30-50% centrality) for 20 <p(T)(ch) (jet) <90 GeV/c. The azimuthal dependence of the charged jet production is similar to the dependence observed for jets comprising both charged and neutral fragments, and compatible with measurements of the nu(2) of single charged particles at high p(T). Good agreement between the data and predictions from JEWEL, an event generator simulating parton shower evolution in the presence of a dense QCD medium, is found in semi-central collisions. (C) 2015 CERN for the benefit of the ALICE Collaboration. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).Peer reviewe

    Long-range angular correlations on the near and away side in p&#8211;Pb collisions at

    Get PDF

    Forward-central two-particle correlations in p-Pb collisions at root s(NN)=5.02 TeV

    Get PDF
    Two-particle angular correlations between trigger particles in the forward pseudorapidity range (2.5 2GeV/c. (C) 2015 CERN for the benefit of the ALICE Collaboration. Published by Elsevier B. V.Peer reviewe

    Event-shape engineering for inclusive spectra and elliptic flow in Pb-Pb collisions at root(NN)-N-S=2.76 TeV

    Get PDF
    Peer reviewe

    Pseudorapidity and transverse-momentum distributions of charged particles in proton-proton collisions at root s=13 TeV

    Get PDF
    The pseudorapidity (eta) and transverse-momentum (p(T)) distributions of charged particles produced in proton-proton collisions are measured at the centre-of-mass energy root s = 13 TeV. The pseudorapidity distribution in vertical bar eta vertical bar <1.8 is reported for inelastic events and for events with at least one charged particle in vertical bar eta vertical bar <1. The pseudorapidity density of charged particles produced in the pseudorapidity region vertical bar eta vertical bar <0.5 is 5.31 +/- 0.18 and 6.46 +/- 0.19 for the two event classes, respectively. The transverse-momentum distribution of charged particles is measured in the range 0.15 <p(T) <20 GeV/c and vertical bar eta vertical bar <0.8 for events with at least one charged particle in vertical bar eta vertical bar <1. The evolution of the transverse momentum spectra of charged particles is also investigated as a function of event multiplicity. The results are compared with calculations from PYTHIA and EPOS Monte Carlo generators. (C) 2015 CERN for the benefit of the ALICE Collaboration. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).Peer reviewe

    Elliptic flow of muons from heavy-flavour hadron decays at forward rapidity in Pb-Pb collisions at root s(NN)=2.76TeV

    Get PDF
    The elliptic flow, v(2), of muons from heavy-flavour hadron decays at forward rapidity (2.5 <y <4) is measured in Pb-Pb collisions at root s(NN)= 2.76TeVwith the ALICE detector at the LHC. The scalar product, two- and four-particle Q cumulants and Lee-Yang zeros methods are used. The dependence of the v(2) of muons from heavy-flavour hadron decays on the collision centrality, in the range 0-40%, and on transverse momentum, p(T), is studied in the interval 3 <p(T)<10 GeV/c. A positive v(2) is observed with the scalar product and two-particle Q cumulants in semi-central collisions (10-20% and 20-40% centrality classes) for the p(T) interval from 3 to about 5GeV/c with a significance larger than 3 sigma, based on the combination of statistical and systematic uncertainties. The v(2) magnitude tends to decrease towards more central collisions and with increasing pT. It becomes compatible with zero in the interval 6 <p(T)<10 GeV/c. The results are compared to models describing the interaction of heavy quarks and open heavy-flavour hadrons with the high-density medium formed in high-energy heavy-ion collisions. (C) 2015 CERN for the benefit of the ALICE Collaboration. Published by Elsevier B.V.Peer reviewe
    corecore