79 research outputs found

    Effect of guidewire on contribution of loss due to momentum change and viscous loss to the translesional pressure drop across coronary artery stenosis: An analytical approach

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Guidewire (GW) size and stenosis dimensions are the two major factors affecting the translesional pressure drop. Studying the combined effect of these parameters on the mean pressure drop (Δ<it>p</it>) across the stenosis is of high practical importance.</p> <p>Methods</p> <p>In this study, time averaged mass and momentum conservation equations are solved analytically to obtain pressure drop-flow, Δ<it>p</it>-<it>Q</it>, curves for three different percentage area blockages corresponding to moderate (64%), intermediate (80%), and severe (90%) stenoses. Stenosis is considered to be axisymmetric consisting of three different sections namely converging, throat, and diverging regions. Analytical expressions for pressure drop are obtained for each of these regions separately. Using this approach, effects of lesion length and GW insertion on the mean translesional pressure drop and its component (loss due to momentum change and viscous loss) are analyzed.</p> <p>Results and Conclusion</p> <p>It is observed that for a given percent area stenosis (AS), increase in the throat length only increases the viscous loss. However, increase in the severity of stenosis and GW insertion increase both loss due to momentum change and viscous loss. GW insertion has greater contribution to the rise in viscous loss (increase by 2.14 and 2.72 times for 64% and 90% AS, respectively) than loss due to momentum change (1.34% increase for 64% AS and 25% decrease for 90% AS). It also alters the hyperemic pressure drop in moderate (48% increase) to intermediate (30% increase) stenoses significantly. However, in severe stenoses GW insertion has a negligible effect (0.5% increase) on hyperemic translesional pressure drop. It is also observed that pressure drop in a severe stenosis is less sensitive to lesion length variation (4% and 14% increase in Δ<it>p </it>for without and with GW, respectively) as compared to intermediate (10% and 30% increase in Δ<it>p </it>for without and with GW, respectively) and moderate stenoses (22% and 48% increase in Δ<it>p </it>for without and with GW, respectively). Based on the contribution of pressure drop components to the total translesional pressure drop, it is found that viscous losses are dominant in moderate stenoses, while in severe stenoses losses due to momentum changes are significant. It is also shown that this simple analytical solution can provide valuable information regarding interpretation of coronary diagnostic parameters such as fractional flow reserve (FFR).</p

    In vitro Quantification of Guidewire Flow-Obstruction Effect in MODEL CORONARY STENOSES FOR INTERVENTIONAL DIAGNOSTIC PROCEDURE

    Get PDF
    The objective is to quantify the guidewire ( and preangioplasty). The diagnostic parameters measured before guidewire insertion (CFR and FFR) and during guidewire insertion (gCFR and gFFR) were validated numerically and correlated with the new diagnostic parameter &quot;lesion flow coefficient (LFC).&quot; There was significant flow reduction with increased trans-stenotic pressure drop due to guidewire insertion. The FFR-gFFR and CFR-gCFR correlations wer

    Robotic-assisted ultrasound for fetal imaging: Evolution from single-arm to dual-arm system

    Get PDF
    © Springer Nature Switzerland AG 2019. The development of robotic-assisted extracorporeal ultrasound systems has a long history and a number of projects have been proposed since the 1990s focusing on different technical aspects. These aim to resolve the deficiencies of on-site manual manipulation of hand-held ultrasound probes. This paper presents the recent ongoing developments of a series of bespoke robotic systems, including both single-arm and dual-arm versions, for a project known as intelligent Fetal Imaging and Diagnosis (iFIND). After a brief review of the development history of the extracorporeal ultrasound robotic system used for fetal and abdominal examinations, the specific aim of the iFIND robots, the design evolution, the implementation details of each version, and the initial clinical feedback of the iFIND robot series are presented. Based on the preliminary testing of these newly-proposed robots on 42 volunteers, the successful and reliable working of the mechatronic systems were validated. Analysis of a participant questionnaire indicates a comfortable scanning experience for the volunteers and a good acceptance rate to being scanned by the robots

    Jet size dependence of single jet suppression in lead-lead collisions at sqrt(s(NN)) = 2.76 TeV with the ATLAS detector at the LHC

    Get PDF
    Measurements of inclusive jet suppression in heavy ion collisions at the LHC provide direct sensitivity to the physics of jet quenching. In a sample of lead-lead collisions at sqrt(s) = 2.76 TeV corresponding to an integrated luminosity of approximately 7 inverse microbarns, ATLAS has measured jets with a calorimeter over the pseudorapidity interval |eta| < 2.1 and over the transverse momentum range 38 < pT < 210 GeV. Jets were reconstructed using the anti-kt algorithm with values for the distance parameter that determines the nominal jet radius of R = 0.2, 0.3, 0.4 and 0.5. The centrality dependence of the jet yield is characterized by the jet "central-to-peripheral ratio," Rcp. Jet production is found to be suppressed by approximately a factor of two in the 10% most central collisions relative to peripheral collisions. Rcp varies smoothly with centrality as characterized by the number of participating nucleons. The observed suppression is only weakly dependent on jet radius and transverse momentum. These results provide the first direct measurement of inclusive jet suppression in heavy ion collisions and complement previous measurements of dijet transverse energy imbalance at the LHC.Comment: 15 pages plus author list (30 pages total), 8 figures, 2 tables, submitted to Physics Letters B. All figures including auxiliary figures are available at http://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/HION-2011-02

    Physician-assisted suicide: a review of the literature concerning practical and clinical implications for UK doctors

    Get PDF
    BACKGROUND: A bill to legalize physician-assisted suicide in the UK recently made significant progress in the British House of Lords and will be reintroduced in the future. Until now there has been little discussion of the clinical implications of physician-assisted suicide for the UK. This paper describes problematical issues that became apparent from a review of the medical and psychiatric literature as to the potential effects of legalized physician-assisted suicide. DISCUSSION: Most deaths by physician-assisted suicide are likely to occur for the illness of cancer and in the elderly. GPs will deal with most requests for assisted suicide. The UK is likely to have proportionately more PAS deaths than Oregon due to the bill's wider application to individuals with more severe physical disabilities. Evidence from other countries has shown that coercion and unconscious motivations on the part of patients and doctors in the form of transference and countertransference contribute to the misapplication of physician-assisted suicide. Depression influences requests for hastened death in terminally ill patients, but is often under-recognized or dismissed by doctors, some of whom proceed with assisted death anyway. Psychiatric evaluations, though helpful, do not solve these problems. Safeguards that are incorporated into physician-assisted suicide criteria probably decrease but do not prevent its misapplication. SUMMARY: The UK is likely to face significant clinical problems arising from physician-assisted suicide if it is legalized. Terminally ill patients with mental illness, especially depression, are particularly vulnerable to the misapplication of physician-assisted suicide despite guidelines and safeguards

    GABAergic regulation of cerebellar NG2 cell development is altered in perinatal white matter injury.

    Get PDF
    Diffuse white matter injury (DWMI), a leading cause of neurodevelopmental disabilities in preterm infants, is characterized by reduced oligodendrocyte formation. NG2-expressing oligodendrocyte precursor cells (NG2 cells) are exposed to various extrinsic regulatory signals, including the neurotransmitter GABA. We investigated GABAergic signaling to cerebellar white matter NG2 cells in a mouse model of DWMI (chronic neonatal hypoxia). We found that hypoxia caused a loss of GABAA receptor-mediated synaptic input to NG2 cells, extensive proliferation of these cells and delayed oligodendrocyte maturation, leading to dysmyelination. Treatment of control mice with a GABAA receptor antagonist or deletion of the chloride-accumulating transporter NKCC1 mimicked the effects of hypoxia. Conversely, blockade of GABA catabolism or GABA uptake reduced NG2 cell numbers and increased the formation of mature oligodendrocytes both in control and hypoxic mice. Our results indicate that GABAergic signaling regulates NG2 cell differentiation and proliferation in vivo, and suggest that its perturbation is a key factor in DWMI

    ICAR: endoscopic skull‐base surgery

    Get PDF
    n/

    Non-isothermal Laminar Flow of Gases through Cooled Tubes

    No full text

    Numerical Approximation of the Convective Boundary Condition

    No full text

    Experimental investigation of flow and heating in a resonance tube

    No full text
    • 

    corecore