8 research outputs found

    Development and validation of a novel image quality rating scale for echocardiography during cardiac arrest

    Get PDF
    Objective: Research into echocardiography (echo) during cardiac arrest has suffered from methodological flaws that limit aggregation of findings. We developed and validated a novel image rating scale for qualitative analysis of echo images obtained during resuscitation. Methods: A novel 5-point ordinal rating scale was developed and validated using recorded echo images from 145 consecutive cardiac arrest patients. Recorded echo images were reviewed in a blinded fashion by investigators experienced in cardiac arrest echo, and image quality was rated using this scale. Cardiac activity was subsequently classified as no activity, disorganized activity and organized activity. The primary outcome was inter-rater agreement using the image quality rating scale. Secondary outcome was the qualitative evaluation of the type of cardiac activity. Results: A total of 235 ultrasounds were analyzed by study investigators using the image quality rating scale. The overall image quality agreement between reviewers using the scale was good with a weighted kappa of 0.65. Agreement for image quality in subxyphoid images was greater than in parasternal images (0.65-0.52). Echo analysis of cardiac activity showed no activity (33%), disorganized activity (18%), and organized activity (49%). Agreement was great for presence or absence of cardiac activity and organized cardiac activity with a kappa of 0.84 and 0.78. Conclusions: A novel image quality rating scale for echo during cardiac arrest demonstrates substantial agreement between reviewers. Agreement regarding the presence or absence, as well as the organization of cardiac activity was substantial

    Echocardiographic pre-pause imaging and identifying the acoustic window during CPR reduces CPR pause time during ACLS - A prospective Cohort Study

    Get PDF
    Objectives: Pre-pause imaging during cardiopulmonary resuscitation (CPR) involves the acquisition of poor-quality, brief images immediately prior to stopping CPR to allow shorter, better-quality images during the pause. We hypothesize that pre-pause imaging is associated with a decrease in CPR pause length and shorter image acquisition time. Methods: Prospective, interventional cohort study enrolling out-of-hospital (OOH) cardiac arrest patients. Pre-pause imaging involves pre-localizing of the approximate sonographic window during CPR to support subsequent fine tuning when CPR pauses. Physicians were educated on pre-pause imaging and data was recorded prior- and post- introduction of pre-pause imaging into American cardiac life support (ACLS). Timing of CPR pauses and identification of interventions and events during pause were recorded (e.g., intubation, defibrillation, multiple cardiac ultrasounds). Ultrasound (US) images were reviewed for image quality using a 5-point scale. Primary outcome was length of CPR pause with and without pre-pause imaging. Secondary outcome included US length. Results: One hundred and forty five subjects presenting after OOH cardiac arrest were enrolled over 13 months, 70 during the baseline period prior to pre-pause imaging and 75 after pre-pause imaging was integrated into ACLS. Pre-pause imaging decreased CPR pause length from 28.3 s (95%CI 25.1-31.5) to 12.8 s (95%CI 11.9-13.7). US image acquisition time decreased with pre-pause imaging from 20.4 (95%CI 18.0-22.7) to 11.0 s (95%CI 10.1-11.8). US image quality was unchanged despite the decrease in image acquisition time. (3.0 (95%CI 2.8-3.2) vs 2.7 (95%CI 2.5-2.9)). Multivariate modeling showed that ultrasound did not prolong CPR pause length. Conclusion: Pre-pause imaging was associated with significant decrease in CPR pause length and US image acquisition time. Pre-pause imaging should be encouraged for any clinicians who use ultrasound during ACLS

    Development of a novel observed structured clinical exam to assess clinical ultrasound proficiency in undergraduate medical education

    No full text
    Abstract Objectives A pilot study was performed to develop and test an observed structured clinical exam (OSCE) for clinical ultrasound in second-year medical students. The goal was to assess a longitudinal clinical ultrasound curriculum for medical students and to help determine readiness to perform ultrasound during clinical clerkships. Methods The OSCE contained 40 tasks over 30 min in a one-to-one examiner to examinee environment using standardized patients covering cardiac, pulmonary, and inferior vena cava (IVC) ultrasound exams along with 6 critical diagnoses. Examinees were assessed using a binary checklist approach. A two-way ANOVA analysis was performed to determine if there were differences between the day and session the OSCE was administered. Results are presented as mean ± standard deviation. Results One hundred fifty-two students were tested with an overall mean score of 64.9 ± 17.6%. Scores between the cardiac, IVC, and lung sections varied—67.8% ± 18.8%, 62.4% ± 26.2%, and 57.1% ± 20.6%, respectively. One hundred twenty-six (82.9%) answered at least one critical diagnosis incorrectly. Students in the late session performed better than the early session (1: 60% vs 2: 69%, p = .001). Conclusions Students performed better in later sessions. Additionally, the number of questions left blank at the end of the exam suggests that the length of the OSCE should be evaluated. Incorporating critical diagnoses was challenging for examinees. The proposed OSCE is a valuable assessment tool that could be adapted to assess student’s readiness to use clinical ultrasound prior to clerkships

    Adrenal Incidentaloma

    No full text
    An adrenal incidentaloma is now established as a common endocrine diagnosis that requires a multidisciplinary approach for effective management. The majority of patients can be reassured and discharged, but a personalized approach based upon image analysis, endocrine workup and clinical symptoms and signs are required in every case. ACC remains a real concern but is restricted to <2% of all cases. Functional AI lesions are commoner (but still probably <10% of total) and the greatest challenge remains the diagnosis and optimum management of autonomous cortisol secretion. Modern-day surgery has improved outcomes and novel radiological and urinary biomarkers will improve early detection and patient stratification in future years to come
    corecore