1,227 research outputs found

    Viriot: A cloud of things that offers iot infrastructures as a service

    Get PDF
    Many cloud providers offer IoT services that simplify the collection and processing of IoT information. However, the IoT infrastructure composed of sensors and actuators that produces this information remains outside the cloud; therefore, application developers must install, connect and manage the cloud. This requirement can be a market barrier, especially for small/medium software companies that cannot afford the infrastructural costs associated with it and would only prefer to focus on IoT application developments. Motivated by the wish to eliminate this barrier, this paper proposes a Cloud of Things platform, called VirIoT, which fully brings the Infrastructure as a service model typical of cloud computing to the world of Internet of Things. VirIoT provides users with virtual IoT infrastructures (Virtual Silos) composed of virtual things, with which users can interact through dedicated and standardized broker servers in which the technology can be chosen among those offered by the platform, such as oneM2M, NGSI and NGSI-LD. VirIoT allows developers to focus their efforts exclusively on IoT applications without worrying about infrastructure management and allows cloud providers to expand their IoT services portfolio. VirIoT uses external things and cloud/edge computing resources to deliver the IoT virtualization services. Its open-source architecture is microservice-based and runs on top of a distributed Kubernetes platform with nodes in central and edge data centers. The architecture is scalable, efficient and able to support the continuous integration of heterogeneous things and IoT standards, taking care of interoperability issues. Using a VirIoT deployment spanning data centers in Europe and Japan, we conducted a performance evaluation with a two-fold objective: showing the efficiency and scalability of the architecture; and leveraging VirIoT’s ability to integrate different IoT standards in order to make a fair comparison of some open-source IoT Broker implementations, namely Mobius for oneM2M, Orion for NGSIv2, Orion-LD and Scorpio for NGSI-LD

    Influence of shock wave propagation on dielectric barrier discharge plasma actuator performance

    Get PDF
    Interest in plasma actuators as active flow control devices is growing rapidly due to their lack of mechanical parts, light weight and high response frequency. Although the flow induced by these actuators has received much attention, the effect that the external flow has on the performance of the actuator itself must also be considered, especially the influence of unsteady high-speed flows which are fast becoming a norm in the operating flight envelopes. The primary objective of this study is to examine the characteristics of a dielectric barrier discharge (DBD) plasma actuator when exposed to an unsteady flow generated by a shock tube. This type of flow, which is often used in different studies, contains a range of flow regimes from sudden pressure and density changes to relatively uniform high-speed flow regions. A small circular shock tube is employed along with the schlieren photography technique to visualize the flow. The voltage and current traces of the plasma actuator are monitored throughout, and using the well-established shock tube theory the change in the actuator characteristics are related to the physical processes which occur inside the shock tube. The results show that not only is the shear layer outside of the shock tube affected by the plasma but the passage of the shock front and high-speed flow behind it also greatly influences the properties of the plasma

    Disrupted in schizophrenia 1 (DISC1) L100P mutants have impaired activity-dependent plasticity in vivo and in vitro

    Get PDF
    Major neuropsychiatric disorders are genetically complex but share overlapping etiology. Mice mutant for rare, highly penetrant risk variants can be useful in dissecting the molecular mechanisms involved. The gene disrupted in schizophrenia 1 (DISC1) has been associated with increased risk for neuropsychiatric conditions. Mice mutant for Disc1 display morphological, functional and behavioral deficits that are consistent with impairments observed across these disorders. Here we report that Disc1 L100P mutants are less able to reorganize cortical circuitry in response to stimulation in vivo. Molecular analysis reveals that the mutants have a reduced expression of PSD95 and pCREB in visual cortex and fail to adjust expression of such markers in response to altered stimulation. In vitro analysis shows that mutants have impaired functional reorganization of cortical neurons in response to selected forms of neuronal stimulation, but there is no altered basal expression of synaptic markers. These findings suggest that DISC1 has a critical role in the reorganization of cortical plasticity and that this phenotype becomes evident only under challenge, even at early postnatal stages. This result may represent an important etiological mechanism in the emergence of neuropsychiatric disorders

    Search for New Physics with Jets and Missing Transverse Momentum in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for new physics is presented based on an event signature of at least three jets accompanied by large missing transverse momentum, using a data sample corresponding to an integrated luminosity of 36 inverse picobarns collected in proton--proton collisions at sqrt(s)=7 TeV with the CMS detector at the LHC. No excess of events is observed above the expected standard model backgrounds, which are all estimated from the data. Exclusion limits are presented for the constrained minimal supersymmetric extension of the standard model. Cross section limits are also presented using simplified models with new particles decaying to an undetected particle and one or two jets

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Skin tribology: Science friction?

    Get PDF
    The application of tribological knowledge is not just restricted to optimizing mechanical and chemical engineering problems. In fact, effective solutions to friction and wear related questions can be found in our everyday life. An important part is related to skin tribology, as the human skin is frequently one of the interacting surfaces in relative motion. People seem to solve these problems related to skin friction based upon a trial-and-error strategy and based upon on our sense for touch. The question of course rises whether or not a trained tribologist would make different choices based upon a science based strategy? In other words: Is skin friction part of the larger knowledge base that has been generated during the last decades by tribology research groups and which could be referred to as Science Friction? This paper discusses the specific nature of tribological systems that include the human skin and argues that the living nature of skin limits the use of conventional methods. Skin tribology requires in vivo, subject and anatomical location specific test methods. Current predictive friction models can only partially be applied to predict in vivo skin friction. The reason for this is found in limited understanding of the contact mechanics at the asperity level of product-skin interactions. A recently developed model gives the building blocks for enhanced understanding of friction at the micro scale. Only largely simplified power law based equations are currently available as general engineering tools. Finally, the need for friction control is illustrated by elaborating on the role of skin friction on discomfort and comfort. Surface texturing and polymer brush coatings are promising directions as they provide way and means to tailor friction in sliding contacts without the need of major changes to the produc

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Development of quality indicators for monitoring outcomes of frail elderly hospitalised in acute care health settings: Study Protocol

    Get PDF
    Background: Frail older people admitted to acute care hospitals are at risk of a range of adverse outcomes, including geriatric syndromes, although targeted care strategies can improve health outcomes for these patients. It is therefore important to assess inter-hospital variation in performance in order to plan and resource improvement programs. Clinical quality outcome indicators provide a mechanism for identifying variation in performance over time and between hospitals, however to date there has been no routine use of such indicators in acute care settings. A barrier to using quality indicators is lack of access to routinely collected clinical data. The interRAI Acute Care (AC) assessment system supports comprehensive geriatric assessment of older people within routine daily practice in hospital and includes process and outcome data pertaining to geriatric syndromes. This paper reports the study protocol for the development of aged care quality indicators for acute care hospitals. Methods/Design. The study will be conducted in three phases:. 1. Development of a preliminary inclusive set of quality indicators set based on a literature review and expert panel consultation,. 2. A prospective field study including recruitment of 480 patients aged 70 years or older across 9 Australian hospitals. Each patient will be assessed on admission and discharge using the interRAI AC, and will undergo daily monitoring to observe outcomes. Medical records will be independently audited, and. 3. Analysis and compilation of a definitive quality indicator set, including two anonymous voting rounds for quality indicator inclusion by the expert panel. Discussion. The approach to quality indicators proposed in this protocol has four distinct advantages over previous efforts: the quality indicators focus on outcomes; they can be collected as part of a routinely applied clinical information and decision support system; the clinical data will be robust and will contribute to better understanding variations in hospital care of older patients; The quality indicators will have international relevance as they will be built on the interRAI assessment instrument, an internationally recognised clinical system
    • …
    corecore