298 research outputs found

    Subcooling for Long Duration In-Space Cryogenic Propellant Storage

    Get PDF
    Cryogenic propellants such as hydrogen and oxygen are crucial for exploration of the solar system because of their superior specific impulse capability. Future missions may require vehicles to remain in space for months, necessitating long-term storage of these cryogens. A Thermodynamic Cryogen Subcooler (TCS) can ease the challenge of cryogenic fluid storage by removing energy from the cryogenic propellant through isobaric subcooling of the cryogen below its normal boiling point prior to launch. The isobaric subcooling of the cryogenic propellant will be performed by using a cold pressurant to maintain the tank pressure while the cryogen's temperature is simultaneously reduced using the TCS. The TCS hardware will be integrated into the launch infrastructure and there will be no significant addition to the launched dry mass. Heat leaks into all cryogenic propellant tanks, despite the use of the best insulation systems. However, the large heat capacity available in the subcooled cryogenic propellants allows the energy that leaks into the tank to be absorbed until the cryogen reaches its operational thermodynamic condition. During this period of heating of the subcooled cryogen there will be minimal loss of the propellant due to venting for pressure control. This simple technique can extend the operational life of a spacecraft or an orbital cryogenic depot for months with minimal mass penalty. In fact isobaric subcooling can more than double the in-space hold time of liquid hydrogen compared to normal boiling point hydrogen. A TCS for cryogenic propellants would thus provide an enhanced level of mission flexibility. Advances in the important components of the TCS will be discussed in this paper

    Threefold rotational symmetry in hexagonally shaped core–shell (In,Ga)As/GaAs nanowires revealed by coherent X-ray diffraction imaging

    Get PDF
    Coherent X-ray diffraction imaging at symmetric hhh Bragg reflections was used to resolve the structure of GaAs/In0.15_{0.15}Ga0.85_{0.85}As/GaAs core–shell–shell nanowires grown on a silicon (111) substrate. Diffraction amplitudes in the vicinity of GaAs 111 and GaAs 333 reflections were used to reconstruct the lost phase information. It is demonstrated that the structure of the core–shell–shell nanowire can be identified by means of phase contrast. Interestingly, it is found that both scattered intensity in the (111) plane and the reconstructed scattering phase show an additional threefold symmetry superimposed with the shape function of the investigated hexagonal nanowires. In order to find the origin of this threefold symmetry, elasticity calculations were performed using the finite element method and subsequent kinematic diffraction simulations. These suggest that a non-hexagonal (In,Ga)As shell covering the hexagonal GaAs core might be responsible for the observation

    Synthesis of stoichiometrically controlled reactive aluminosilicate and calcium-aluminosilicate powders

    Get PDF
    Aluminosilicate and calcium-aluminosilicate powders are synthesised via an organic steric entrapment route under conditions permitting strict stoichiometric control, utilising polyvinyl alcohol and polyethylene glycol as polymeric carriers. Polyethylene glycol is superior to polyvinyl alcohol for synthesis of calcium-aluminosilicate powders via this method, producing a more controllable product which generated less fine ash during calcination. This paper presents detailed description of synthesis and characterisation of the powders produced through this approach, including new insight into the nanostructures within the calcined powders. Aluminium environments are a mixture of 4-, 5- and 6-coordinated, while silicon is tetrahedral and shows a broad range of connectivity states. The powders are X-ray amorphous, display a high degree of homogeneity, and thus offer potential for utilisation as precursors for synthesis of hydrous aluminosilicates in the quaternary CaO-Na2O-Al2O3-SiO2 system

    Defining the characteristics and expectations of fluid bolus therapy : A worldwide perspective

    Get PDF
    Purpose: The purpose of the study is to understand what clinicians believe defines fluid bolus therapy (FBT) and the expected response to such intervention. Methods: We asked intensive care specialists in 30 countries to participate in an electronic questionnaire of their practice, definition, and expectations of FBT. Results: We obtained 3138 responses. Despite much variation, more than 80% of respondents felt that more than 250 mL of either colloid or crystalloid fluid given over less than 30 minutes defined FBT, with crystalloids most acceptable. The most acceptable crystalloid and colloid for use as FBT were 0.9% saline and 4% albumin solution, respectively. Most respondents believed that one or more of the following physiological changes indicates a response to FBT: a mean arterial pressure increase greater than 10 mm Hg, a heart rate decrease greater than 10 beats per minute, an increase in urinary output by more than 10 mL/h, an increase in central venous oxygen saturation greater than 4%, or a lactate decrease greater than 1 mmol/L. Conclusions: Despite wide variability between individuals and countries, clear majority views emerged to describe practice, define FBT, and identify a response to it. Further investigation is now required to describe actual FBT practice and to identify the magnitude and duration of the physiological response to FBT and its relationship to patient-centered outcomes. (C) 2016 Elsevier Inc. All rights reserved.Peer reviewe

    Recent progress in low-carbon binders

    Get PDF
    The development of low-carbon binders has been recognized as a means of reducing the carbon footprint of the Portland cement industry, in response to growing global concerns over CO2 emissions from the construction sector. This paper reviews recent progress in the three most attractive low-carbon binders: alkali-activated, carbonate, and belite-ye'elimite-based binders. Alkali-activated binders/materials were reviewed at the past two ICCC congresses, so this paper focuses on some key developments of alkali-activated binders/materials since the last keynote paper was published in 2015. Recent progress on carbonate and belite-ye'elimite-based binders are also reviewed and discussed, as they are attracting more and more attention as essential alternative low-carbon cementitious materials. These classes of binders have a clear role to play in providing a sustainable future for global construction, as part of the available toolkit of cements

    Cooling system for the soft X-ray spectrometer onboard Astro-H

    Get PDF
    金沢大学理工研究域数物科学系The Soft X-ray Spectrometer (SXS) is a cryogenic high resolution X-ray spectrometer onboard the X-ray astronomy satellite Astro-H which will be launched in 2014. The detector array is cooled down to 50 mK using an adiabatic demagnetization refrigerator (ADR). The cooling chain from the room temperature to the ADR heat-sink is composed of superfluid liquid He, a Joule-Thomson cryocooler, and double-stage Stirling cryocoolers. It is designed to keep 30 l of liquid He for more than 5 years in the normal case, and longer than 3 years even if one of the cryocoolers fails. Cryogen-free operation is also possible in the normal case. It is fully redundant from the room temperature to the ADR heat-sink. © 2010 Elsevier Ltd
    corecore