487 research outputs found
Neutron Scattering and Its Application to Strongly Correlated Systems
Neutron scattering is a powerful probe of strongly correlated systems. It can
directly detect common phenomena such as magnetic order, and can be used to
determine the coupling between magnetic moments through measurements of the
spin-wave dispersions. In the absence of magnetic order, one can detect diffuse
scattering and dynamic correlations. Neutrons are also sensitive to the
arrangement of atoms in a solid (crystal structure) and lattice dynamics
(phonons). In this chapter, we provide an introduction to neutrons and neutron
sources. The neutron scattering cross section is described and formulas are
given for nuclear diffraction, phonon scattering, magnetic diffraction, and
magnon scattering. As an experimental example, we describe measurements of
antiferromagnetic order, spin dynamics, and their evolution in the
La(2-x)Ba(x)CuO(4) family of high-temperature superconductors.Comment: 31 pages, chapter for "Strongly Correlated Systems: Experimental
Techniques", edited by A. Avella and F. Mancin
Liquid-infiltrated photonic crystals - enhanced light-matter interactions for lab-on-a-chip applications
Optical techniques are finding widespread use in analytical chemistry for
chemical and bio-chemical analysis. During the past decade, there has been an
increasing emphasis on miniaturization of chemical analysis systems and
naturally this has stimulated a large effort in integrating microfluidics and
optics in lab-on-a-chip microsystems. This development is partly defining the
emerging field of optofluidics. Scaling analysis and experiments have
demonstrated the advantage of micro-scale devices over their macroscopic
counterparts for a number of chemical applications. However, from an optical
point of view, miniaturized devices suffer dramatically from the reduced
optical path compared to macroscale experiments, e.g. in a cuvette. Obviously,
the reduced optical path complicates the application of optical techniques in
lab-on-a-chip systems. In this paper we theoretically discuss how a strongly
dispersive photonic crystal environment may be used to enhance the light-matter
interactions, thus potentially compensating for the reduced optical path in
lab-on-a-chip systems. Combining electromagnetic perturbation theory with
full-wave electromagnetic simulations we address the prospects for achieving
slow-light enhancement of Beer-Lambert-Bouguer absorption, photonic band-gap
based refractometry, and high-Q cavity sensing.Comment: Invited paper accepted for the "Optofluidics" special issue to appear
in Microfluidics and Nanofluidics (ed. Prof. David Erickson). 11 pages
including 8 figure
Localization of gravity on a de Sitter thick braneworld without scalar fields
In this work we present a simple thick braneworld model that is generated by
an intriguing interplay between a 5D cosmological constant with a de Sitter
metric induced in the 3-brane without the inclusion of scalar fields. We show
that 4D gravity is localized on this brane, provide analytic expressions for
the massive Kaluza-Klein (KK) fluctuation modes and also show that the spectrum
of metric excitations displays a mass gap. We finally present the corrections
to Newton's law due to these massive modes. This model has no naked
singularities along the fifth dimension despite the existence of a mass gap in
the graviton spectrum as it happens in thick branes with 4D Poincare symmetry,
providing a simple model with very good features: the curvature is completely
smooth along the fifth dimension, it localizes 4D gravity and the spectrum of
gravity fluctuations presents a mass gap, a fact that rules out the existence
of phenomenologically dangerous ultralight KK excitations in the model. We
finally present our solution as a limit of scalar thick branes.Comment: 11 pages in latex, no figures, title and abstract changed, a new
section and some references adde
A modest start, but a steady rise in research use: a longitudinal study of nurses during the first five years in professional life
<p>Abstract</p> <p>Background</p> <p>Newly graduated nurses are faced with a challenging work environment that may impede their ability to provide evidence-based practice. However, little is known about the trajectory of registered nurses' use of research during the first years of professional life. Thus, the aim of the current study was to prospectively examine the extent of nurses' use of research during the first five years after undergraduate education and specifically assess changes over time.</p> <p>Method</p> <p>Survey data from a prospective cohort of 1,501 Swedish newly graduated nurses within the national LANE study (Longitudinal Analyses of Nursing Education and Entry in Worklife) were used to investigate perceived use of research over the first five years as a nurse. The dependent variables consisted of three single items assessing instrumental, conceptual, and persuasive research use, where the nurses rated their use on a five-point scale, from 'never' (1) to 'on almost every shift' (5). These data were collected annually and analyzed both descriptively and by longitudinal growth curve analysis.</p> <p>Results</p> <p>Instrumental use of research was most frequently reported, closely followed by conceptual use, with persuasive use occurring to a considerably lower extent. The development over time showed a substantial general upward trend, which was most apparent for conceptual use, increasing from a mean of 2.6 at year one to 3.6 at year five (unstandardized slope +0.25). However, the descriptive findings indicated that the increase started only after the second year. Instrumental use had a year one mean of 2.8 and a year five mean of 3.5 (unstandardized slope +0.19), and persuasive use showed a year one mean of 1.7 and a year five mean of 2.0 (unstandardized slope +0.09).</p> <p>Conclusion</p> <p>There was a clear trend of increasing research use by nurses during their first five years of practice. The level of the initial ratings also indicated the level of research use in subsequent years. However, it took more than two years of professional development before this increase 'kicked in.' These findings support previous research claiming that newly graduated nurses go through a 'transition shock,' reducing their ability to use research findings in clinical work.</p
Determinants of abstract acceptance for the Digestive Diseases Week – a cross sectional study
BACKGROUND: The Digestive Diseases Week (DDW) is the major meeting for presentation of research in gastroenterology. The acceptance of an abstract for presentation at this meeting is the most important determinant of subsequent full publication. We wished to examine the determinants of abstract acceptance for this meeting. METHODS: A cross-sectional study was performed, based on abstracts submitted to the DDW. All 17,205 abstracts submitted from 1992 to 1995 were reviewed for acceptance, country of origin and research type (controlled clinical trials (CCT), other clinical research (OCR), basic science (BSS)). A random sub-sample (n = 1,000) was further evaluated for formal abstract quality, statistical significance of study results and sample size. RESULTS: 326 CCT, 455 OCR and 219 BSS abstracts were evaluated in detail. Abstracts from N/W Europe (OR 0.4, 95% CI 0.3–0.6), S/E Europe (OR 0.4, 95% CI 0.2–0.6) and non-Western countries (OR 0.3, 95% CI 0.2–0.5) were less likely to be accepted than North-American contributions when controlling for research type. In addition, the OR for the acceptance for studies with negative results as compared to those with positive results was 0.4 (95% CI 0.3–0.7). A high abstract quality score was also weakly associated with acceptance rates (OR 1.4, 95% CI 1.0–2.0). CONCLUSIONS: North-American contributions and reports with statistically positive results have higher acceptance rates at the AGA. Formal abstract quality was also predictive for acceptance
An injury audit in high-level male youth soccer players from English, Spanish, Uruguayan and Brazilian academies.
OBJECTIVES: To identify the most common injury types/locations in high-level male youth soccer players (YSP). DESIGN: Prospective cohort surveillance study. SETTING: Professional soccer club academies. PARTICIPANTS: Six hundred and twenty-four high-level male YSP [Under 9 (U9) to U23 year-old age groups] from academies in England, Spain, Uruguay and Brazil. MAIN OUTCOME MEASURES: Injury type, location and severity were recorded during one season. Injury severity was compared between age groups, while injury type and location were compared between nations. RESULTS: Four hundred and forty-three training or match injuries were recorded, giving an injury rate of 0.71 per player. Non-contact injuries were most common (58.5%), with most (44.2%) resolved between 8 and 28 days. Most injuries (75.4%) occurred in the lower limbs, with muscle (29.6%) the most commonly injured tissue. U14 and U16 suffered a greater number of severe injuries relative to U12 and U19/U20/U23/Reserves. Tendon injury rate was higher in Brazil vs. Spain (p < 0.05), with low back/sacrum/pelvis injury rate highest in Spain (p < 0.05). CONCLUSIONS: The proportion of severe injuries in U14 and U16 suggests YSP injury risk is maturation-dependent. Minimal differences in type and location between high-level YSP from four different countries suggest injury rates in this population are geographically similar
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
X-ray emission from the Sombrero galaxy: discrete sources
We present a study of discrete X-ray sources in and around the
bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival
Chandra observations with a total exposure of ~200 ks. With a detection limit
of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30
kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler
et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS
observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray
binaries (LMXBs). We quantify the differential luminosity functions (LFs) for
both the detected GC and field LMXBs, whose power-low indices (~1.1 for the
GC-LF and ~1.6 for field-LF) are consistent with previous studies for
elliptical galaxies. With precise sky positions of the GCs without a detected
X-ray source, we further quantify, through a fluctuation analysis, the GC LF at
fainter luminosities down to 1E35 erg/s. The derived index rules out a
faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent
findings in several elliptical galaxies and the bulge of M31. On the other
hand, the 2-6 keV unresolved emission places a tight constraint on the field
LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101
sources in the halo of Sombrero. The presence of these sources cannot be
interpreted as galactic LMXBs whose spatial distribution empirically follows
the starlight. Their number is also higher than the expected number of cosmic
AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray
surveys. We suggest that either the cosmic X-ray background is unusually high
in the direction of Sombrero, or a distinct population of X-ray sources is
present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
- …