381 research outputs found

    The consistency of care for older patients with a hip fracture:are the results of the integrated orthogeriatric treatment model of the Centre of Geriatric Traumatology consistent 10 years after implementation?

    Get PDF
    Summary: In the past 10 years after implementation, the orthogeriatric treatment model led in general to consistent outcomes for 1555 older adults in terms of most of the complications and mortality. Surgery was more often delayed to 24–48 h after arrival at the hospital, while the length of hospital stay shortened. Introduction: Since 1 April 2008, patients aged ≥ 70 years presenting themselves with a hip fracture at Ziekenhuisgroep Twente (ZGT) have been treated according to the orthogeriatric treatment model. The aim of this study was to investigate if outcomes of the orthogeriatric treatment model are consistent over the first 10 years after implementation. Methods: Between 1 April 2008 and 31 December 2016, patients aged ≥ 70 years who were surgically treated at ZGT for a hip fracture were included and divided into three periods equally distributed in time. Patient characteristics, in-hospital logistics, complications, and mortality data were compared between the three periods. Results: A total of 1555 patients were included. There was a shift in the surgical treatment for the fractured neck of femur from dynamic hip screw/cannulated screws to hemiarthroplasty (p < 0.001). Surgery within 24 h after arrival to the hospital decreased (p < 0.001), while surgery within 48 h stayed the same (p = 0.085). Length of hospital stay significantly decreased over time (p < 0.001). Complication rates were consistent except for the number of postoperative anemia, delirium, and urinary tract infections. Mortality rates did not change over the years. Conclusions: The orthogeriatric treatment model leads in general to consistent outcomes concerning mortality and most of the complications, except for postoperative anemia, delirium, and urinary tract infections. Inconsistent complication rates were influenced by altered diagnosis and treatment protocols. Length of hospital stay reduced, while time to surgery was more often delayed to 24–48 h. Monitoring clinical outcomes of the orthogeriatric treatment model over time is recommended in order to optimize and maintain the quality of care for this frail patient population

    Quality indicators for hip fracture care, a systematic review

    Get PDF
    Quality indicators are used to measure quality of care and enable benchmarking. An overview of all existing hip fracture quality indicators is lacking. The primary aim was to identify quality indicators for hip fracture care reported in literature, hip fracture audits, and guidelines. The secondary aim was to compose a set of methodologically sound quality indicators for the evaluation of hip fracture care in clinical practice. A literature search according to the PRISMA guidelines and an internet search were performed to identify hip fracture quality indicators. The indicators were subdivided into process, structure, and outcome indicators. The methodological quality of the indicators was judged using the Appraisal of Indicators through Research and Evaluation (AIRE) instrument. For structure and process indicators, the construct validity was assessed. Sixteen publications, nine audits and five guidelines were included. In total, 97 unique quality indicators were found: 9 structure, 63 process, and 25 outcome indicators. Since detailed methodological information about the indicators was lacking, the AIRE instrument could not be applied. Seven indicators correlated with an outcome measure. A set of nine quality indicators was extracted from the literature, audits, and guidelines. Many quality indicators are described and used. Not all of them correlate with outcomes of care and have been assessed methodologically. As methodological evidence is lacking, we recommend the extracted set of nine indicators to be used as the starting point for further clinical research. Future research should focus on assessing the clinimetric properties of the existing quality indicators.Trauma Surger

    Textbook process as a composite quality indicator for in-hospital hip fracture care

    Get PDF
    A Summary Individual process indicators often do not enable the benchmarking of hospitals and often lack an association with outcomes of care. The composite hip fracture process indicator, textbook process, might be a tool to detect hospital variation and is associated with better outcomes during hospital stay.Purpose The aim of this study was to determine hospital variation in quality of hip fracture care using a composite process indicator (textbook process) and to evaluate at patient level whether fulfilment of the textbook process indicator was associated with better outcomes during hospital stay.Methods Hip fracture patients aged 70 and older operated in five hospitals between 1 January 2018 and 31 December 2018 were included. Textbook process for hip fracture care was defined as follows: (1) assessment of malnutrition (2) surgery within 24 h, (3) orthogeriatric management during admission and (4) operation by an orthopaedic trauma certified surgeon. Hospital variation analysis was done by computing an observed/expected ratio (O/E ratio) for textbook process at hospital level. The expected ratios were derived from a multivariable logistic regression analysis including all relevant case-mix variables. The association between textbook process compliance and in-hospital complications and prolonged hospital stay was determined at patient level in a multivariable logistic regression model, with correction for patient, treatment and hospital characteristics. In-hospital complications were anaemia, delirium, pneumonia, urinary tract infection, in-hospital fall, heart failure, renal insufficiency, pulmonary embolism, wound infection and pressure ulcer.Results Of the 1371 included patients, 753 (55%) received care according to textbook process. At hospital level, the textbook compliance rates ranged from 38 to 76%. At patient level, textbook process compliance was significantly associated with fewer complications (38% versus 46%) (OR 0.66, 95% CI 0.52-0.84), but not with hospital stay (median length of hospital stay was 5 days in both groups) (OR 1.01, 95% CI 0.78-1.30).Conclusion The textbook process indicator for hip fracture care might be a tool to detect hospital variation. At patient level, this quality indicator is associated with fewer complications during hospital stay.Trauma Surger

    Clockwise Torque of Sliding Hip Screws: Is There a Right Side?

    Get PDF
    OBJECTIVES: This study evaluated whether patients with a left-sided femoral neck fracture (FNF) treated with a sliding hip screw (SHS) had a higher implant failure rate than patients treated for a right-sided FNF. This was performed to determine the clinical relevance of the clockwise rotational torque of the femoral neck lag screw in a SHS, in relation to the rotational stability of left and right-sided FNFs after fixation. METHODS: Data were derived from the FAITH trial and Dutch Hip Fracture Audit (DHFA). Patients with a FNF, aged ≥50, treated with a SHS, with at least 3-month follow-up data available, were included. Implant failure was analyzed in a multivariable logistic regression model adjusted for age, sex, fracture displacement, prefracture living setting and functional mobility, and American Society for Anesthesiologists Class. RESULTS: One thousand seven hundred fifty patients were included, of which 944 (53.9%) had a left-sided and 806 (46.1%) a right-sided FNF. Implant failure occurred in 60 cases (3.4%), of which 31 were left-sided and 29 right-sided. No association between fracture side and implant failure was found [odds ratio (OR) for left vs. right 0.89, 95% confidence interval (CI) 0.52-1.52]. Female sex (OR 3.02, CI: 1.62-6.10), using a mobility aid (OR 2.02, CI 1.01-3.96) and a displaced fracture (OR 2.51, CI: 1.44-4.42), were associated with implant failure. CONCLUSIONS: This study could not substantiate the hypothesis that the biomechanics of the clockwise screw rotation of the SHS contributes to an increased risk of implant failure in left-sided FNFs compared with right-sided fractures. LEVEL OF EVIDENCE: Therapeutic Level II.See Instructions for Authors for a complete description of levels of evidence

    Validation of the Fracture Mobility Score against the Parker Mobility Score in hip fracture patients

    Get PDF
    IntroductionThe Parker Mobility Score has proven to be a valid and reliable measurement of hip fracture patient mobility. For hip fracture registries the Fracture Mobility Score is advised and used, although this score has never been validated. This study aims to validate the Fracture Mobility Score against the Parker Mobility Score. MethodsThe Dutch Hip Fracture Audit uses the Fracture Mobility Score (categorical scale). For the purpose of this study, five hospitals registered both the Fracture Mobility Score and the Parker Mobility Score (0 – 9 scale) for every admitted hip fracture patient in 2018. The Spearman correlation between the two scores was calculated. To test whether the correlation coefficient remained stable among different patient subgroups, analyses were stratified according to baseline patient characteristics. ResultsIn total 1,201 hip fracture patients were included. The Spearman correlation between the Fracture Mobility Score and the Parker Mobility Score was strong: 0.73 (p = Conclusion The Fracture Mobility Score is overall strongly correlated with the Parker Mobility Score and can be considered as a valid score to measure hip fracture patient mobility. This may encourage other hip fracture audits to also use the Fracture Mobility Score, which would increase the uniformity of mobility score results among national hip fracture audits and decrease the overall registration load. Trauma Surger

    Search for a W' boson decaying to a bottom quark and a top quark in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    Results are presented from a search for a W' boson using a dataset corresponding to 5.0 inverse femtobarns of integrated luminosity collected during 2011 by the CMS experiment at the LHC in pp collisions at sqrt(s)=7 TeV. The W' boson is modeled as a heavy W boson, but different scenarios for the couplings to fermions are considered, involving both left-handed and right-handed chiral projections of the fermions, as well as an arbitrary mixture of the two. The search is performed in the decay channel W' to t b, leading to a final state signature with a single lepton (e, mu), missing transverse energy, and jets, at least one of which is tagged as a b-jet. A W' boson that couples to fermions with the same coupling constant as the W, but to the right-handed rather than left-handed chiral projections, is excluded for masses below 1.85 TeV at the 95% confidence level. For the first time using LHC data, constraints on the W' gauge coupling for a set of left- and right-handed coupling combinations have been placed. These results represent a significant improvement over previously published limits.Comment: Submitted to Physics Letters B. Replaced with version publishe

    Search for the standard model Higgs boson decaying into two photons in pp collisions at sqrt(s)=7 TeV

    Get PDF
    A search for a Higgs boson decaying into two photons is described. The analysis is performed using a dataset recorded by the CMS experiment at the LHC from pp collisions at a centre-of-mass energy of 7 TeV, which corresponds to an integrated luminosity of 4.8 inverse femtobarns. Limits are set on the cross section of the standard model Higgs boson decaying to two photons. The expected exclusion limit at 95% confidence level is between 1.4 and 2.4 times the standard model cross section in the mass range between 110 and 150 GeV. The analysis of the data excludes, at 95% confidence level, the standard model Higgs boson decaying into two photons in the mass range 128 to 132 GeV. The largest excess of events above the expected standard model background is observed for a Higgs boson mass hypothesis of 124 GeV with a local significance of 3.1 sigma. The global significance of observing an excess with a local significance greater than 3.1 sigma anywhere in the search range 110-150 GeV is estimated to be 1.8 sigma. More data are required to ascertain the origin of this excess.Comment: Submitted to Physics Letters

    Measurement of the Lambda(b) cross section and the anti-Lambda(b) to Lambda(b) ratio with Lambda(b) to J/Psi Lambda decays in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    The Lambda(b) differential production cross section and the cross section ratio anti-Lambda(b)/Lambda(b) are measured as functions of transverse momentum pt(Lambda(b)) and rapidity abs(y(Lambda(b))) in pp collisions at sqrt(s) = 7 TeV using data collected by the CMS experiment at the LHC. The measurements are based on Lambda(b) decays reconstructed in the exclusive final state J/Psi Lambda, with the subsequent decays J/Psi to an opposite-sign muon pair and Lambda to proton pion, using a data sample corresponding to an integrated luminosity of 1.9 inverse femtobarns. The product of the cross section times the branching ratio for Lambda(b) to J/Psi Lambda versus pt(Lambda(b)) falls faster than that of b mesons. The measured value of the cross section times the branching ratio for pt(Lambda(b)) > 10 GeV and abs(y(Lambda(b))) < 2.0 is 1.06 +/- 0.06 +/- 0.12 nb, and the integrated cross section ratio for anti-Lambda(b)/Lambda(b) is 1.02 +/- 0.07 +/- 0.09, where the uncertainties are statistical and systematic, respectively.Comment: Submitted to Physics Letters

    Search for new physics in events with opposite-sign leptons, jets, and missing transverse energy in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search is presented for physics beyond the standard model (BSM) in final states with a pair of opposite-sign isolated leptons accompanied by jets and missing transverse energy. The search uses LHC data recorded at a center-of-mass energy sqrt(s) = 7 TeV with the CMS detector, corresponding to an integrated luminosity of approximately 5 inverse femtobarns. Two complementary search strategies are employed. The first probes models with a specific dilepton production mechanism that leads to a characteristic kinematic edge in the dilepton mass distribution. The second strategy probes models of dilepton production with heavy, colored objects that decay to final states including invisible particles, leading to very large hadronic activity and missing transverse energy. No evidence for an event yield in excess of the standard model expectations is found. Upper limits on the BSM contributions to the signal regions are deduced from the results, which are used to exclude a region of the parameter space of the constrained minimal supersymmetric extension of the standard model. Additional information related to detector efficiencies and response is provided to allow testing specific models of BSM physics not considered in this paper.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore