687 research outputs found

    Russel-Silver syndrome

    Get PDF
    Russel-Silver syndrome is a pattern of malformations whose most characteristic features are intrauterine and postnatal growth retardation, a characteristic facial appearance and limb asymmetry. We report a 9-month-old male born at 37 weeks' gestation. Family history, pregnancy and delivery revealed no significant anomalies. The infant had no intrauterine growth retardation (birth weight and height ranging between the 25 th and 50 th percentile). The infant's head circumference was disproportionately large for the small facial mass. Clinical findings included a small triangular face with frontal bossing, blue sclerae, thin lips with down-turned corners, retromicrognathia, clinodactyly of the fifth finger in both hands and limb asymmetry with undergrowth of the right leg and the left arm. The patient presented postnatal growth deficiency with weight and height 5th percentile; his head circumference grew normally along the 90 th percentile. Psychomotor development was appropriate for his age (9 months) according to the Sheridan Scale. On the basis of this clinical evidence we diagnosed Russel-Silver syndrome, attributing particular relevance to the normal intrauterine growth and the crossed asymmetry of the limbs

    Oral health-related quality of life of paediatric patients with AIDS

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Children with Acquired Immune Deficiency Syndrome (AIDS) exhibit impaired dental status, which can affect their quality of life. This study assessed the oral health-related quality of life of these patients and associated factors.</p> <p>Methods</p> <p>The "Child Perceptions Questionnaire 11-14", rating overall and domain-specific (oral symptoms, functional limitations, emotional well being, and social well being) oral health-related quality of life (OHR-QoL) was completed by 88 children with AIDS assisted in the Child Institute, Sao Paulo, Brazil. Parents or guardians provided behavioural and socio-demographic information. The clinical status was provided by hospital records. OHR-QoL covariates were assessed by Poisson regression analysis.</p> <p>Results</p> <p>The most affected OHR-QoL subscale concerned oral symptoms, whose rate was 23.9%. The direct answer for oral health and well being made up a rate of 47.7%. Brushing the teeth less than two times a day and viral load exceeding 10,000 HIV-RNA copies per millilitre of plasma were directly associated (p < 0.05) with a poorer oral health-related quality of life.</p> <p>Conclusions</p> <p>Children with more severe AIDS manifestations complained of poorer status of oral symptoms, functional limitations, emotional and social well being related to their oral health. Recognizing the factors that are associated with poorer OHR-QoL in children with AIDS may contribute to the planning of dental services for this population.</p

    Trends in socioeconomic inequalities in cancer mortality in Barcelona: 1992–2003

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The objective of this study was to assess trends in cancer mortality by educational level in Barcelona from 1992 to 2003.</p> <p>Methods</p> <p>The study population comprised Barcelona inhabitants aged 20 years or older. Data on cancer deaths were supplied by the system of information on mortality. Educational level was obtained from the municipal census. Age-standardized rates by educational level were calculated. We also fitted Poisson regression models to estimate the relative index of inequality (RII) and the Slope Index of Inequalities (SII). All were calculated for each sex and period (1992–1994, 1995–1997, 1998–2000, and 2001–2003).</p> <p>Results</p> <p>Cancer mortality was higher in men and women with lower educational level throughout the study period. Less-schooled men had higher mortality by stomach, mouth and pharynx, oesophagus, larynx and lung cancer. In women, there were educational inequalities for cervix uteri, liver and colon cancer. Inequalities of overall and specific types of cancer mortality remained stable in Barcelona; although a slight reduction was observed for some cancers.</p> <p>Conclusion</p> <p>This study has identified those cancer types presenting the greatest inequalities between men and women in recent years and shown that in Barcelona there is a stable trend in inequalities in the burden of cancer.</p

    The lancet weight determines wheal diameter in response to skin prick testing with histamine

    Get PDF
    BACKGROUND:Skin prick test (SPT) is a common test for diagnosing immunoglobulin E-mediated allergies. In clinical routine, technicalities, human errors or patient-related biases, occasionally results in suboptimal diagnosis of sensitization. OBJECTIVE:Although not previously assessed qualitatively, lancet weight is hypothesized to be important when performing SPT to minimize the frequency of false positives, false negatives, and unwanted discomfort. METHODS:Accurate weight-controlled SPT was performed on the volar forearms and backs of 20 healthy subjects. Four predetermined lancet weights were applied (25 g, 85 g, 135 g and 265 g) using two positive control histamine solutions (1 mg/mL and 10 mg/mL) and one negative control (saline). A total of 400 SPTs were conducted. The outcome parameters were: wheal size, neurogenic inflammation (measured by superficial blood perfusion), frequency of bleeding, and the lancet provoked pain response. RESULTS:The mean wheal diameter increased significantly as higher weights were applied to the SPT lancet, e.g. from 3.2 Âą 0.28 mm at 25 g to 5.4 Âą 1.7 mm at 265 g (p<0.01). Similarly, the frequency of bleeding, the provoked pain, and the neurogenic inflammatory response increased significantly. At 265 g saline evoked two wheal responses (/160 pricks) below 3 mm. CONCLUSION AND CLINICAL RELEVANCE:The applied weight of the lancet during the SPT-procedure is an important factor. Higher lancet weights precipitate significantly larger wheal reactions with potential diagnostic implications. This warrants additional research of the optimal lancet weight in relation to SPT-guidelines to improve the specificity and sensitivity of the procedure

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore