803 research outputs found

    Complete Set of Polarization Transfer Observables for the 12C(p,n)^{12}{\rm C}(p,n) Reaction at 296 MeV and 0∘^{\circ}

    Full text link
    A complete set of polarization transfer observables has been measured for the 12C(p,n)^{12}{\rm C}(p,n) reaction at Tp=296MeVT_p=296 {\rm MeV} and ξlab=0∘\theta_{\rm lab}=0^{\circ}. The total spin transfer Σ(0∘)\Sigma(0^{\circ}) and the observable f1f_1 deduced from the measured polarization transfer observables indicate that the spin--dipole resonance at Ex≃7MeVE_x \simeq 7 {\rm MeV} has greater 2−2^- strength than 1−1^- strength, which is consistent with recent experimental and theoretical studies. The results also indicate a predominance of the spin-flip and unnatural-parity transition strength in the continuum. The exchange tensor interaction at a large momentum transfer of Q≃3.6fm−1Q \simeq 3.6 {\rm fm}^{-1} is discussed.Comment: 4 pages, 4 figure

    Tools for BIM-GIS integration (IFC georeferencing and conversions): Results from the GeoBIM benchmark 2019

    Get PDF
    The integration of 3D city models with Building Information Models (BIM), coined as GeoBIM, facilitates improved data support to several applications, e.g., 3D map updates, building permits issuing, detailed city analysis, infrastructure design, context-based building design, to name a few. To solve the integration, several issues need to be tackled and solved, i.e., harmonization of features, interoperability, format conversions, integration of procedures. The GeoBIM benchmark 2019, funded by ISPRS and EuroSDR, evaluated the state of implementation of tools addressing some of those issues. In particular, in the part of the benchmark described in this paper, the application of georeferencing to Industry Foundation Classes (IFC) models and making consistent conversions between 3D city models and BIM are investigated, considering the OGC CityGML and buildingSMART IFC as reference standards. In the benchmark, sample datasets in the two reference standards were provided. External volunteers were asked to describe and test georeferencing procedures for IFC models and conversion tools between CityGML and IFC. From the analysis of the delivered answers and processed datasets, it was possible to notice that while there are tools and procedures available to support georeferencing and data conversion, comprehensive definition of the requirements, clear rules to perform such two tasks, as well as solid technological solutions implementing them, are still lacking in functionalities. Those specific issues can be a sensible starting point for planning the next GeoBIM integration agendas

    The field high-amplitude SX Phe variable BL Cam: results from a multisite photometric campaign. II. Evidence of a binary - possibly triple - system

    Full text link
    Short-period high-amplitude pulsating stars of Population I (ÎŽ\delta Sct stars) and II (SX Phe variables) exist in the lower part of the classical (Cepheid) instability strip. Most of them have very simple pulsational behaviours, only one or two radial modes being excited. Nevertheless, BL Cam is a unique object among them, being an extreme metal-deficient field high-amplitude SX Phe variable with a large number of frequencies. Based on a frequency analysis, a pulsational interpretation was previously given. aims heading (mandatory) We attempt to interpret the long-term behaviour of the residuals that were not taken into account in the previous Observed-Calculated (O-C) short-term analyses. methods heading (mandatory) An investigation of the O-C times has been carried out, using a data set based on the previous published times of light maxima, largely enriched by those obtained during an intensive multisite photometric campaign of BL Cam lasting several months. results heading (mandatory) In addition to a positive (161 ±\pm 3) x 10−9^{-9} yr−1^{-1} secular relative increase in the main pulsation period of BL Cam, we detected in the O-C data short- (144.2 d) and long-term (∌\sim 3400 d) variations, both incompatible with a scenario of stellar evolution. conclusions heading (mandatory) Interpreted as a light travel-time effect, the short-term O-C variation is indicative of a massive stellar component (0.46 to 1 M_{\sun}) with a short period orbit (144.2 d), within a distance of 0.7 AU from the primary. More observations are needed to confirm the long-term O-C variations: if they were also to be caused by a light travel-time effect, they could be interpreted in terms of a third component, in this case probably a brown dwarf star (≄\geq 0.03 \ M_{\sun}), orbiting in ∌\sim 3400 d at a distance of 4.5 AU from the primary.Comment: 7 pages, 5 figures, accepted for publication in A&

    Accuracy of self-reported height measurements in parents and its effect on mid-parental target height calculation

    Get PDF
    BACKGROUND: Clinical determination of mid-parental height is an important part of the assessment of a child's growth, however our clinical impression has been that parents cannot be relied upon to accurately report their own heights. Therefore, we conducted this study to assess the accuracy of parental height self-reporting and its effect on calculated mid-parental target height for children presenting to a pediatric endocrinology office. METHODS: All parents bringing their children for an initial evaluation to a pediatric endocrinology clinic over a period of nine months were questioned and then measured by a pediatric endocrinologist. Parents were blinded to the study. Mid-parental target heights, based on reported and actual height were compared. RESULTS: There were 241 families: 98 fathers and 217 mothers in our study. Mean measured paternal height was 173.2 cm, self reported 174.9 cm (p < 0.0001), partner reported 177 cm (p = 0.0004). Only 50% of fathers and 58% of mothers reported their height within ± 2 cm of their measured height, while 15% of fathers and 12% of mothers were inaccurate by more than 4 cm. Mean measured maternal height was 160.6 cm, self-reported 161.1 cm (NS), partner reported 161.7 cm (NS). Inaccuracy of height self-report had a small but significant effect on the mean MPTH (0.4 cm, p = 0.045). Analysis showed that only 70% of MPTH calculated by reported heights fell within ± 2 cm of MPTH calculated using measured heights, 24% being in ± 2–4 cm range, and 6% were inaccurate by more than 4 cm. CONCLUSION: There is a significant difference in paternal measured versus reported heights with an overall trend for fathers to overestimate their own height. A large subset of parents makes a substantial error in their height self-report, which leads to erroneous MPTH. Inaccuracy is even greater when one parent reports the other parent's height. When a child's growth is in question, measured rather than reported parental heights should be obtained

    Clinical mastitis in cows treated with sometribove (recombinant bovine somatotropin) and its relationship to milk yield.

    Get PDF
    Effect of sometribove (methionyl bovine somatotropin) on mastitis in 15 full lactation trials (914 cows) in Europe and the US and 70 short-term studies (2697 cows) in eight countries was investigated. In full lactation studies, sometribove (500 mg/2 wk) was given for 252 d, commencing 60 d postpartum. Although herds varied considerably, incidence of clinical mastitis within a herd was similar for cows receiving control and sometribove treatments. Relative risk analyses indicated no treatment effect, and percentage of mastitis during treatment was similar for control and sometribove groups. A positive linear relationship existed between peak milk yield and mastitis incidence (percentage of cows contracting mastitis or cases per 100 cow days); sometribove treatment did not alter this relationship. Increases in mastitis related to milk yield increase from sometribove or related to genetic selection were similar. When expressed per unit of milk, mastitis incidence declined slightly as milk yield increased; this relationship was not altered by sometribove. No effect on clinical mastitis was observed in 70 commercial herds utilizing sometribove for 84 d. However, effects were significant for stage of lactation and milk yield. Overall, studies represented a wide range of research and commercial situations demonstrating that sometribove had no effect on incidence of clinical mastitis during the lactation of treatment. Furthermore, sometribove did not alter typical relationships between milk yield or herd factors and incidence of clinical mastitis

    The KELT Follow-Up Network And Transit False-Positive Catalog: Pre-Vetted False Positives For TESS

    Get PDF
    The Kilodegree Extremely Little Telescope (KELT) project has been conducting a photometric survey of transiting planets orbiting bright stars for over 10 years. The KELT images have a pixel scale of ~23\u27\u27 pixel⁻Âč—very similar to that of NASA\u27s Transiting Exoplanet Survey Satellite (TESS)—as well as a large point-spread function, and the KELT reduction pipeline uses a weighted photometric aperture with radius 3\u27. At this angular scale, multiple stars are typically blended in the photometric apertures. In order to identify false positives and confirm transiting exoplanets, we have assembled a follow-up network (KELT-FUN) to conduct imaging with spatial resolution, cadence, and photometric precision higher than the KELT telescopes, as well as spectroscopic observations of the candidate host stars. The KELT-FUN team has followed-up over 1600 planet candidates since 2011, resulting in more than 20 planet discoveries. Excluding ~450 false alarms of non-astrophysical origin (i.e., instrumental noise or systematics), we present an all-sky catalog of the 1128 bright stars (6 \u3c V \u3c 13) that show transit-like features in the KELT light curves, but which were subsequently determined to be astrophysical false positives (FPs) after photometric and/or spectroscopic follow-up observations. The KELT-FUN team continues to pursue KELT and other planet candidates and will eventually follow up certain classes of TESS candidates. The KELT FP catalog will help minimize the duplication of follow-up observations by current and future transit surveys such as TESS

    Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered

    Search for New Physics with Jets and Missing Transverse Momentum in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for new physics is presented based on an event signature of at least three jets accompanied by large missing transverse momentum, using a data sample corresponding to an integrated luminosity of 36 inverse picobarns collected in proton--proton collisions at sqrt(s)=7 TeV with the CMS detector at the LHC. No excess of events is observed above the expected standard model backgrounds, which are all estimated from the data. Exclusion limits are presented for the constrained minimal supersymmetric extension of the standard model. Cross section limits are also presented using simplified models with new particles decaying to an undetected particle and one or two jets

    Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up

    Get PDF
    Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated
    • 

    corecore