110 research outputs found

    Novel calibration method for optical coherence tomography instruments using multiple spectrometers

    Get PDF
    In this report, a novel calibration method is introduced, which can be used in camera-based optical coherence tomography (OCT) instruments employing several spectrometers. To ensure that all spectrometers are calibrated, i.e. they sense the same spectral range and the distribution of the optical frequencies across the pixels of the cameras is the same, a hybrid method was used involving (i) a hardware procedure for an initial estimation of the edges of the spectra and (ii) a numerical Monte-Carlo based technique. The utility of such a procedure is demonstrated in an OCT system using a balance-detection (BD) scheme. The OCT system employs a single transmission diffraction grating and is driven by a supercontinuum source operating in the visible spectral range. Spectral alignment is paramount in producing high-sensitivity images free of artefacts. To ensure correct calibration, and speed up the calibration procedure, the master-slave (MS) technique of generating axial reflectivity profiles is employed. Preliminary results show an improvement of the signal of ~ 3dB and a mitigation of the background noise of over 5 dB

    Shuni Virus as Cause of Neurologic Disease in Horses

    Get PDF
    To determine which agents cause neurologic disease in horses, we conducted reverse transcription PCR on isolates from of a horse with encephalitis and 111 other horses with acute disease. Shuni virus was found in 7 horses, 5 of which had neurologic signs. Testing for lesser known viruses should be considered for horses with unexplained illness

    Guidelines for reporting on animal fecal transplantation (GRAFT) studies: recommendations from a systematic review of murine transplantation protocols

    Get PDF
    Fecal microbiota transplant (FMT) is a powerful tool used to connect changes in gut microbial composition with a variety of disease states and pathologies. While FMT enables potential causal relationships to be identified, the experimental details reported in preclinical FMT protocols are highly inconsistent and/or incomplete. This limitation reflects a current lack of authoritative guidance on reporting standards that would facilitate replication efforts and ultimately reproducible science. We therefore systematically reviewed all FMT protocols used in mouse models with the goal of formulating recommendations on the reporting of preclinical FMT protocols. Search strategies were applied across three databases (PubMed, EMBASE, and Ovid Medline) until June 30, 2020. Data related to donor attributes, stool collection, processing/storage, recipient preparation, administration, and quality control were extracted. A total of 1753 papers were identified, with 241 identified for data extraction and analysis. Of the papers included, 92.5% reported a positive outcome with FMT intervention. However, the vast majority of studies failed to address core methodological aspects including the use of anaerobic conditions (91.7% of papers lacked information), storage (49.4%), homogenization (33.6%), concentration (31.5%), volume (19.9%) and administration route (5.3%). To address these reporting limitations, we developed theGuidelines for Reporting Animal Fecal Transplant (GRAFT) that guide reporting standards for preclinical FMT. The GRAFT recommendations will enable robust reporting of preclinical FMT design, and facilitate high-quality peer review, improving the rigor and translation of knowledge gained through preclinical FMT studies.Kate R. Secombe, Ghanyah H. Al-Qadami, Courtney B. Subramaniam, Joanne M. Bowen, Jacqui Scott, Ysabella Z.A. Van Sebille ... et a

    Horizontal Branch Stars: The Interplay between Observations and Theory, and Insights into the Formation of the Galaxy

    Full text link
    We review HB stars in a broad astrophysical context, including both variable and non-variable stars. A reassessment of the Oosterhoff dichotomy is presented, which provides unprecedented detail regarding its origin and systematics. We show that the Oosterhoff dichotomy and the distribution of globular clusters (GCs) in the HB morphology-metallicity plane both exclude, with high statistical significance, the possibility that the Galactic halo may have formed from the accretion of dwarf galaxies resembling present-day Milky Way satellites such as Fornax, Sagittarius, and the LMC. A rediscussion of the second-parameter problem is presented. A technique is proposed to estimate the HB types of extragalactic GCs on the basis of integrated far-UV photometry. The relationship between the absolute V magnitude of the HB at the RR Lyrae level and metallicity, as obtained on the basis of trigonometric parallax measurements for the star RR Lyrae, is also revisited, giving a distance modulus to the LMC of (m-M)_0 = 18.44+/-0.11. RR Lyrae period change rates are studied. Finally, the conductive opacities used in evolutionary calculations of low-mass stars are investigated. [ABRIDGED]Comment: 56 pages, 22 figures. Invited review, to appear in Astrophysics and Space Scienc

    Simulating rare events in dynamical processes

    Full text link
    Atypical, rare trajectories of dynamical systems are important: they are often the paths for chemical reactions, the haven of (relative) stability of planetary systems, the rogue waves that are detected in oil platforms, the structures that are responsible for intermittency in a turbulent liquid, the active regions that allow a supercooled liquid to flow... Simulating them in an efficient, accelerated way, is in fact quite simple. In this paper we review a computational technique to study such rare events in both stochastic and Hamiltonian systems. The method is based on the evolution of a family of copies of the system which are replicated or killed in such a way as to favor the realization of the atypical trajectories. We illustrate this with various examples

    Porous ferroelectrics for energy harvesting applications

    Get PDF
    This paper provides an overview of energy harvesting using ferroelectric materials, with a particular focus on the energy harvesting capabilities of porous ferroelectric ceramics for both piezo- and pyroelectric harvesting. The benefits of introducing porosity into ferro- electrics such as lead zirconate titanate (PZT) has been known for over 30 years, but the potential advantages for energy harvesting from both ambient vibrations and temperature fluctuations have not been studied in depth. The article briefly discusses piezoelectric and pyro- electric energy harvesting, before evaluating the potential benefits of porous materials for increasing energy harvesting figures of merits and electromechanical/electrothermal coupling factors. Established processing routes are evaluated in terms of the final porous structure and the resulting effects on the electrical, thermal and mechanical properties

    Measurements of differential production cross sections for a Z boson in association with jets in pp collisions at root s=8 TeV

    Get PDF
    Peer reviewe

    The Cholecystectomy As A Day Case (CAAD) Score: A Validated Score of Preoperative Predictors of Successful Day-Case Cholecystectomy Using the CholeS Data Set

    Get PDF
    Background Day-case surgery is associated with significant patient and cost benefits. However, only 43% of cholecystectomy patients are discharged home the same day. One hypothesis is day-case cholecystectomy rates, defined as patients discharged the same day as their operation, may be improved by better assessment of patients using standard preoperative variables. Methods Data were extracted from a prospectively collected data set of cholecystectomy patients from 166 UK and Irish hospitals (CholeS). Cholecystectomies performed as elective procedures were divided into main (75%) and validation (25%) data sets. Preoperative predictors were identified, and a risk score of failed day case was devised using multivariate logistic regression. Receiver operating curve analysis was used to validate the score in the validation data set. Results Of the 7426 elective cholecystectomies performed, 49% of these were discharged home the same day. Same-day discharge following cholecystectomy was less likely with older patients (OR 0.18, 95% CI 0.15–0.23), higher ASA scores (OR 0.19, 95% CI 0.15–0.23), complicated cholelithiasis (OR 0.38, 95% CI 0.31 to 0.48), male gender (OR 0.66, 95% CI 0.58–0.74), previous acute gallstone-related admissions (OR 0.54, 95% CI 0.48–0.60) and preoperative endoscopic intervention (OR 0.40, 95% CI 0.34–0.47). The CAAD score was developed using these variables. When applied to the validation subgroup, a CAAD score of ≤5 was associated with 80.8% successful day-case cholecystectomy compared with 19.2% associated with a CAAD score >5 (p < 0.001). Conclusions The CAAD score which utilises data readily available from clinic letters and electronic sources can predict same-day discharges following cholecystectomy
    corecore