632 research outputs found

    Prevalence and Predictors of Vitamin D Insufficiency in Children: A Great Britain Population Based Study

    Get PDF
    Objectives To evaluate the prevalence and predictors of vitamin D insufficiency (VDI) in children In Great Britain. Design A nationally representative cross-sectional study survey of children (1102) aged 4–18 years (999 white, 570 male) living in private households (January 1997–1998). Interventions provided information about dietary habits, physical activity, socio-demographics, and blood sample. Outcome measures were vitamin D insufficiency (<50 nmol/L). Results Vitamin D levels (mean = 62.1 nmol/L, 95%CI 60.4–63.7) were insufficient in 35%, and decreased with age in both sexes (p<0.001). Young People living between 53–59 degrees latitude had lower levels (compared with 50–53 degrees, p = 0.045). Dietary intake and gender had no effect on vitamin D status. A logistic regression model showed increased risk of VDI in the following: adolescents (14–18 years old), odds ratio (OR) = 3.6 (95%CI 1.8–7.2) compared with younger children (4–8 years); non white children (OR = 37 [95%CI 15–90]); blood levels taken December-May (OR = 6.5 [95%CI 4.3–10.1]); on income support (OR = 2.2 [95%CI 1.3–3.9]); not taking vitamin D supplementation (OR = 3.7 [95%CI 1.4–9.8]); being overweight (OR 1.6 [95%CI 1.0–2.5]); <1/2 hour outdoor exercise/day/week (OR = 1.5 [95%CI 1.0–2.3]); watched >2.5 hours of TV/day/week (OR = 1.6[95%CI 1.0–2.4]). Conclusion We confirm a previously under-recognised risk of VDI in adolescents. The marked higher risk for VDI in non-white children suggests they should be targeted in any preventative strategies. The association of higher risk of VDI among children who exercised less outdoors, watched more TV and were overweight highlights potentially modifiable risk factors. Clearer guidelines and an increased awareness especially in adolescents are needed, as there are no recommendations for vitamin D supplementation in older children

    The RUSH2A Study: Best-Corrected Visual Acuity, Full-Field Electroretinography Amplitudes, and Full-Field Stimulus Thresholds at Baseline

    Get PDF
    Purpose: The purpose of this study was to evaluate baseline best corrected visual acuity (BCVA), full-field electroretinography (ERG), full-field stimulus thresholds (FST), and their relationship with baseline demographic and clinical characteristics in the Rate of Progression in Usher syndrome type 2 (USH2A)-related Retinal Degeneration (RUSH2A) multicenter study. Methods: Participants had Usher syndrome type 2 (USH2, N = 80) or autosomal recessive nonsyndromic retinitis pigmentosa (ARRP, N = 47) associated with biallelic variants in the USH2A gene. Associations of demographic and clinical characteristics with BCVA, ERG, and FST were assessed with regression models. Results: In comparison to ARRP, USH2 had worse BCVA (median 79 vs. 82 letters; P < 0.001 adjusted for age), lower rod-mediated ERG b-wave amplitudes (median 0.0 vs. 6.6 µV; P < 0.001) and 30 Hz flicker cone-mediated ERG amplitudes (median 1.5 vs. 3.1 µV; P = 0.001), and higher (white, blue, and red) FST thresholds (means [-26, -31, -23 dB] vs. [-39, -45, -28 dB]; P < 0.001 for all stimuli). After adjusting for age, gender, and duration of vision loss, the difference in BCVA between diagnosis groups was attenuated (P = 0.09). Only diagnosis was associated with rod- and cone-mediated ERG parameters, whereas both genders (P = 0.04) and duration of visual loss (P < 0.001) also were associated with FST white stimulus. Conclusions: USH2 participants had worse BCVA, ERG, and FST than ARRP participants. FST was strongly associated with duration of disease; it remains to be determined whether it will be a sensitive measure of progression. Translational Relevance: Using standardized research protocols in RUSH2A, measures have been identified to monitor disease progression and treatment response and differentiate features of prognostic relevance between USH2 and ARRP participants with USH2A mutations

    Awareness of vitamin D deficiency among at-risk patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Vitamin D deficiency is a significant problem for a growing proportion of the UK population. Individuals with dark or covered skin are at particularly high risk due to ethno-cultural, environmental and genetic factors. We assessed the level of awareness of vitamin D deficiency among at-risk patients in order to identify groups most in need of education.</p> <p>Findings</p> <p>A cross-sectional survey using a piloted questionnaire was conducted among consecutive at-risk patients without a diagnosis of Vitamin D deficiency arriving at a large inner city general practice in the North West of England over a five day period. The survey was completed by 221 patients. The mean age was 35 years. 28% of them (n = 61) had never heard about vitamin D. Older patients (p = 0.003) were less likely to have heard about vitamin D. 54% of participants were unaware of the commonest symptoms of vitamin D deficiency. 34% did not expose their skin other than their face in the last one year, and 11% did not include vitamin D rich foods in their diet.</p> <p>Conclusion</p> <p>The majority of at-risk patients are aware of vitamin D; nevertheless, there is a significant lack of knowledge among older people, who have higher morbidity. A programme of targeted education of the at-risk population is recommended.</p

    Examining assumptions regarding valid electronic monitoring of medication therapy: development of a validation framework and its application on a European sample of kidney transplant patients

    Get PDF
    BACKGROUND: Electronic monitoring (EM) is used increasingly to measure medication non-adherence. Unbiased EM assessment requires fulfillment of assumptions. The purpose of this study was to determine assumptions needed for internal and external validity of EM measurement. To test internal validity, we examined if (1) EM equipment functioned correctly, (2) if all EM bottle openings corresponded to actual drug intake, and (3) if EM did not influence a patient's normal adherence behavior. To assess external validity, we examined if there were indications that using EM affected the sample representativeness. METHODS: We used data from the Supporting Medication Adherence in Renal Transplantation (SMART) study, which included 250 adult renal transplant patients whose adherence to immunosuppressive drugs was measured during 3 months with the Medication Event Monitoring System (MEMS). Internal validity was determined by assessing the prevalence of nonfunctioning EM systems, the prevalence of patient-reported discrepancies between cap openings and actual intakes (using contemporaneous notes and interview at the end of the study), and by exploring whether adherence was initially uncharacteristically high and decreased over time (an indication of a possible EM intervention effect). Sample representativeness was examined by screening for differences between participants and non-participants or drop outs on non-adherence. RESULTS: Our analysis revealed that some assumptions were not fulfilled: 1) one cap malfunctioned (0.4%), 2) self-reported mismatches between bottle openings and actual drug intake occurred in 62% of the patients (n = 155), and 3) adherence decreased over the first 5 weeks of the monitoring, indicating that EM had a waning intervention effect. CONCLUSION: The validity assumptions presented in this article should be checked in future studies using EM as a measure of medication non-adherence

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore