127 research outputs found
Recommended from our members
A multimodel assessment of future projections of North Atlantic and European extratropical cyclones in the CMIP5 climate models
The response of North Atlantic and European extratropical cyclones to climate change is investigated in the climate models participating in phase 5 of the Coupled Model Intercomparison Project (CMIP5). In contrast to previous multimodel studies, a feature-tracking algorithm is here applied to separately quantify the re- sponses in the number, the wind intensity, and the precipitation intensity of extratropical cyclones. Moreover, a statistical framework is employed to formally assess the uncertainties in the multimodel projections. Under the midrange representative concentration pathway (RCP4.5) emission scenario, the December–February (DJF) response is characterized by a tripolar pattern over Europe, with an increase in the number of cyclones in central Europe and a decreased number in the Norwegian and Mediterranean Seas. The June–August (JJA) response is characterized by a reduction in the number of North Atlantic cyclones along the southern flank of the storm track. The total number of cyclones decreases in both DJF (24%) and JJA (22%). Classifying cyclones according to their intensity indicates a slight basinwide reduction in the number of cy- clones associated with strong winds, but an increase in those associated with strong precipitation. However, in DJF, a slight increase in the number and intensity of cyclones associated with strong wind speeds is found over the United Kingdom and central Europe. The results are confirmed under the high-emission RCP8.5 scenario, where the signals tend to be larger. The sources of uncertainty in these projections are discussed
A novel mass spectrometry-based assay for GSK-3β activity
BACKGROUND: As a component of the progression from genomic to proteomic analysis, there is a need for accurate assessment of protein post-translational modifications such as phosphorylation. Traditional kinase assays rely heavily on the incorporation of γ-P(32 )radiolabeled isotopes, monoclonal anti-phospho-protein antibodies, or gel shift analysis of substrate proteins. In addition to the expensive and time consuming nature of these methods, the use of radio-ligands imposes restrictions based on the half-life of the radionucleotides and pose potential health risks to researchers. With the shortcomings of traditional assays in mind, the aim of this study was to develop a high throughput, non-radioactive kinase assay for screening Glycogen Synthase Kinase-3beta (GSK-3β) activity. RESULTS: Synthetic peptide substrates designed with a GSK-3β phosphorylation site were assayed with both recombinant enzyme and GSK-3β immunoprecipitated from NIH 3T3 fibroblasts. A molecular weight shift equal to that of a single phosphate group (80 Da.) was detected by surface enhanced laser desorption/ionization time of flight mass spectrometry (SELDI-TOF-MS) in a GSK-3β target peptide (2B-Sp). Not only was there a dose-dependent response in molecular weight shift to the amount of recombinant GSK-3β used in this assay, this shift was also inhibited by lithium chloride (LiCl), in a dose-dependent manner. CONCLUSION: We present here a novel method to sensitively measure peptide phosphorylation by GSK-3β that, due to the incorporation of substrate controls, is applicable to either purified enzyme or cell extracts. Future studies using this method have the potential to elucidate the activity of GSK-3β in vivo, and to screen enzyme activity in relation to a variety of GSK-3β related disorders
Helium exhaust experiments on JET with Type I ELMs in H-mode and with type III ELMs in ITB discharges
An analysis of helium exhaust experiments on JET in the MkII-GB divertor configuration is presented. Helium is pumped by applying an argon frost layer on the divertor cryo pump. Measurement of the helium retention time, tau(He)(*),, is performed in two ways: by the introduction of helium in gas puffs and measurement of the subsequent decay time constant of the helium content, tau(He)(d*); and by helium beam injection and measurement of the helium replacement time, tau(He)(r*). In ELMy H-mode, with plasma configuration optimized for pumping, tau(He)(d*) approximate to 7.2 x tau(E)(th) is achieved, where tau(E)(th) is the thermal energy replacement time. For quasi-steady internal transport barrier (ITB) discharges, the achieved tau(He)(r*) approximate to 4.1 x tau(E)(th) is significantly lower. The achieved helium recycling coefficient, confirmed by an independent measurement to be R-eff approximate to 0.91, is the same in both scenarios. None of the discharges are dominated by core confinement. The difference in tau(He)(*)/tau(E)(th) is instead due to the confinement properties of the edge plasma, which is characterized by Type I ELMs for the H-mode discharges studied, and Type III ELMs for the quasi-steady ITB discharges. This difference is quantified by an independent measurement of the ratio of the helium replacement time with a helium edge source to the energy confinement time
Affordable flow cytometry for enumeration of absolute CD4(+ )T-lymphocytes to identify subtype C HIV-1 infected adults requiring antiretroviral therapy (ART) and monitoring response to ART in a resource-limited setting
BACKGROUND: The World Health Organization (WHO)'s "3 × 5 program" has spurred efforts to place 3 million people on combination antiretroviral therapy (ART) for treatment of AIDS in resource-limited countries. Paradoxically, the cost of CD4(+ )T-lymphocyte count essential for decision-making to commence HIV positive adults on ART as well as for monitoring responses to ART remains unaffordable in most resource-limited countries. Thus, low-cost methods for enumerating CD4(+ )T-lymphocyte are urgently needed. OBJECTIVE: To evaluate Cyflow cytometry (Cyflow SL, Partec, Munster, Germany) for enumeration of absolute CD4(+ )T-lymphocyte in subtype C HIV-1 seropositive subjects using FACSCount (Becton and Dickinson, Immunocytometry Systems, San Jose, CA, USA) as the "predicate method". METHODS: A total of 150 HIV-1 seropositive subjects were included in the evaluation exercise. Fifty-eight specimens were collected from pregnant HIV-1 seropositive women (subtype C drug resistance study). Twenty-seven specimens were collected from women and their spouses with AIDS followed in a Duke ART study to assess the immunologic and virologic responses to generic ART, comprising Stavudine, Lamivudine and Nevirapine (Stalanev, Varichem Labs, Harare, Zimbabwe). Sixty-five specimens were collected from AIDS patients enrolled in an ongoing Kaposi Sarcoma (KS) study to investigate impact of ART on KS progression. Enumeration of CD4(+ )T-lymphocytes using FACSCount is routinely conducted for all the three studies. The Medical Research Council of Zimbabwe and Medicines Control Authority of Zimbabwe approved the studies. Whole blood was collected in EDTA vacutainer tubes and aliquoted into two tubes (200 μL in each). CD4(+ )T-lymphocyte counts were enumerated using a Cyflow counter, in the Department of Immunology and a FACSCount in the Department of Obstetrics and Gynaecology within 6 hours of phlebotomy following manufacturers' instructions. RESULTS: Using linear regression analysis, there was a very strong correlation (R = 0.991) between the overall CD4(+ )T-lymphocyte counts obtained by FACSCount and those obtained by Cyflow. When data analysis was stratified by study groups, there was a strong correlation between the FACSCount and Cyflow CD4(+ )T-lymphocyte counts from subjects in the three independent studies; Subtype C resistance (R(2 )= 0.987), Duke ART (R(2 )= 0.980) and KS (R(2 )= 0.994), Table 1. Using Bland-Altman plots, the overall, absolute CD4(+ )T lymphocytes obtained by the two methods were in excellent agreement (mean difference 1.21, 95% Confidence Interval {CI): -2.1 to 3.3). For the 0–250 CD4(+ )T-lymphocytes range, the CD4 counts obtained using FACSCount were also in good agreement with those obtained using Cyflow counter (mean difference = 2.6 cells/μL, 95% CI: -1.1 to 6.3). Similarly, in the 251–500 (mean difference 1.0, cells/μL, 95% CI: -3.7 to 5.6) and the 501–1200 (mean difference = 0.29 cells/μL, 95% CI: -8.1 to 8.7) CD4 T-lymphocytes range, good agreement was observed. CONCLUSION: The Cyflow counter is as accurate as the FACSCount in enumerating absolute CD4(+ )T-lymphocytes in the range 1–1200 cells/μL. Cyflow cytometry is relatively affordable, easy to use technology that is useful not only in identifying HIV seropositive individuals who require ART but also for monitoring immunologic responses to ART
The Knowledge Spillover Theory of Entrepreneurship and Foreign Direct Investment
We explore if the Knowledge Spillover Theory of Entrepreneurship, applied to FDI, provides at least a partial explanation for the greater emergence of recent knowledge-based entrepreneurship in Ireland compared with Wales. In order to examine how FDI and entrepreneurship policy in these two regions might have influenced the levels of knowledge-based entrepreneurship, we outline FDI and entrepreneurship policies for Wales and Ireland and key measures of knowledge creation, and evaluate the extent and nature of FDI activity and its relationship with entrepreneurship in general and knowledge-based entrepreneurship in particular. Implications include possible policy di-rections for countries that are characterized by weak knowledge-creating institutions yet wish to encourage knowledge-based entrepreneurship
Wnt expression is not correlated with β-catenin dysregulation in Dupuytren's Disease
BACKGROUND: Dupuytren's contracture or disease (DD) is a fibro-proliferative disease of the hand that results in finger flexion contractures. Increased cellular β-catenin levels have been identified as characteristic of this disease. As Wnts are the most widely recognized upstream regulators of cellular β-catenin accumulation, we have examined Wnt gene expression in surgical specimens and in DD-derived primary cell cultures grown in two-dimensional monolayer culture or in three-dimensional FPCL collagen lattice cultures. RESULTS: The Wnt expression profile of patient-matched DD and unaffected control palmar fascia tissue was determined by a variety of complimentary methods; Affymetrix Microarray analysis, specific Wnt and degenerative primer-based Reverse Transcriptase (RT)-PCR, and Real Time PCR. Microarray analysis identified 13 Wnts associated with DD and control tissues. Degenerate Wnt RT-PCR analysis identified Wnts 10b and 11, and to a lesser extent 5a and 9a, as the major Wnt family members expressed in our patient samples. Competitive RT-PCR analysis identified significant differences between the levels of expression of Wnts 9a, 10b and 11 in tissue samples and in primary cell cultures grown as monolayer or in FPCL, where the mRNA levels in tissue > FPCL cultures > monolayer cultures. Real Time PCR data confirmed the down-regulation of Wnt 11 mRNA in DD while Wnt 10b, the most frequently isolated Wnt in DD and control palmar fascia, displayed widely variable expression between the methods of analysis. CONCLUSION: These data indicate that changes in Wnt expression per se are unlikely to be the cause of the observed dysregulation of β-catenin expression in DD
Type-1 Collagen differentially alters β-catenin accumulation in primary Dupuytren's Disease cord and adjacent palmar fascia cells
<p>Abstract</p> <p>Background</p> <p>Dupuytren's Disease (DD) is a debilitating contractile fibrosis of the palmar fascia characterised by excess collagen deposition, contractile myofibroblast development, increased Transforming Growth Factor-β levels and β-catenin accumulation. The aim of this study was to determine if a collagen-enriched environment, similar to <it>in vivo </it>conditions, altered β-catenin accumulation by primary DD cells in the presence or absence of Transforming Growth Factor-β.</p> <p>Methods</p> <p>Primary DD and patient matched, phenotypically normal palmar fascia (PF) cells were cultured in the presence or absence of type-1 collagen and Transforming Growth Factor-β1. β-catenin and α-smooth muscle actin levels were assessed by western immunoblotting and immunofluorescence microscopy.</p> <p>Results</p> <p>DD cells display a rapid depletion of cellular β-catenin not evident in patient-matched PF cells. This effect was not evident in either cell type when cultured in the absence of type-1 collagen. Exogenous addition of Transforming Growth Factor-β1 to DD cells in collagen culture negates the loss of β-catenin accumulation. Transforming Growth Factor-β1-induced α-smooth muscle actin, a marker of myofibroblast differentiation, is attenuated by the inclusion of type-1 collagen in cultures of DD and PF cells.</p> <p>Conclusion</p> <p>Our findings implicate type-1 collagen as a previously unrecognized regulator of β-catenin accumulation and a modifier of TGF-β1 signaling specifically in primary DD cells. These data have implications for current treatment modalities as well as the design of <it>in vitro </it>models for research into the molecular mechanisms of DD.</p
Analysis of structural brain asymmetries in attention-deficit/hyperactivity disorder in 39 datasets
Objective
Some studies have suggested alterations of structural brain asymmetry in attention-deficit/hyperactivity disorder (ADHD), but findings have been contradictory and based on small samples. Here, we performed the largest ever analysis of brain left-right asymmetry in ADHD, using 39 datasets of the ENIGMA consortium.
Methods
We analyzed asymmetry of subcortical and cerebral cortical structures in up to 1,933 people with ADHD and 1,829 unaffected controls. Asymmetry Indexes (AIs) were calculated per participant for each bilaterally paired measure, and linear mixed effects modeling was applied separately in children, adolescents, adults, and the total sample, to test exhaustively for potential associations of ADHD with structural brain asymmetries.
Results
There was no evidence for altered caudate nucleus asymmetry in ADHD, in contrast to prior literature. In children, there was less rightward asymmetry of the total hemispheric surface area compared to controls (t = 2.1, p = .04). Lower rightward asymmetry of medial orbitofrontal cortex surface area in ADHD (t = 2.7, p = .01) was similar to a recent finding for autism spectrum disorder. There were also some differences in cortical thickness asymmetry across age groups. In adults with ADHD, globus pallidus asymmetry was altered compared to those without ADHD. However, all effects were small (Cohen’s d from −0.18 to 0.18) and would not survive study-wide correction for multiple testing.
Conclusion
Prior studies of altered structural brain asymmetry in ADHD were likely underpowered to detect the small effects reported here. Altered structural asymmetry is unlikely to provide a useful biomarker for ADHD, but may provide neurobiological insights into the trait.publishedVersio
Frequency drift in MR spectroscopy at 3T
Purpose: Heating of gradient coils and passive shim components is a common cause of instability in the B-0 field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites.Method: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors. Phantom water signals were acquired before and after an EPI sequence. The protocol consisted of: minimal preparatory imaging; a short pre-fMRI PRESS; a ten-minute fMRI acquisition; and a long post-fMRI PRESS acquisition. Both pre- and post-fMRI PRESS were non-water suppressed. Real-time frequency stabilization/adjustment was switched off when appropriate. Sixty scanners repeated the protocol for a second dataset. In addition, a three-hour post-fMRI MRS acquisition was performed at one site to observe change of gradient temperature and drift rate. Spectral analysis was performed using MATLAB. Frequency drift in pre-fMRI PRESS data were compared with the first 5:20 minutes and the full 30:00 minutes of data after fMRI. Median (interquartile range) drifts were measured and showed in violin plot. Paired t-tests were performed to compare frequency drift pre- and post-fMRI. A simulated in vivo spectrum was generated using FID-A to visualize the effect of the observed frequency drifts. The simulated spectrum was convolved with the frequency trace for the most extreme cases. Impacts of frequency drifts on NAA and GABA were also simulated as a function of linear drift. Data from the repeated protocol were compared with the corresponding first dataset using Pearson's and intraclass correlation coefficients (ICC).Results: Of the data collected from 99 scanners, 4 were excluded due to various reasons. Thus, data from 95 scanners were ultimately analyzed. For the first 5:20 min (64 transients), median (interquartile range) drift was 0.44 (1.29) Hz before fMRI and 0.83 (1.29) Hz after. This increased to 3.15 (4.02) Hz for the full 30 min (360 transients) run. Average drift rates were 0.29 Hz/min before fMRI and 0.43 Hz/min after. Paired t-tests indicated that drift increased after fMRI, as expected (p < 0.05). Simulated spectra convolved with the frequency drift showed that the intensity of the NAA singlet was reduced by up to 26%, 44 % and 18% for GE, Philips and Siemens scanners after fMRI, respectively. ICCs indicated good agreement between datasets acquired on separate days. The single site long acquisition showed drift rate was reduced to 0.03 Hz/min approximately three hours after fMRI.Discussion: This study analyzed frequency drift data from 95 3T MRI scanners. Median levels of drift were relatively low (5-min average under 1 Hz), but the most extreme cases suffered from higher levels of drift. The extent of drift varied across scanners which both linear and nonlinear drifts were observed.</p
- …
