155 research outputs found

    Convexal subarachnoid hemorrhage and acute ischemic stroke: a border zone matter?

    Get PDF
    Background Convexal subarachnoid hemorrhage (c-SAH) is an infrequent condition with variable causes. c-SAH concomitant to acute ischemic stroke (AIS) is even less frequent, and the relationship between the two conditions remains unclear. Methods Between January 2016 and January 2018, we treated four patients who were referred to our stroke unit with ischemic stroke and concomitant nontraumatic c-SAH. The patients underwent an extensive diagnostic workup, including digital subtraction angiography (DSA). Results All four patients developed acute focal neurological symptoms with restricted MRI diffusion in congruent areas. In three of the patients, infarcts were in a border zone between the main cerebral arteries and c-SAH was nearby. The fourth patient showed a small cortical infarct, and c-SAH was in a border zone territory of the contralateral hemisphere. An embolic source was discovered or strongly suspected in all cases. One patient was treated with intravenous thrombolysis, but this treatment was not related to c-SAH. None of the four patients showed microbleeds or further cortical siderosis, thus excluding cerebral amyloid angiopathy. In addition, DSA did not show signs of vasculitis, reversible cerebral vasoconstriction syndrome, or intracranial arterial dissection. Conclusions We proposed the embolism or hemodynamic changes of the border zone arterioles as a unifying pathogenetic hypothesis of coexisting c-SAH and AIS

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Complications of mechanical thrombectomy for acute ischemic stroke: Incidence, risk factors, and clinical relevance in the Italian Registry of Endovascular Treatment in acute stroke

    Get PDF
    BACKGROUND: There are limited data concerning procedure-related complications of endovascular thrombectomy for large vessel occlusion strokes. AIMS: We evaluated the cumulative incidence, the clinical relevance in terms of increased disability and mortality, and risk factors for complications. METHODS: From January 2011 to December 2017, 4799 patients were enrolled by 36 centers in the Italian Registry of Endovascular Stroke Treatment. Data on demographic and procedural characteristics, complications, and clinical outcome at three months were prospectively collected. RESULTS: The complications cumulative incidence was 201 per 1000 patients undergoing endovascular thrombectomy. Ongoing antiplatelet therapy (p < 0.01; OR 1.82, 95% CI: 1.21-2.73) and large vessel occlusion site (carotid-T, p < 0.03; OR 3.05, 95% CI: 1.13-8.19; M2-segment-MCA, p < 0.01; OR 4.54, 95% CI: 1.66-12.44) were associated with a higher risk of subarachnoid hemorrhage/arterial perforation. Thrombectomy alone (p < 0.01; OR 0.50, 95% CI: 0.31-0.83) and younger age (p < 0.04; OR 0.98, 95% CI: 0.97-0.99) revealed a lower risk of developing dissection. M2-segment-MCA occlusion (p < 0.01; OR 0.35, 95% CI: 0.19-0.64) and hypertension (p < 0.04; OR 0.77, 95% CI: 0.6-0.98) were less related to clot embolization. Higher NIHSS at onset (p < 0.01; OR 1.04, 95% CI: 1.02-1.06), longer groin-to-reperfusion time (p < 0.01; OR 1.05, 95% CI: 1.02-1.07), diabetes (p < 0.01; OR 1.67, 95% CI: 1.25-2.23), and LVO site (carotid-T, p < 0.01; OR 1.96, 95% CI: 1.26-3.05; M2-segment-MCA, p < 0.02; OR 1.62, 95% CI: 1.08-2.42) were associated with a higher risk of developing symptomatic intracerebral hemorrhage compared to no/asymptomatic intracerebral hemorrhage. The subgroup of patients treated with thrombectomy alone presented a lower risk of symptomatic intracerebral hemorrhage (p < 0.01; OR 0.70; 95% CI: 0.55-0.90). Subarachnoid hemorrhage/arterial perforation and symptomatic intracerebral hemorrhage after endovascular thrombectomy worsen both functional independence and mortality at three-month follow-up (p < 0.01). Distal embolization is associated with neurological deterioration (p < 0.01), while arterial dissection did not affect clinical outcome at follow-up. CONCLUSIONS: Complications globally considered are not uncommon and may result in poor clinical outcome. Early recognition of risk factors might help to prevent complications and manage them appropriately in order to maximize endovascular thrombectomy benefits

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance

    Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPDuring autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    • …
    corecore