    A miniaturized endocardial electromagnetic energy harvester for leadless cardiac pacemakers

    Get PDF
    Life expectancy of contemporary cardiac pacemakers is limited due to the use of an internal primary battery. Repeated device replacement interventions are necessary, which leads to an elevated risk for patients and an increase of health care costs. The aim of our study is to investigate the feasibility of powering an endocardial pacemaker by converting a minimal amount of the heart's kinetic energy into electric energy. The intrinsic cardiac muscle activity makes it an ideal candidate as continuous source of energy for endocardial pacemakers. For this reason, we developed a prototype able to generate enough power to supply a pacing circuit at different heart rates. The prototype consists of a mass imbalance that drives an electromagnetic generator while oscillating. We developed a mathematical model to estimate the amount of energy harvested from the right ventricle. Finally, the implemented prototype was successfully tested during in-vitro and in-vivo experiments

    Preliminary Study of Prospective ECG-Gated 320-Detector CT Coronary Angiography in Patients with Ventricular Premature Beats

    Get PDF
    BACKGROUND: To study the applicability of prospective ECG-gated 320-detector CT coronary angiography (CTCA) in patients with ventricular premature beats (VPB), and determine the scanning mode that best maximizes image quality and reduces radiation dose. METHODS: 110 patients were divided into a VPB group (60 cases) and a control group (50 cases) using CTCA. All the patients then underwent coronary angiography (CAG) within one month. CAG served as a reference standard through which the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CTCA in diagnosing significant coronary artery stenosis (luminal stenosis ≥50%) could be analyzed. The two radiologists with more than 3 years' experience in cardiac CT each finished the image analysis after consultation. A personalized scanning mode was adopted to compare image quality and radiation dose between the two groups. METHODOLOGY/PRINCIPAL FINDINGS: At the coronary artery segment level, sensitivity, specificity, PPV, and NPV in the premature beat group were 92.55%, 98.21%, 88.51%, and 98.72% respectively. In the control group these values were found to be 95.79%, 98.42%, 90.11%, and 99.28% respectively. Between the two groups, specificity, sensitivity PPV, NPV was no significant difference. The two groups had no significant difference in image quality score (P>0.05). Heart rate (77.20±12.07 bpm) and radiation dose (14.62±1.37 mSv) in the premature beat group were higher than heart rate (58.72±4.73 bpm) and radiation dose (3.08±2.35 mSv) in the control group. In theVPB group, the radiation dose (34.55±7.12 mSv) for S-field scanning was significantly higher than the radiation dose (15.10±1.12 mSv) for M-field scanning. CONCLUSIONS/SIGNIFICANCE: With prospective ECG-gated scanning for VPB, the diagnostic accuracy of coronary artery stenosis is very high. Scanning field adjustment can reduce radiation dose while maintaining good image quality. For patients with slow heart rates and good rhythm, there was no statistically significant difference in image quality

    Potential value of automated daily screening of cardiac resynchronization therapy defibrillator diagnostics for prediction of major cardiovascular events: results from Home-CARE (Home Monitoring in Cardiac Resynchronization Therapy) study

    Get PDF
    Aim To investigate whether diagnostic data from implanted cardiac resynchronization therapy defibrillators (CRT-Ds) retrieved automatically at 24 h intervals via a Home Monitoring function can enable dynamic prediction of cardiovascular hospitalization and death. Methods and results Three hundred and seventy-seven heart failure patients received CRT-Ds with Home Monitoring option. Data on all deaths and hospitalizations due to cardiovascular reasons and Home Monitoring data were collected prospectively during 1-year follow-up to develop a predictive algorithm with a predefined specificity of 99.5%. Seven parameters were included in the algorithm: mean heart rate over 24 h, heart rate at rest, patient activity, frequency of ventricular extrasystoles, atrial–atrial intervals (heart rate variability), right ventricular pacing impedance, and painless shock impedance. The algorithm was developed using a 25-day monitoring window ending 3 days before hospitalization or death. While the retrospective sensitivities of the individual parameters ranged from 23.6 to 50.0%, the combination of all parameters was 65.4% sensitive in detecting cardiovascular hospitalizations and deaths with 99.5% specificity (corresponding to 1.83 false-positive detections per patient-year of follow-up). The estimated relative risk of an event was 7.15-fold higher after a positive predictor finding than after a negative predictor finding. Conclusion We developed an automated algorithm for dynamic prediction of cardiovascular events in patients treated with CRT-D devices capable of daily transmission of their diagnostic data via Home Monitoring. This tool may increase patients’ quality of life and reduce morbidity, mortality, and health economic burden, it now warrants prospective studies

    How Similar Are the Mice to Men? Between-Species Comparison of Left Ventricular Mechanics Using Strain Imaging

    Get PDF
    BACKGROUND: While mammalian heart size maintains constant proportion to whole body size, scaling of left ventricular (LV) function parameters shows a more complex scaling pattern. We used 2-D speckle tracking strain imaging to determine whether LV myocardial strains and strain rates scale to heart size. METHODS: We studied 18 mice, 15 rats, 6 rabbits, 12 dogs and 20 human volunteers by 2-D echocardiography. Relationship between longitudinal or circumferential strains/strain rates (S(Long)/SR(Long), S(Circ)/SR(Circ)), and LV end-diastolic volume (EDV) or mass were assessed by the allometric (power-law) equation Y = kM(β). RESULTS: Mean LV mass in individual species varied from 0.038 to 134 g, LV EDV varied from 0.015 to 102 ml, while RR interval varied from 81 to 1090 ms. While S(Long) increased with increasing LV EDV or mass (β values 0.047±0.006 and 0.051±0.005, p<0.0001 vs. 0 for both) S(Circ) was unchanged (p = NS for both LV EDV or mass). Systolic and diastolic SR(Long) and SR(Circ) showed inverse correlations to LV EDV or mass (p<0.0001 vs. 0 for all comparisons). The ratio between S(Long) and S(Circ) increased with increasing values of LV EDV or mass (β values 0.039±0.010 and 0.040±0.011, p>0.0003 for both). CONCLUSIONS: While S(Circ) is unchanged, S(Long) increases with increasing heart size, indicating that large mammals rely more on long axis contribution to systolic function. SR(Long) and SR(Circ), both diastolic and systolic, show an expected decrease with increasing heart size

    A Kinematic Approach for Efficient and Robust Simulation of the Cardiac Beating Motion

    Get PDF
    Computer simulation techniques for cardiac beating motions potentially have many applications and a broad audience. However, most existing methods require enormous computational costs and often show unstable behavior for extreme parameter sets, which interrupts smooth simulation study and make it difficult to apply them to interactive applications. To address this issue, we present an efficient and robust framework for simulating the cardiac beating motion. The global cardiac motion is generated by the accumulation of local myocardial fiber contractions. We compute such local-to-global deformations using a kinematic approach; we divide a heart mesh model into overlapping local regions, contract them independently according to fiber orientation, and compute a global shape that satisfies contracted shapes of all local regions as much as possible. A comparison between our method and a physics-based method showed that our method can generate motion very close to that of a physics-based simulation. Our kinematic method has high controllability; the simulated ventricle-wall-contraction speed can be easily adjusted to that of a real heart by controlling local contraction timing. We demonstrate that our method achieves a highly realistic beating motion of a whole heart in real time on a consumer-level computer. Our method provides an important step to bridge a gap between cardiac simulations and interactive applications

    Prevalence of Symptomatic Heart Failure with Reduced and with Normal Ejection Fraction in an Elderly General Population-The CARLA Study

    Get PDF
    Background/Objectives: Chronic heart failure (CHF) is one of the most important public health concerns in the industrialized world having increasing incidence and prevalence. Although there are several studies describing the prevalence of heart failure with reduced ejection fraction (HFREF) and heart failure with normal ejection fraction (HFNEF) in selected populations, there are few data regarding the prevalence and the determinants of symptomatic heart failure in the general population. Methods: Cross-sectional data of a population-based German sample (1,779 subjects aged 45-83 years) were analyzed to determine the prevalence and determinants of chronic SHF and HFNEF defined according to the European Society of Cardiology using symptoms, echocardiography and serum NT-proBNP. Prevalence was age-standardized to the German population as of December 31st, 2005. Results: The overall age-standardized prevalence of symptomatic CHF was 7.7% (95%CI 6.0-9.8) for men and 9.0% (95%CI 7.0-11.5) for women. The prevalence of CHF strongly increased with age from 3.0% among 45-54- year-old subjects to 22.0% among 75-83- year-old subjects. Symptomatic HFREF could be shown in 48% (n = 78), symptomatic HFNEF in 52% (n = 85) of subjects with CHF. The age-standardized prevalence of HFREF was 3.8 % (95%CI 2.4-5.8) for women and 4.6 % (95%CI 3.6-6.3) for men. The age-standardized prevalence of HFNEF for women and men was 5.1 % (95%CI 3.8-7.0) and 3.0 % (95%CI 2.1-4.5), respectively. Persons with CHF were more likely to have hypertension (PR = 3.4; 95%CI 1.6-7.3) or to have had a previous myocardial infarction (PR = 2.5, 95%CI 1.8-3.5). Conclusion: The prevalence of symptomatic CHF appears high in this population compared with other studies. While more women were affected by HFNEF than men, more male subjects suffered from HFREF. The high prevalence of symptomatic CHF seems likely to be mainly due to the high prevalence of cardiovascular risk factors in this population

    Differential cross section measurements for the production of a W boson in association with jets in proton–proton collisions at √s = 7 TeV

    Get PDF
    Measurements are reported of differential cross sections for the production of a W boson, which decays into a muon and a neutrino, in association with jets, as a function of several variables, including the transverse momenta (pT) and pseudorapidities of the four leading jets, the scalar sum of jet transverse momenta (HT), and the difference in azimuthal angle between the directions of each jet and the muon. The data sample of pp collisions at a centre-of-mass energy of 7 TeV was collected with the CMS detector at the LHC and corresponds to an integrated luminosity of 5.0 fb[superscript −1]. The measured cross sections are compared to predictions from Monte Carlo generators, MadGraph + pythia and sherpa, and to next-to-leading-order calculations from BlackHat + sherpa. The differential cross sections are found to be in agreement with the predictions, apart from the pT distributions of the leading jets at high pT values, the distributions of the HT at high-HT and low jet multiplicity, and the distribution of the difference in azimuthal angle between the leading jet and the muon at low values.United States. Dept. of EnergyNational Science Foundation (U.S.)Alfred P. Sloan Foundatio