344 research outputs found

    Symptomatic snapping knee from biceps femoris tendon subluxation: an unusual case of lateral pain in a marathon runner

    Get PDF
    Snapping biceps femoris syndrome is an uncommon cause of lateral knee pain and may be difficult to diagnose, resulting in unsuccessful surgical intervention. In this report, we present an unusual case of a 37-year-old male marathon runner with unilateral snapping knee secondary to dislocation of the long head of the biceps femoris over the fibular head during knee flexion. The pain was great enough to interfere with his ability to practice sport. Possible causes of symptomatic snapping knee include multiple intra-articular or extra-articular pathology. Biceps femoris snapping over the fibular head is a rare condition. Reported causes include an anomalous insertion of the tendon into the tibia, trauma, and fibular-head abnormality. However, none of those conditions accounted for his symptoms. Failing conservative treatment, the patient underwent surgery for partial resection of the fibular head, with subsequent sudden resolution of symptoms and return to sport. Accurate knowledge and management of this rare condition is mandatory to avoid inappropriate therapy and unnecessary surgical procedures

    Lutein supplementation in retinitis pigmentosa: PC-based vision assessment in a randomized double-masked placebo-controlled clinical trial [NCT00029289]

    Get PDF
    BACKGROUND: There is no generally accepted medical or surgical treatment to stop the progressive course of retinitis pigmentosa. Previous studies have suggested lutein as a potential treatment with positive effects on macular pigment density. The objective of this study was to examine the effect of lutein supplementation on preservation of visual function in patients with retinitis pigmentosa (RP) METHODS: In a double-masked randomized placebo-controlled phase I/II clinical trial with a cross-over design, 34 adult patients with RP were randomized to two groups. One group, consisted of 16 participants, received lutein supplementation (10 mg/d for 12 wks followed by 30 mg/d) for the first 24 weeks and then placebo for the following 24 weeks, while the other group included 18 participants for whom placebo (24 weeks) was administered prior to lutein. Visual acuity, contrast sensitivity, and central visual field were measured at different illumination levels at baseline and every week using a PC-based test at home. RESULTS: For visual acuity (VA) at normal illumination level, treatment with lutein reduced logMAR, i.e. improved VA, but this effect was not statistically significant. The changes in normal (100%), low (4%), and very low (0.1%) illumination log CS were not statistically significant (p-values: 0.34, 0.23, and 0.32, respectively). Lutein had a statistically significant effect on visual field (p-value: 0.038) and this effect increased in the model assuming a 6-week delay in effect of lutein. Comparing the development of vision measures against the natural loss expected to occur over the course of 48 weeks, most measures showed reduced decline, and these reductions were significant for normal illumination VA and CS. CONCLUSION: These results suggest that lutein supplementation improves visual field and also might improve visual acuity slightly, although these results should be interpreted cautiously. As a combined phase I and II clinical trial, this study demonstrated the efficacy and safety of lutein supplementation

    Arthroscopic evaluation of the ACL double bundle structure

    Get PDF
    In order to describe the arthroscopic presence of the double bundle structure and to evaluate the value of different portals in knee arthroscopy, we assessed the AM and PL bundle anatomy. We prospectively examined the knees of 60 patients undergoing arthroscopic surgery for pathology unrelated to the ACL. Arthroscopy was performed in a two portal technique using an anterolateral (ALP) and an anteromedial (AMP) portal. With the arthroscope in the ALP, we could distinguish an AM and PL bundle in 28%. Switching the arthroscope to the AMP, differentiation of the bundles was possible in 67%. In all remaining cases visualization of the PL bundle was possible after retraction of the AM bundle. Use of AMP increased visualization of the PL bundle. It seems reasonable to perform arthroscopy for ACL reconstruction with the arthroscope in the AMP and to establish an additional medial working portal to increase the visualization of the femoral ACL insertion sites for optimal femoral tunnel placement

    New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>This report presents a new imaging technique for non-invasive study of six degrees of freedom (DOF) knee kinematics during treadmill gait.</p> <p>Materials and methods</p> <p>A treadmill was integrated into a dual fluoroscopic imaging system (DFIS) to formulate a gait analysis system. To demonstrate the application of the system, a healthy subject walked on the treadmill at four different speeds (1.5, 2.0, 2.5 and 3.0 MPH) while the DFIS captured the knee motion during three strides under each speed. Characters of knee joint motion were analyzed in 6DOF during the treadmill walking.</p> <p>Results</p> <p>The speed of the knee motion was lower than that of the treadmill. Flexion amplitudes increased with increasing walking speed. Motion patterns in other DOF were not affected by increase in walking speed. The motion character was repeatable under each treadmill speed.</p> <p>Conclusion</p> <p>The presented technique can be used to accurately measure the 6DOF knee kinematics at normal walking speeds.</p

    The Time Course of Segmentation and Cue-Selectivity in the Human Visual Cortex

    Get PDF
    Texture discontinuities are a fundamental cue by which the visual system segments objects from their background. The neural mechanisms supporting texture-based segmentation are therefore critical to visual perception and cognition. In the present experiment we employ an EEG source-imaging approach in order to study the time course of texture-based segmentation in the human brain. Visual Evoked Potentials were recorded to four types of stimuli in which periodic temporal modulation of a central 3° figure region could either support figure-ground segmentation, or have identical local texture modulations but not produce changes in global image segmentation. The image discontinuities were defined either by orientation or phase differences across image regions. Evoked responses to these four stimuli were analyzed both at the scalp and on the cortical surface in retinotopic and functional regions-of-interest (ROIs) defined separately using fMRI on a subject-by-subject basis. Texture segmentation (tsVEP: segmenting versus non-segmenting) and cue-specific (csVEP: orientation versus phase) responses exhibited distinctive patterns of activity. Alternations between uniform and segmented images produced highly asymmetric responses that were larger after transitions from the uniform to the segmented state. Texture modulations that signaled the appearance of a figure evoked a pattern of increased activity starting at ∌143 ms that was larger in V1 and LOC ROIs, relative to identical modulations that didn't signal figure-ground segmentation. This segmentation-related activity occurred after an initial response phase that did not depend on the global segmentation structure of the image. The two cue types evoked similar tsVEPs up to 230 ms when they differed in the V4 and LOC ROIs. The evolution of the response proceeded largely in the feed-forward direction, with only weak evidence for feedback-related activity

    Rotational knee laxity: Reliability of a simple measurement device in vivo

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Double bundle ACL reconstruction has been demonstrated to decrease rotational knee laxity. However, there is no simple, commercially-available device to measure knee rotation. The investigators developed a simple, non-invasive device to measure knee rotation. In conjunction with a rigid boot to rotate the tibia and a force/moment sensor to allow precise determination of torque about the knee, a magnetic tracking system measures the axial rotation of the tibia with respect to the femur. This device has been shown to have acceptable levels of test re-test reliability to measure knee rotation in cadaveric knees.</p> <p>Methods</p> <p>The objective of this study was to determine reliability of the device in measuring knee rotation of human subjects. Specifically, the intra-tester reliability within a single testing session, test-retest reliability between two testing sessions, and inter-tester reliability were assessed for 11 male subjects with normal knees.</p> <p>Results</p> <p>The 95% confidence interval for rotation was less than 5° for intra-tester, test-retest, and inter-tester reliability, and the standard error of measurement for the differences between left and right knees was found to be less than 3°.</p> <p>Conclusion</p> <p>It was found that the knee rotation measurements obtained with this device have acceptable limits of reliability for clinical use and interpretation.</p

    More resistant tendons obtained from the association of Heteropterys aphrodisiaca and endurance training

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Popular Brazilian medicine uses <it>Heteropterys aphrodisiaca </it>infusion as a tonic or stimulant, for the treatment of nervous debility and breakdown and for muscle and bone weakness. This study investigated the effects of <it>Heteropterys aphrodisiaca </it>infusion on the tendon properties and extracellular matrix of rats under endurance training.</p> <p>Methods</p> <p>Wistar rats were grouped as follows: CS- control sedentary, HS- <it>H. aphrodisiaca </it>sedentary, CT-control trained, HT- <it>H. aphrodisiaca </it>trained. The training protocol consisted in running on a motorized treadmill, five times a week, with weekly increase in treadmill speed and duration. Control groups received water while the HS and HT groups received <it>H. aphrodisiaca </it>infusion, daily, by gavage for the 8 weeks of training. Achilles tendons were frozen for biochemical and biomechanical analysis or preserved in Karnovsky's fixative, then processed for histomorphological analysis with light microscopy.</p> <p>Results</p> <p>Biomechanical analysis showed significant increase in maximum load, maximum stress, modulus of elasticity and stiffness of the HT animals' tendons. The metalloproteinase-2 activity was reduced in the HT group. The compression region of HT animals' tendons had a stronger and more intense metachromasy, which suggests an increase in glycosaminoglycan concentration in this region of the tendon. The most intense birefringence was observed in both compression and tension regions of HT animals' tendons, which may indicate a higher organizational level of collagen bundles. The hydroxyproline content increased in the HT group.</p> <p>Conclusions</p> <p>The association of endurance training with <it>H. aphrodisiaca </it>resulted in more organized collagen bundles and more resistant tendons to support higher loads from intense muscle contraction. Despite the clear anabolic effects of <it>Heteropterys aphrodisiaca </it>and the endurance exercise association, no side effects were observed, such as those found for synthetic anabolic androgenic steroids.</p

    Reconstruction versus conservative treatment after rupture of the anterior cruciate ligament: cost effectiveness analysis

    Get PDF
    BACKGROUND: The decision whether to treat conservatively or reconstruct surgically a torn anterior cruciate ligament (ACL) is an ongoing subject of debate. The high prevalence and associated public health burden of torn ACL has led to continuous efforts to determine the best therapeutic approach. A critical evaluation of benefits and expenditures of both treatment options as in a cost effectiveness analysis seems well-suited to provide valuable information for treating physicians and healthcare policymakers. METHODS: A literature review identified four of 7410 searched articles providing sufficient outcome probabilities for the two treatment options for modeling. A transformation key based on the expert opinions of 25 orthopedic surgeons was used to derive utilities from available evidence. The cost data for both treatment strategies were based on average figures compiled by Orthopaedic University Hospital Balgrist and reinforced by Swiss national statistics. A decision tree was constructed to derive the cost-effectiveness of each strategy, which was then tested for robustness using Monte Carlo simulation. RESULTS: Decision tree analysis revealed a cost effectiveness of 16,038 USD/0.78 QALY for ACL reconstruction and 15,466 USD/0.66 QALY for conservative treatment, implying an incremental cost effectiveness of 4,890 USD/QALY for ACL reconstruction. Sensitivity analysis of utilities did not change the trend. CONCLUSION: ACL reconstruction for reestablishment of knee stability seems cost effective in the Swiss setting based on currently available evidence. This, however, should be reinforced with randomized controlled trials comparing the two treatment strategies

    Observation of associated near-side and away-side long-range correlations in √sNN=5.02  TeV proton-lead collisions with the ATLAS detector

    Get PDF
    Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02  TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1  Όb-1 of data as a function of transverse momentum (pT) and the transverse energy (ÎŁETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∌0) correlation that grows rapidly with increasing ÎŁETPb. A long-range “away-side” (Δϕ∌π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ÎŁETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ÎŁETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos⁥2Δϕ modulation for all ÎŁETPb ranges and particle pT
    • 

    corecore