10 research outputs found

    Noncontact electrical metrology of Cu/low-k interconnect for semiconductor production wafers

    Full text link
    We have demonstrated a technique capable of in-line measurement of dielectric constant of low-k interconnect films on patterned wafers utilizing a test key of ~50x50 \mu m in size. The test key consists of a low-k film backed by a Cu grid with >50% metal pattern density and <250 nm pitch, which is fully compatible with the existing dual-damascene interconnect manufacturing processes. The technique is based on a near-field scanned microwave probe and is noncontact, noninvasive, and requires no electrical contact to or grounding of the wafer under test. It yields <0.3% precision and 2% accuracy for the film dielectric constant

    A near-field scanned microwave probe for spatially localized electrical metrology

    Full text link
    We have developed a near-field scanned microwave probe with a sampling volume of approximately 10 micron in diameter, which is the smallest one achieved in near-field microwave microscopy. This volume is defined to confine close to 100 percent of the probe net sampling reactive energy, thus making the response virtually independent on the sample properties outside of this region. The probe is formed by a 4 GHz balanced stripline resonator with a few-micron tip size. It provides non-contact, non-invasive measurement and is uniquely suited for spatially localized electrical metrology applications, e.g. on semiconductor production wafers.Comment: 6 pages, 3 figures, submitted to Appl. Phys. Let

    Photography-based taxonomy is inadequate, unnecessary, and potentially harmful for biological sciences

    Get PDF
    The question whether taxonomic descriptions naming new animal species without type specimen(s) deposited in collections should be accepted for publication by scientific journals and allowed by the Code has already been discussed in Zootaxa (Dubois & NemĂ©sio 2007; Donegan 2008, 2009; NemĂ©sio 2009a–b; Dubois 2009; Gentile & Snell 2009; Minelli 2009; Cianferoni & Bartolozzi 2016; Amorim et al. 2016). This question was again raised in a letter supported by 35 signatories published in the journal Nature (Pape et al. 2016) on 15 September 2016. On 25 September 2016, the following rebuttal (strictly limited to 300 words as per the editorial rules of Nature) was submitted to Nature, which on 18 October 2016 refused to publish it. As we think this problem is a very important one for zoological taxonomy, this text is published here exactly as submitted to Nature, followed by the list of the 493 taxonomists and collection-based researchers who signed it in the short time span from 20 September to 6 October 2016

    Megahertz-rate Ultrafast X-ray Scattering and Holographic Imaging at the European XFEL

    No full text
    13 pages, 5 figures. Supplementary Information as ancillary fileThe advent of X-ray free-electron lasers (XFELs) has revolutionized fundamental science, from atomic to condensed matter physics, from chemistry to biology, giving researchers access to X-rays with unprecedented brightness, coherence, and pulse duration. All XFEL facilities built until recently provided X-ray pulses at a relatively low repetition rate, with limited data statistics. Here, we present the results from the first megahertz repetition rate X-ray scattering experiments at the Spectroscopy and Coherent Scattering (SCS) instrument of the European XFEL. We illustrate the experimental capabilities that the SCS instrument offers, resulting from the operation at MHz repetition rates and the availability of the novel DSSC 2D imaging detector. Time-resolved magnetic X-ray scattering and holographic imaging experiments in solid state samples were chosen as representative, providing an ideal test-bed for operation at megahertz rates. Our results are relevant and applicable to any other non-destructive XFEL experiments in the soft X-ray range
    corecore