8 research outputs found

    Ultra-High Carrier Mobilities in Ferroelectric Domain Wall Corbino Cones at Room Temperature

    Get PDF
    Recently, electrically conducting heterointerfaces between dissimilar band-insulators (such as lanthanum aluminate and strontium titanate) have attracted considerable research interest. Charge transport has been thoroughly explored and fundamental aspects of conduction firmly established. Perhaps surprisingly, similar insights into conceptually much simpler conducting homointerfaces, such as the domain walls that separate regions of different orientations of electrical polarisation within the same ferroelectric band-insulator, are not nearly so well-developed. Addressing this disparity, we herein report magnetoresistance in approximately conical 180° charged domain walls, which occur in partially switched ferroelectric thin film single crystal lithium niobate. This system is ideal for such measurements: firstly, the conductivity difference between domains and domain walls is extremely and unusually large (a factor of at least 1013) and hence currents driven through the thin film, between planar top and bottom electrodes, are overwhelmingly channelled along the walls; secondly, when electrical contact is made to the top and bottom of the domain walls and a magnetic field is applied along their cone axes (perpendicular to the thin film surface), then the test geometry mirrors that of a Corbino disc, which is a textbook arrangement for geometric magnetoresistance measurement. Our data imply carriers at the domain walls with extremely high room temperature Hall mobilities of up to ~ 3,700cm2V-1s-1. This is an unparalleled value for oxide interfaces (and for bulk oxides too) and is most comparable to mobilities in other systems typically seen at cryogenic, rather than at room, temperature

    Anisotropic, meandering domain microstructure in the improper ferroelectric CsNbW2O9

    Get PDF
    S.J.M acknowledges the EPSRC-funded CDT in Photonic Integration and Advanced Data Storage (EP/L015323/1) for his PhD studentship under which the work at the University of Glasgow was carried out. The work carried out at Queen’s University Belfast and the University of St Andrews was carried out as part of an EPSRC-funded collaboration (EP/P02453X/1 and EP/P024637/1).The improper ferroelectric CsNbW2O9 has recently been highlighted as the first material outside the manganite family to exhibit a similar meandering, six-fold domain structure to that responsible for enhanced and diminished conduction at charged domain walls in the rare earth manganites. While there is no current evidence for variation in domain wall conduction relative to bulk in CsNbW2O9, the similarities in microstructure strongly suggest that charged domain walls are present in this material. Herein, we report a comprehensive study of the domain microstructure of CsNbW2O9 using both piezoresponse force microscopy and transmission electron microscopy to reveal that there are, in fact, clear distinctions in the domain structure of the two systems. Constraints arising from the crystal structure of CsNbW2O9, namely, the connectivity of the BO6 polyhedra and atomic displacements occurring purely along the c axis, mean that domain walls preferentially run parallel to the c direction (the polar axis of the material) and thus remain uncharged. The characteristic cloverleaf domain structure reminiscent of the manganites is still present, however, the structure meanders predominantly in the ab plane and, therefore, appears differently depending on the projection direction from which it is viewed. As a result of this microstructural constraint, charged domain walls are not prevalent in this material.Publisher PDFPeer reviewe

    Anisotropic, meandering domain microstructure in the improper ferroelectric CsNbW<sub>2</sub>O<sub>9</sub>

    No full text
    The improper ferroelectric CsNbW2O9 has recently been highlighted as the first material outside the manganite family to exhibit a similar meandering, six-fold domain structure to that responsible for enhanced and diminished conduction at charged domain walls in the rare earth manganites. While there is no current evidence for variation in domain wall conduction relative to bulk in CsNbW2O9, the similarities in microstructure strongly suggest that charged domain walls are present in this material. Herein, we report a comprehensive study of the domain microstructure of CsNbW2O9 using both piezoresponse force microscopy and transmission electron microscopy to reveal that there are, in fact, clear distinctions in the domain structure of the two systems. Constraints arising from the crystal structure of CsNbW2O9, namely, the connectivity of the BO6 polyhedra and atomic displacements occurring purely along the c axis, mean that domain walls preferentially run parallel to the c direction (the polar axis of the material) and thus remain uncharged. The characteristic cloverleaf domain structure reminiscent of the manganites is still present, however, the structure meanders predominantly in the ab plane and, therefore, appears differently depending on the projection direction from which it is viewed. As a result of this microstructural constraint, charged domain walls are not prevalent in this material

    Ultrahigh carrier mobilities in ferroelectric domain wall Corbino cones at room temperature

    Get PDF
    Recently, electrically conducting heterointerfaces between dissimilar band insulators (such as lanthanum aluminate and strontium titanate) have attracted considerable research interest. Charge transport and fundamental aspects of conduction have been thoroughly explored. Perhaps surprisingly, similar studies on conceptually much simpler conducting homointerfaces, such as domain walls, are not nearly so well developed. Addressing this disparity, magnetoresistance is herein reported in approximately conical 180°charged domain walls, in partially switched ferroelectric thin-film single?crystal lithium niobate. This system is ideal for such measurements: first, the conductivity difference between domains and domain walls is unusually large (a factor of 1013) and hence currents driven through the thin film, between planar top and bottom electrodes, are overwhelmingly channeled along the walls; second, when electrical contact is made to the top and bottom of the domain walls and a magnetic field is applied along their cone axes, then the test geometry mirrors that of a Corbino disk: a textbook arrangement for geometric magnetoresistance measurement. Data imply carriers with extremely high room-temperature Hall mobilities of up to ≈3700 cm2  V−1  s−1. This is an unparalleled value for oxide interfaces (and for bulk oxides) comparable to mobilities in other systems seen at cryogenic, rather than at room, temperature.</p

    Elective cancer surgery in COVID-19-free surgical pathways during the SARS-CoV-2 pandemic : an international, multicenter, comparative cohort study

    No full text
    PURPOSE As cancer surgery restarts after the first COVID-19 wave, health care providers urgently require data to determine where elective surgery is best performed. This study aimed to determine whether COVID-19-free surgical pathways were associated with lower postoperative pulmonary complication rates compared with hospitals with no defined pathway. PATIENTS AND METHODS This international, multicenter cohort study included patients who underwent elective surgery for 10 solid cancer types without preoperative suspicion of SARS-CoV-2. Participating hospitals included patients from local emergence of SARS-CoV-2 until April 19, 2020. At the time of surgery, hospitals were defined as having a COVID-19-free surgical pathway (complete segregation of the operating theater, critical care, and inpatient ward areas) or no defined pathway (incomplete or no segregation, areas shared with patients with COVID-19). The primary outcome was 30-day postoperative pulmonary complications (pneumonia, acute respiratory distress syndrome, unexpected ventilation). RESULTS Of 9,171 patients from 447 hospitals in 55 countries, 2,481 were operated on in COVID-19-free surgical pathways. Patients who underwent surgery within COVID-19-free surgical pathways were younger with fewer comorbidities than those in hospitals with no defined pathway but with similar proportions of major surgery. After adjustment, pulmonary complication rates were lower with COVID-19-free surgical pathways (2.2% v 4.9%; adjusted odds ratio [aOR], 0.62; 95% CI, 0.44 to 0.86). This was consistent in sensitivity analyses for low-risk patients (American Society of Anesthesiologists grade 1/2), propensity score-matched models, and patients with negative SARS-CoV-2 preoperative tests. The postoperative SARS-CoV-2 infection rate was also lower in COVID-19-free surgical pathways (2.1% v 3.6%; aOR, 0.53; 95% CI, 0.36 to 0.76). CONCLUSION Within available resources, dedicated COVID-19-free surgical pathways should be established to provide safe elective cancer surgery during current and before future SARS-CoV-2 outbreaks

    Elective Cancer Surgery in COVID-19–Free Surgical Pathways During the SARS-CoV-2 Pandemic: An International, Multicenter, Comparative Cohort Study

    No full text

    Delaying surgery for patients with a previous SARS-CoV-2 infection

    Get PDF
    Not availabl
    corecore