251 research outputs found

    Modeling the Pion and Kaon Form Factors in the Timelike Region

    Full text link
    New, accurate measurements of the pion and kaon electromagnetic form factors are expected in the near future from experiments at electron-positron colliders,using the radiative return method. We construct a model for the timelike pion electromagnetic form factor, that is valid also at momentum transfers far above the ρ\rho resonance. The ansatz is based on vector dominance and includes a pattern of radial excitations expected from dual resonance models.The form factor is fitted to the existing data in the timelike region, continued to the spacelike region and compared with the measurements there and with the QCD predictions. Furthermore, the model is extended to the kaon electromagnetic form factor. Using isospin and SU(3)-flavour symmetry relations we extract the isospin-one contribution and predict the kaon weak form factor accessible in semileptonic τ\tau decays.Comment: 31 pages, 7 figures,latex, one reference changed, version to appear in Eur.Phys.J

    Early discontinuation of endocrine therapy for breast cancer: Who is at risk in clinical practice?

    Get PDF
    Purpose: Despite evidence supporting at least five years of endocrine therapy for early breast cancer, many women discontinue therapy early. We investigated the impact of initial therapy type and specific comorbidities on discontinuation of endocrine therapy in clinical practice. Methods We identified women in a population-based cohort with a diagnosis of early breast cancer and an incident dispensing of anastrozole, letrozole or tamoxifen from 2003-2008 (N = 1531). Pharmacy and health service data were used to determine therapy duration, treatment for pre-existing and post-initiation comorbidities (anxiety, depression, hot flashes, musculoskeletal pain, osteoporosis, vaginal atrophy), demographic and other clinical characteristics. Time to discontinuation of initial, and any, endocrine therapy was calculated. Cox regression determined the association of different characteristics on early discontinuation. Results Initial endocrine therapy continued for a median of 2.2 years and any endocrine therapy for 4.8 years. Cumulative probability of discontinuing any therapy was 17% after one year and 58% by five years. Initial tamoxifen, pre-existing musculoskeletal pain and newly-treated anxiety predicted shorter initial therapy but not discontinuation of any therapy. Early discontinuation of any therapy was associated with newly-treated hot flashes (HR = 2.1, 95%CI = 1.3-3.3), not undergoing chemotherapy (HR = 1.4, 95%CI = 1.1-1.8) and not undergoing mastectomy (HR = 1.5, 95%CI = 1.2-1.8). Conclusions Less than half of women completed five years of endocrine therapy. Women at greatest risk of stopping any therapy early were those with newly-treated hot flashes, no initial chemotherapy, or no initial mastectomy. This suboptimal use means that the reductions in recurrence demonstrated in clinical trials may not be realised in practice

    Acceptability of a Positive Parenting Programme on a Mother and Baby Unit: Q-Methodology with Staff

    Get PDF
    The Baby Triple P Positive Parenting Programme, a new addition to the established Triple P programmes, is currently being considered for a trial in a Mother and Baby Unit with the aim of exploring its benefits to mothers presenting with severe mental illness. The aim of the current study was to investigate staff views of the acceptability and feasibility of a parenting programme such as the Baby Triple P Positive Parenting Programme in a Mother and Baby Unit. Q-methodology, using an 88-item Q-sort, was employed to explore the opinions of 16 staff working in a Mother and Baby Unit in the North West of England. Results obtained from the Q-sort analysis identified two distinct factors: (1) staff qualified acceptance and (2) systemic approach/systemic results. Preliminary findings indicate that staff perceived Baby Triple P to be an acceptable and feasible intervention for the Mother and Baby Unit setting and that mothers on the unit would be open and receptive to the programme. Further research is required to expand these findings and assess the potential for this type of intervention to be used more widely across a number of Mother and Baby Unit settings

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    MARTA: a high-energy cosmic-ray detector concept for high-accuracy muon measurement

    Get PDF
    A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used in air shower arrays. The combination of the two detectors in a single, compact detector unit provides a unique measurement that opens rich possibilities in the study of air showers.Peer Reviewe

    Methods used for successful follow-up in a large scale national cohort study in Thailand

    Get PDF
    Background: Ensuring successful follow-up is essential when conducting a prospective cohort study. Most existing literature reviewing methods to ensure a high response rate is based on experience in developed nations. Findings: We report our 4-year follow-up success for a national cohort study examining the health transition underway in Thailand. We began the cohort study in 2005 with a baseline postal questionnaire sent to all 200,000 Thais enrolled as distance learning students at Sukhothai Thammathirat Open University and residing all over Thailand; 87,134 or 44% of the students responded. Subsequently we used University and national media to inform cohort members of study progress. Also, we prepared a health book with study results and health advice which was distributed to all cohort members. After 4 years we repeated the survey and achieved a 71% response rate. In this paper we report the methods used to achieve this response The initial follow-up mail-out generated a response rate of about 48% reflecting the extensive preparatory work between baseline and follow-up. After 4 rounds of telephone contact (more than 100,000 phone calls) and 4 related mail-out rounds progressively over 16 months an overall response rate was achieved of just over 71% (n = 60,774). The total cost was US$4.06/respondent - 19% for printing, 21% for postage, 14% for tape measures (included in mail-out), 18% for data processing 22% for prizes and 6% for telephone. Conclusions: Many of the methods reported as effective for mail questionnaire and cohort response rates held true for Thailand. These included being associated with a university, incentivating cooperation, follow-up contact, providing a second copy of questionnaire where necessary, and assurance of confidentiality. Telephone contact with the cohort and the small prizes given to responders were particularly important in the Thai context as was Thai leadership of the research team

    Plasma Aβ42/Aβ40 and phospho‐tau217 concentration ratios increase the accuracy of amyloid PET classification in preclinical Alzheimer's disease

    Full text link
    INTRODUCTION: Incorporating blood-based Alzheimer's disease biomarkers such as tau and amyloid beta (Aβ) into screening algorithms may improve screening efficiency. METHODS: Plasma Aβ, phosphorylated tau (p-tau)181, and p-tau217 concentration levels from AHEAD 3-45 study participants were measured using mass spectrometry. Tau concentration ratios for each proteoform were calculated to normalize for inter-individual differences. Receiver operating characteristic (ROC) curve analysis was performed for each biomarker against amyloid positivity, defined by > 20 Centiloids. Mixture of experts analysis assessed the value of including tau concentration ratios into the existing predictive algorithm for amyloid positron emission tomography status. RESULTS: The area under the receiver operating curve (AUC) was 0.87 for Aβ42/Aβ40, 0.74 for phosphorylated variant p-tau181 ratio (p-tau181/np-tau181), and 0.92 for phosphorylated variant p-tau217 ratio (p-tau217/np-tau217). The Plasma Predicted Centiloid (PPC), a predictive model including p-tau217/np-tau217, Aβ42/Aβ40, age, and apolipoprotein E improved AUC to 0.95. DISCUSSION: Including plasma p-tau217/np-tau217 along with Aβ42/Aβ40 in predictive algorithms may streamline screening preclinical individuals into anti-amyloid clinical trials. CLINICALTRIALS: gov Identifier: NCT04468659 HIGHLIGHTS: The addition of plasma phosphorylated variant p-tau217 ratio (p-tau217/np-tau217) significantly improved plasma biomarker algorithms for identifying preclinical amyloid positron emission tomography positivity. Prediction performance at higher NAV Centiloid levels was improved with p-tau217/np-tau217. All models generated for this study are incorporated into the Plasma Predicted Centiloid (PPC) app for public use
    corecore