383 research outputs found

    Assessing the Quality of Reports about Randomized Controlled Trials of Acupuncture Treatment on Diabetic Peripheral Neuropathy

    Get PDF
    BACKGROUND: To evaluate the reports' qualities which are about randomized controlled trials (RCTs) of acupuncture treatment on Diabetic Peripheral Neuropathy (DPN). METHODOLOGY/PRINCIPAL FINDINGS: Eight databases including The Cochrane Library(1993-Sept.,2011), PubMed (1980-Sept., 2011), EMbase (1980-Sept.,2011), SCI Expanded (1998-Sept.,2011), China Biomedicine Database Disc (CBMdisc, 1978-Sept., 2011), China National Knowledge Infrastructure (CNKI, 1979-Sept., 2011 ), VIP (a full text issues database of China, 1989-Sept., 2011), Wan Fang (another full text issues database of China 1998-Sept., 2011) were searched systematically. Hand search for further references was conducted. Language was limited to Chinese and English. We identified 75 RCTs that used acupuncture as an intervention and assessed the quality of these reports with the Consolidated Standards for Reporting of Trials statement 2010 (CONSORT2010) and Standards for Reporting Interventions Controlled Trials of Acupuncture 2010(STRICTA2010). 24 articles (32%) applied the method of random allocation of sequences. No article gave the description of the mechanism of allocation concealment, no experiment applied the method of blinding. Only one article (1.47%) could be identified directly from its title as about the Randomized Controlled Trials, and only 4 articles gave description of the experimental design. No article mentioned the number of cases lost or eliminated. During one experiment, acupuncture syncope led to temporal interruption of the therapy. Two articles (2.94%) recorded the number of needles, and 8 articles (11.76%) mentioned the depth of needle insertion. None of articles reported the base of calculation of sample size, or has any analysis about the metaphase of an experiment or an explanation of its interruption. One (1.47%) mentioned intentional analysis (ITT). CONCLUSIONS/SIGNIFICANCE: The quality of the reports on RCTs of acupuncture for Diabetic Peripheral Neuropathy is moderate to low. The CONSORT2010 and STRICTA2010 should be used to standardize the reporting of RCTs of acupuncture in future

    Penile prosthesis implantation in Chinese patients with severe erectile dysfunction: 10-year experience

    Full text link
    We retrospectively evaluated the clinical outcome of penile prosthesis implantation (PPI) in Chinese patients with severe erectile dysfunction (SED). From July 2000 to December 2011, 224 patients (mean age: 35.9±11.8 years, range: 20–75 years) with SED underwent PPI by experienced surgeon according to standard PPI procedure at our centre. A malleable prosthesis (AMS 650) was implanted in 45 cases (20.1%), and a three-piece inflatable prosthesis (AMS 700 CXM or AMS 700 CXR) was implanted in 179 cases (79.9%). Surgical outcomes, including postoperative complications, clinical efficacy and couple satisfaction, were evaluated over than 6 months postoperatively using medical record abstraction, IIEF-5, quality of life (QoL) scores, and the patient/partner sexual satisfaction score proposed by Bhojwani et al. Of the 224 patients eligible for the study, 201 subjects (89.7%) completed follow-up. All of patients could perform sexual intercourse post PPI with the mean postoperative IIEF-5 and QoL scores were 20.02±2.32 and 5.28±0.76, respectively, which were significantly improved compared with the preoperative scores (6.29±1.5 and 2.13±0.84, P<0.01). Of the 201 men, mechanical malfunction occurred in four cases (2.0%) and three cases were re-implanted new device, and two cases (1.0%) developed a mild curvature of the penis. Scrotal erosion with infection occurred in one case with diabetes mellitus (0.5%) and required complete removal of the implanted AMS 700 CXM. Satisfactory sexual intercourse at least twice per month was reported by 178 men (88.6%), and overall satisfaction with the PPI surgery was reported by 89.0% of men and 82.5% of partners. Patient satisfaction in the three-piece inflatable prosthesis group was higher than in the malleable prosthesis group (P<0.05). Satisfaction, however, between the types of prostheses, did not differ in the partner survey. PPI is a safe and effective treatment option for Chinese patients with SED and experienced surgeon perform PPI according to standard PPI procedure could reduce the postoperative complications of PPI and could improve patient satisfaction ratio and QoL

    Transgenic Cry1Ab Rice Does Not Impact Ecological Fitness and Predation of a Generalist Spider

    Get PDF
    Background: The commercial release of rice genetically engineered to express a Cry1Ab protein from Bacillus thuringiensis (Bt) for control of Lepidoptera in China is a subject of debate. One major point of the debate has focused on the ecological safety of Bt rice on nontarget organisms, especially predators and parasitoids that help control populations of insect pests. Methodology/Principal Findings: A tritrophic bioassay was conducted to evaluate the potential impact of Cry1Abexpressing rice on fitness parameters of a predaceous ground spider (Pardosa pseudoannulata (Bösenberg et Strand)) that had fed on Bt rice-fed brown planthopper (Nilaparvata lugens (Sta˚l)) nymphs. Survival, development time and fecundity of this spider were not different when they were fed with Bt rice-fed or non-Bt rice-fed prey. Furthermore, ELISA and PCR gut assays, as well as a functional response trial, indicated that predation by P. pseudoannulata was not significantly different in Bt rice or non-Bt rice fields. Conclusions/Significance: The transgenic Cry1Ab rice lines tested in this study had no adverse effects on the survival, developmental time and fecundity of P. pseudoannulata in the laboratory or on predation under field conditions. Thi

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter

    Measurement of jet fragmentation into charged particles in pp and PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    Jet fragmentation in pp and PbPb collisions at a centre-of-mass energy of 2.76 TeV per nucleon pair was studied using data collected with the CMS detector at the LHC. Fragmentation functions are constructed using charged-particle tracks with transverse momenta pt > 4 GeV for dijet events with a leading jet of pt > 100 GeV. The fragmentation functions in PbPb events are compared to those in pp data as a function of collision centrality, as well as dijet-pt imbalance. Special emphasis is placed on the most central PbPb events including dijets with unbalanced momentum, indicative of energy loss of the hard scattered parent partons. The fragmentation patterns for both the leading and subleading jets in PbPb collisions agree with those seen in pp data at 2.76 TeV. The results provide evidence that, despite the large parton energy loss observed in PbPb collisions, the partition of the remaining momentum within the jet cone into high-pt particles is not strongly modified in comparison to that observed for jets in vacuum.Comment: Submitted to the Journal of High Energy Physic

    Continuous Regional Arterial Infusion with Fluorouracil and Octreotide Attenuates Severe Acute Pancreatitis in a Canine Model

    Get PDF
    Aim: To investigate the therapeutic effects of fluorouracil (5-Fu) and octreotide (Oct) continuous regional arterial infusion (CRAI,) alone or in combination, was administered in a canine model of severe acute pancreatitis (SAP). Materials and Methods: The animals were divided into five groups; group A (Sham), group B (SAP), group C (SAP and 5-Fu), group D (SAP and Oct), and group E (SAP and 5-Fu + Oct). Levels of amylase, alpha-tumor necrosis factor (TNF-alpha), blood urea nitrogen (BUN), creatinine, thromboxane B2 and 6-keto-prostaglandin F1 alpha were measured both before and after the induction of SAP. Pathologic examination of the pancreas and kidneys was performed after termination of the study. Results: Pathologic changes noted in the pancreas in SAP significantly improved following CRAI with either single or combined administration of 5-Fu and Oct, where combination therapy demonstrated the lowest injury score. All treatment groups had significantly lower levels of serum TNF-alpha and amylase activity (P<0.05), though only groups D and E had a lower BUN level as compared to group B. The plasma thromboxane B-2 level increased in SAP, but the ratio of thromboxane B-2/6-keto-prostaglandin F-1 alpha decreased in the treatment groups, with the combination therapy (group E) demonstrating the lowest ratio as compared to the other 3 experimental groups (P<0.05). Conclusions: The findings in the present study demonstrate an attenuation of SAP in a canine model following CRAI administration with 5-Fu or Oct, alone or in combination
    corecore