755 research outputs found

    Pharmaceutical Properties of Nanoparticulate Formulation Composed of TPGS and PLGA for Controlled Delivery of Anticancer Drug

    Get PDF
    A suitable management of the pharmaceutical property is needed and helpful to design a desired nanoparticulate delivery system, which includes the carrier nature, particle size and size distribution, morphology, surfactant stabiliser according to the technique applied, drug-loading ratio and encapsulation efficiency, surface property, etc. All will influence the in vitro release, in vivo behaviour and tissue distribution of administered particulate drug loaded nanoparticles. The main purpose of the present work was to determine the effect of drug loading ratio when employing TPGS as surfactant stabiliser and/or matrix material to improve the nanoparticulate formulation. The model drug employed was paclitaxel.Singapore-MIT Alliance (SMA

    Current distribution and giant magnetoimpedance in composite wires with helical magnetic anisotropy

    Full text link
    The giant magnetoimpedance effect in composite wires consising of a non-magnetic inner core and soft magnetic shell is studied theoretically. It is assumed that the magnetic shell has a helical anisotropy. The current and field distributions in the composite wire are found by means of a simultaneous solution of Maxwell equations and the Landau-Lifshitz equation. The expressions for the diagonal and off-diagonal impedance are obtained for low and high frequencies. The dependences of the impedance on the anisotropy axis angle and the shell thickness are analyzed. Maximum field sensitivity is shown to correspond to the case of the circular anisotropy in the magnetic shell. It is demonstrated that the optimum shell thickness to obtain maximum impedance ratio is equal to the effective skin depth in the mahnetic material.Comment: 23 pages, 7 figure

    Narrow ridge waveguide high power single mode 1.3-μm InAs/InGaAs ten-layer quantum dot lasers

    Get PDF
    Ten-layer InAs/In0.15Ga0.85As quantum dot (QD) laser structures have been grown using molecular beam epitaxy (MBE) on GaAs (001) substrate. Using the pulsed anodic oxidation technique, narrow (2 μm) ridge waveguide (RWG) InAs QD lasers have been fabricated. Under continuous wave operation, the InAs QD laser (2 × 2,000 μm2) delivered total output power of up to 272.6 mW at 10 °C at 1.3 μm. Under pulsed operation, where the device heating is greatly minimized, the InAs QD laser (2 × 2,000 μm2) delivered extremely high output power (both facets) of up to 1.22 W at 20 °C, at high external differential quantum efficiency of 96%. Far field pattern measurement of the 2-μm RWG InAs QD lasers showed single lateral mode operation

    Efficacy and safety of weekly carfilzomib (70 mg/m2), dexamethasone, and daratumumab (KdD70) is comparable to twice-weekly KdD56 while being a more convenient dosing option : a cross-study comparison of the CANDOR and EQUULEUS studies

    Get PDF
    The regimen of carfilzomib, daratumumab, and dexamethasone (KdD) shows activity in patients with relapsed/refractory multiple myeloma. KdD at the twice-weekly 56 mg/m carfilzomib dose (KdD56) was used in the randomized phase 3 CANDOR study (NCT03158688), whereas KdD at the once-weekly 70 mg/m carfilzomib dose (KdD70) was used in the phase 1 b EQUULEUS study (NCT01998971). We analyzed efficacy data from comparable CANDOR and EQUULEUS patients using inverse probability of treatment weighting (IPTW)-adjusted models. These weights were calculated from propensity scores derived to balance prespecified baseline covariates. The side-by-side and adjusted comparisons showed similar efficacy for overall response rates and progression-free survival in the two groups, with a series of sensitivity analyses showing consistent findings. Safety data were generally consistent with the known safety profiles of each individual drug. Once-weekly KdD70 is comparable to twice-weekly KdD56 in terms of efficacy and safety while being a more convenient dosing option

    Treatment Guidance for Patients With Lung Cancer During the Coronavirus 2019 Pandemic.

    Get PDF
    The global coronavirus disease 2019 pandemic continues to escalate at a rapid pace inundating medical facilities and creating substantial challenges globally. The risk of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in patients with cancer seems to be higher, especially as they are more likely to present with an immunocompromised condition, either from cancer itself or from the treatments they receive. A major consideration in the delivery of cancer care during the pandemic is to balance the risk of patient exposure and infection with the need to provide effective cancer treatment. Many aspects of the SARS-CoV-2 infection currently remain poorly characterized and even less is known about the course of infection in the context of a patient with cancer. As SARS-CoV-2 is highly contagious, the risk of infection directly affects the cancer patient being treated, other cancer patients in close proximity, and health care providers. Infection at any level for patients or providers can cause considerable disruption to even the most effective treatment plans. Lung cancer patients, especially those with reduced lung function and cardiopulmonary comorbidities are more likely to have increased risk and mortality from coronavirus disease 2019 as one of its common manifestations is as an acute respiratory illness. The purpose of this manuscript is to present a practical multidisciplinary and international overview to assist in treatment for lung cancer patients during this pandemic, with the caveat that evidence is lacking in many areas. It is expected that firmer recommendations can be developed as more evidence becomes available

    Generalized (\kappa,\mu)-space forms

    Full text link
    Generalized (\kappa ,\mu)-space forms are introduced and studied. We examine in depth the contact metric case and present examples for all possible dimensions. We also analyse the trans-Sasakian case.Comment: 20 pages, several changes have been done in this versio

    Anisotropic flow of charged hadrons, pions and (anti-)protons measured at high transverse momentum in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}}=2.76 TeV

    Get PDF
    The elliptic, v2v_2, triangular, v3v_3, and quadrangular, v4v_4, azimuthal anisotropic flow coefficients are measured for unidentified charged particles, pions and (anti-)protons in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}} = 2.76 TeV with the ALICE detector at the Large Hadron Collider. Results obtained with the event plane and four-particle cumulant methods are reported for the pseudo-rapidity range η<0.8|\eta|<0.8 at different collision centralities and as a function of transverse momentum, pTp_{\rm T}, out to pT=20p_{\rm T}=20 GeV/cc. The observed non-zero elliptic and triangular flow depends only weakly on transverse momentum for pT>8p_{\rm T}>8 GeV/cc. The small pTp_{\rm T} dependence of the difference between elliptic flow results obtained from the event plane and four-particle cumulant methods suggests a common origin of flow fluctuations up to pT=8p_{\rm T}=8 GeV/cc. The magnitude of the (anti-)proton elliptic and triangular flow is larger than that of pions out to at least pT=8p_{\rm T}=8 GeV/cc indicating that the particle type dependence persists out to high pTp_{\rm T}.Comment: 16 pages, 5 captioned figures, authors from page 11, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/186

    Centrality dependence of charged particle production at large transverse momentum in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm{NN}}} = 2.76 TeV

    Get PDF
    The inclusive transverse momentum (pTp_{\rm T}) distributions of primary charged particles are measured in the pseudo-rapidity range η<0.8|\eta|<0.8 as a function of event centrality in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm{NN}}}=2.76 TeV with ALICE at the LHC. The data are presented in the pTp_{\rm T} range 0.15<pT<500.15<p_{\rm T}<50 GeV/cc for nine centrality intervals from 70-80% to 0-5%. The Pb-Pb spectra are presented in terms of the nuclear modification factor RAAR_{\rm{AA}} using a pp reference spectrum measured at the same collision energy. We observe that the suppression of high-pTp_{\rm T} particles strongly depends on event centrality. In central collisions (0-5%) the yield is most suppressed with RAA0.13R_{\rm{AA}}\approx0.13 at pT=6p_{\rm T}=6-7 GeV/cc. Above pT=7p_{\rm T}=7 GeV/cc, there is a significant rise in the nuclear modification factor, which reaches RAA0.4R_{\rm{AA}} \approx0.4 for pT>30p_{\rm T}>30 GeV/cc. In peripheral collisions (70-80%), the suppression is weaker with RAA0.7R_{\rm{AA}} \approx 0.7 almost independently of pTp_{\rm T}. The measured nuclear modification factors are compared to other measurements and model calculations.Comment: 17 pages, 4 captioned figures, 2 tables, authors from page 12, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/284
    corecore