295 research outputs found

    Can we continue research in splenectomized dogs? Mycoplasma haemocanis: Old problem - New insight

    Get PDF
    We report the appearance of a Mycoplasma haemocanis infection in laboratory dogs, which has been reported previously, yet, never before in Europe. Outbreak of the disease was triggered by a splenectomy intended to prepare the dogs for a hemorrhagic shock study. The clinical course of the dogs was dramatic including anorexia and hemolytic anemia. Treatment included allogeneic transfusion, prednisone, and oxytetracycline. Systematic follow-up (n=12, blood smears, antibody testing and specific polymerase chain reaction) gives clear evidence that persistent eradication of M. haemocanis is unlikely. We, therefore, had to abandon the intended shock study. In the absence of effective surveillance and screening for M. haemocanis, the question arises whether it is prudent to continue shock research in splenectomized dogs. Copyright (C) 2004 S. Karger AG, Basel

    Stabilization of mid-sized silicon nanoparticles by functionalization with acrylic acid

    Get PDF
    We present an enhanced method to form stable dispersions of medium-sized silicon nanoparticles for solar cell applications by thermally induced grafting of acrylic acid to the nanoparticle surface. In order to confirm their covalent attachment on the silicon nanoparticles and to assess the quality of the functionalization, X-ray photoelectron spectroscopy and diffuse reflectance infrared Fourier spectroscopy measurements were carried out. The stability of the dispersion was elucidated by dynamic light scattering and Zeta-potential measurements, showing no sign of degradation for months

    The relationship between perceived service quality and patient willingness to recommend at a national oncology hospital network

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>"Willingness to recommend" questions are being increasingly used to measure and manage patient loyalty. Yet, there is little data in the literature correlating the "willingness to recommend" question with commonly used perceived service quality items in surveys to identify the key drivers of the optimal patient experience. We therefore evaluated the relationship between perceived service quality and subsequent single top box "willingness to recommend" scores among oncology patients.</p> <p>Methods</p> <p>A total of 2018 returning cancer patients treated at Cancer Treatment Centers of America<sup>® </sup>(CTCA) responded to an internally developed service quality questionnaire, which covered the following dimensions: operations and services, treatment and care with a multidisciplinary team and patient endorsements. Items were measured on a 7-point Likert-type scale ranging from "completely dissatisfied" to "completely satisfied." Patient willingness to, "recommend this facility to friends and associates" was measured on an 11-point scale ranging from "not at all likely" to "extremely likely", which was subsequently dichotomized into two categories: top box response (10) versus all others (0-9). The relationship between perceived service quality and "willingness to recommend" was assessed via Kendall's tau b correlation and univariate and multivariate logistic regression.</p> <p>Results</p> <p>Of the 2018 patients, 959 were newly diagnosed while 1059 were previously treated. 902 were males and 1116 females. The mean age was 54.2 years and the most frequent diagnoses were breast (412), lung (294), prostate (260), colorectal (179) and pancreas (169). 1553 patients said they were "extremely likely" to recommend CTCA to friends and associates, resulting in 77% "top box" responses while 465 (23%) responded in all other categories. The key service quality drivers that were statistically significant in the final logistic model were "team helping you understand your medical condition", "staff genuinely caring for you as an individual", "whole person approach to patient care" and "CTCA medical oncologist."</p> <p>Conclusions</p> <p>In this multi-center study, we demonstrate the predictive significance of perceived service quality as it relates to patient willingness to recommend an oncology service provider. This study is unique in reporting on the role of perceived service quality as a predictor of patient willingness to recommend in a large sample of cancer patients.</p

    Determinants of patient satisfaction in ambulatory oncology: a cross sectional study based on the OUT-PATSAT35 questionnaire

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this study was to identify factors associated with satisfaction with care in cancer patients undergoing ambulatory treatment. We investigated associations between patients' baseline clinical and socio-demographic characteristics, as well as self-reported quality of life, and satisfaction with care.</p> <p>Methods</p> <p>Patients undergoing ambulatory chemotherapy or radiotherapy in 2 centres in France were invited, at the beginning of their treatment, to complete the OUT-PATSAT35, a 35 item and 13 scale questionnaire evaluating perception of doctors, nurses and aspects of care organisation. Additionally, for each patient, socio-demographic variables, clinical characteristics and self-reported quality of life using the EORTC QLQ-C30 questionnaire were recorded.</p> <p>Results</p> <p>Among 692 patients included between January 2005 and December 2006, only 6 were non-responders. By multivariate analysis, poor perceived global health strongly predicted dissatisfaction with care (<it>p </it>< 0.0001). Patients treated by radiotherapy (vs patients treated by chemotherapy) reported lower levels of satisfaction with doctors' technical and interpersonal skills, information provided by caregivers, and waiting times. Patients with primary head and neck cancer (vs other localisations), and those living alone were less satisfied with information provided by doctors, and younger patients (< 55 years) were less satisfied with doctors' availability.</p> <p>Conclusions</p> <p>A number of clinical of socio-demographic factors were significantly associated with different scales of the satisfaction questionnaire. However, the main determinant was the patient's global health status, underlining the importance of measuring and adjusting for self-perceived health status when evaluating satisfaction. Further analyses are currently ongoing to determine the responsiveness of the OUT-PATSAT35 questionnaire to changes over time.</p

    Beauty photoproduction measured using decays into muons in dijet events in ep collisions at s\sqrt{s}=318 GeV

    Get PDF
    The photoproduction of beauty quarks in events with two jets and a muon has been measured with the ZEUS detector at HERA using an integrated luminosity of 110 pb1^{- 1}. The fraction of jets containing b quarks was extracted from the transverse momentum distribution of the muon relative to the closest jet. Differential cross sections for beauty production as a function of the transverse momentum and pseudorapidity of the muon, of the associated jet and of xγjetsx_{\gamma}^{jets}, the fraction of the photon's momentum participating in the hard process, are compared with MC models and QCD predictions made at next-to-leading order. The latter give a good description of the data.Comment: 32 pages, 6 tables, 7 figures Table 6 and Figure 7 revised September 200

    The dependence of dijet production on photon virtuality in ep collisions at HERA

    Get PDF
    The dependence of dijet production on the virtuality of the exchanged photon, Q^2, has been studied by measuring dijet cross sections in the range 0 < Q^2 < 2000 GeV^2 with the ZEUS detector at HERA using an integrated luminosity of 38.6 pb^-1. Dijet cross sections were measured for jets with transverse energy E_T^jet > 7.5 and 6.5 GeV and pseudorapidities in the photon-proton centre-of-mass frame in the range -3 < eta^jet <0. The variable xg^obs, a measure of the photon momentum entering the hard process, was used to enhance the sensitivity of the measurement to the photon structure. The Q^2 dependence of the ratio of low- to high-xg^obs events was measured. Next-to-leading-order QCD predictions were found to generally underestimate the low-xg^obs contribution relative to that at high xg^obs. Monte Carlo models based on leading-logarithmic parton-showers, using a partonic structure for the photon which falls smoothly with increasing Q^2, provide a qualitative description of the data.Comment: 35 pages, 6 eps figures, submitted to Eur.Phys.J.

    Search for a narrow charmed baryonic state decaying to D^*+/- p^-/+ in ep collisions at HERA

    Get PDF
    A resonance search has been made in the D^*+/- p^-/+ invariant-mass spectrum with the ZEUS detector at HERA using an integrated luminosity of 126 pb^-1. The decay channels D^*+ -> D^0 pi^+_s -> (K^- pi^+) pi^+_s and D^*+ -> D^0 pi^+_s -> (K^- pi^+ pi^+ pi^-) pi^+_s (and the corresponding antiparticle decays) were used to identify D^*+/- mesons. No resonance structure was observed in the D^*+/- p^-/+ mass spectrum from more than 60000 reconstructed D^*+/- mesons. The results are not compatible with a report of the H1 Collaboration of a charmed pentaquark, Theta^0_c.Comment: 22 pages, 7 figures, 1 table; minor text revisions; 2 references adde

    Search for CP violation in D+→ϕπ+ and D+s→K0Sπ+ decays

    Get PDF
    A search for CP violation in D + → ϕπ + decays is performed using data collected in 2011 by the LHCb experiment corresponding to an integrated luminosity of 1.0 fb−1 at a centre of mass energy of 7 TeV. The CP -violating asymmetry is measured to be (−0.04 ± 0.14 ± 0.14)% for candidates with K − K + mass within 20 MeV/c 2 of the ϕ meson mass. A search for a CP -violating asymmetry that varies across the ϕ mass region of the D + → K − K + π + Dalitz plot is also performed, and no evidence for CP violation is found. In addition, the CP asymmetry in the D+s→K0Sπ+ decay is measured to be (0.61 ± 0.83 ± 0.14)%

    Angular and Current-Target Correlations in Deep Inelastic Scattering at HERA

    Get PDF
    Correlations between charged particles in deep inelastic ep scattering have been studied in the Breit frame with the ZEUS detector at HERA using an integrated luminosity of 6.4 pb-1. Short-range correlations are analysed in terms of the angular separation between current-region particles within a cone centred around the virtual photon axis. Long-range correlations between the current and target regions have also been measured. The data support predictions for the scaling behaviour of the angular correlations at high Q2 and for anti-correlations between the current and target regions over a large range in Q2 and in the Bjorken scaling variable x. Analytic QCD calculations and Monte Carlo models correctly describe the trends of the data at high Q2, but show quantitative discrepancies. The data show differences between the correlations in deep inelastic scattering and e+e- annihilation.Comment: 26 pages including 10 figures (submitted to Eur. J. Phys. C

    Plastisol Foaming Process. Decomposition of the Foaming Agent, Polymer Behavior in the Corresponding Temperature Range and Resulting Foam Properties

    Get PDF
    The decomposition of azodicarbonamide, used as foaming agent in PVC - plasticizer (1/1) plastisols was studied by DSC. Nineteen different plasticizers, all belonging to the ester family, two being polymeric (polyadipates), were compared. The temperature of maximum decomposition rate (in anisothermal regime at 5 K min-1 scanning rate), ranges between 434 and 452 K. The heat of decomposition ranges between 8.7 and 12.5 J g -1. Some trends of variation of these parameters appear significant and are discussed in terms of solvent (matrix) and viscosity effects on the decomposition reactions. The shear modulus at 1 Hz frequency was determined at the temperature of maximum rate of foaming agent decomposition, and differs significantly from a sample to another. The foam density was determined at ambient temperature and the volume fraction of bubbles was used as criterion to judge the efficiency of the foaming process. The results reveal the existence of an optimal shear modulus of the order of 2 kPa that corresponds roughly to plasticizer molar masses of the order of 450 ± 50 g mol-1. Heavier plasticizers, especially polymeric ones are too difficult to deform. Lighter plasticizers such as diethyl phthalate (DEP) deform too easily and presumably facilitate bubble collapse
    corecore