454 research outputs found

    Variation in ambulance call rates for care homes in Torbay, UK

    Get PDF
    Emergency ambulance calls represent one of the routes of emergency hospital admissions from care homes. We aimed to describe the pattern of ambulance call rates from care homes and identify factors predicting those homes calling for an ambulance most frequently. We obtained data from South Western Ambulance Service NHS Foundation Trust on 3138 ambulance calls relating to people aged 65 and over from care homes in the Torbay region between 1/4/12 and 31/7/13. We supplemented this with data from the Care Quality Commission (CQC) website on home characteristics and outcomes of CQC inspections. We used descriptive statistics to identify variation in ambulance call rates for residential and nursing homes and fitted negative binomial regression models to determine if call rates were predicted by home type (nursing versus residential), the five standards in the CQC reports, dementia care status or travel time to hospital. One hundred and forty-six homes (119 residential and 27 nursing) were included in the analysis. The number of calls made ranged from 1 to 99. The median number (IQR; range) of calls per resident per year was 0.51 (0.21 to 0.89; 0.03 to 2.45). Nursing homes had a lower call rate than residential homes (adjusted rate ratio (ARR) 0.29; 95% CI: 0.22 to 0.40 ; p<0.001); care homes failing the quality and suitability of management standard had a lower call rate compared to those who passed (ARR 0.67; 95% CI: 0.50 to 0.90; p=0.006); and homes specialising in dementia had a higher call rate compared to those not specialising (ARR 1.56; 95% CI: 1.23 to 1.96; p<0.001). These findings require replication in other regions to establish their generalisability and further investigation is required to determine the extent to which callrate variability reflects the different needs of resident populations or differences in care home policies and practice

    High temperature measurements and condensed matter analysis of the thermo-physical properties of ThO2

    No full text
    Values are presented for thermal conductivity, specific heat, spectral and total hemispherical emissivity of ThO2 (a potential nuclear fuel material) in a temperature range representative of a nuclear accident - 2000 K to 3050 K. For the first time direct measurements of thermal conductivity have been carried out on ThO2 at such high temperatures, clearly showing the property does not decrease above 2000 K. This could be understood in terms of an electronic contribution (arising from defect induced donor/acceptor states) compensating the degradation of lattice thermal conductivity. The increase in total hemispherical emissivity and visible/near-infrared spectral emissivity is consistent with the formation of donor/acceptor states in the band gap of ThO2. The electronic population of these defect states increases with temperature and hence more incoming photons (in the visible and near-infrared wavelength range) can be absorbed. A solid state physics model is used to interpret the experimental results. Specific heat and thermal expansion coefficient increase at high temperatures due to the formation of defects, in particular oxygen Frenkel pairs. Prior to melting a gradual increase to a maximum value is predicted in both properties. These maxima mark the onset of saturation of oxygen interstitial sites

    Accommodation of tin in tetragonal ZrO2

    Get PDF
    Atomic scale computer simulations using density functional theory were used to investigate the behaviour of tin in the tetragonal phase oxide layer on Zr-based alloys. The Sn×ZrSnZr× defect was shown to be dominant across most oxygen partial pressures, with Sn′′ZrSnZr″ charge compensated by V∙∙OVO•• occurring at partial pressures below 10−31 atm. Insertion of additional positive charge into the system was shown to significantly increase the critical partial pressure at which Sn′′ZrSnZr″ is stable. Recently developed low-Sn nuclear fuel cladding alloys have demonstrated an improved corrosion resistance and a delayed transition compared to Sn-containing alloys, such as Zircaloy-4. The interaction between the positive charge and the tin defect is discussed in the context of alloying additions, such as niobium and their influence on corrosion of cladding alloys

    Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF

    Full text link
    The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described

    Observation of electron-antineutrino disappearance at Daya Bay

    Full text link
    The Daya Bay Reactor Neutrino Experiment has measured a non-zero value for the neutrino mixing angle θ13\theta_{13} with a significance of 5.2 standard deviations. Antineutrinos from six 2.9 GWth_{\rm th} reactors were detected in six antineutrino detectors deployed in two near (flux-weighted baseline 470 m and 576 m) and one far (1648 m) underground experimental halls. With a 43,000 ton-GW_{\rm th}-day livetime exposure in 55 days, 10416 (80376) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to expected number of antineutrinos at the far hall is R=0.940±0.011(stat)±0.004(syst)R=0.940\pm 0.011({\rm stat}) \pm 0.004({\rm syst}). A rate-only analysis finds sin22θ13=0.092±0.016(stat)±0.005(syst)\sin^22\theta_{13}=0.092\pm 0.016({\rm stat})\pm0.005({\rm syst}) in a three-neutrino framework.Comment: 5 figures. Version to appear in Phys. Rev. Let

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented
    corecore