605 research outputs found

    Protocol design and current status of CLIVIT: a randomized controlled multicenter relevance trial comparing clips versus ligatures in thyroid surgery

    Get PDF
    BACKGROUND: Annually, more than 90000 surgical procedures of the thyroid gland are performed in Germany. Strategies aimed at reducing the duration of the surgical procedure are relevant to patients and the health care system especially in the context of reducing costs. However, new techniques for quick and safe hemostasis have to be tested in clinically relevance randomized controlled trials before a general recommendation can be given. The current standard for occlusion of blood vessels in thyroid surgery is ligatures. Vascular clips may be a safe alternative but have not been investigated in a large RCT. METHODS/DESIGN: CLIVIT (Clips versus Ligatures in Thyroid Surgery) is an investigator initiated, multicenter, patient-blinded, two-group parallel relevance randomized controlled trial designed by the Study Center of the German Surgical Society. Patients scheduled for elective resection of at least two third of the gland for benign thyroid disease are eligible for participation. After surgical exploration patients are randomized intraoperatively into either the conventional ligature group, or into the clip group. The primary objective is to test for a relevant reduction in operating time (at least 15 min) when using the clip technique. Since April 2004, 121 of the totally required 420 patients were randomized in five centers. DISCUSSION: As in all trials the different forms of bias have to be considered, and as in this case, a surgical trial, the role of surgical expertise plays a key role, and will be documented and analyzed separately. This is the first randomized controlled multicenter relevance trial to compare different vessel occlusion techniques in thyroid surgery with adequate power and other detailed information about the design as well as framework. If significant, the results might be generalized and may change the current surgical practice

    Meta-analysis of thyroidectomy with ultrasonic dissector versus conventional clamp and tie

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We conducted a systematic review to evaluate the role of Ultrasonic dissector (UAS) versus conventional clamp and tie in thyroidectomy.</p> <p>Materials and methods</p> <p>We searched for all published RCT in into electronic databases. To be included in the analysis, the studies had to compare thyroidectomy with UAS versus conventional vessel ligation and tight (conventional technique = CT). The following outcomes were used to compare the total thyroidectomy group with UAS versus CT group: operative duration, operative blood loss, overall drainage volume during the first 24 hours, transiet laryngeal nerve palsy, permanent laryngeal nerve palsy, transiet hypocalcaemia and permanent hypocalcaemia.</p> <p>Results</p> <p>There are currently 7 RCT on this issue to compare thyroidectomy with UAS versus CT. From the analysis of these studies it was possible to confront 608 cases: 303 undergoing to thyroidectomy with UAS versus 305 that were treated with CT. Actually, it was shown a relevant advantage of cost-effectiveness in patients treated with UAS; there is a statistically significant reduction of the operative duration (weighted mean difference [WMD], -18.74 minutes; 95% confidence interval [CI], (-26.97 to -10.52 minutes) (P = 0.00001), intraoperative blood loss (WMD, -60.10 mL; 95% CI, -117.04 to 3.16 mL) (P = 0.04) and overall drainage volume (WMD, -35.30 mL; 95% CI, -49.24 to 21.36 mL) (P = 0.00001) in the patients underwent thyroidectomy with UAS. Although the analysis showed that the patients who were treated with USA presented more favourable results in incidence of post-operative complications (transient laryngeal nerve palsy: P = 0.11; permanent laryngeal nerve palsy: not estimable; transient hypocalcaemia: P = 0.24; permanent hypocalcaemia: P = 0.45), these data didn't present statistical relevance.</p> <p>Conclusion</p> <p>This meta-analysis shown a relevant advantage only in terms of cost-effectiveness in patients treated with UAS; it is subsequent to statistically significant reduction of operation duration, intraoperative blood loss and of overall drainage volume during the first 24 hours. Although the analysis showed that the patients who were treated with UAS presented more favourable results in incidence of post-operative complications (transiet laryngeal nerve palsy; transiet hypocalcaemia and permanent hypocalcaemia), these data didn't present statistical relevance.</p

    Measurement of the t(t)over-bar production cross section in the dilepton channel in pp collisions at √s=8 TeV

    Get PDF
    The top-antitop quark (t (t) over bar) production cross section is measured in proton-proton collisions at root s = 8 TeV with the CMS experiment at the LHC, using a data sample corresponding to an integrated luminosity of 5.3 fb(-1). The measurement is performed by analysing events with a pair of electrons or muons, or one electron and one muon, and at least two jets, one of which is identified as originating from hadronisation of a bottom quark. The measured cross section is 239 +/- 2 (stat.) +/- 11 (syst.) +/- 6 (lum.) pb, for an assumed top-quark mass of 172.5 GeV, in agreement with the prediction of the standard model

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter

    Compressed representation of a partially defined integer function over multiple arguments

    Get PDF
    In OLAP (OnLine Analitical Processing) data are analysed in an n-dimensional cube. The cube may be represented as a partially defined function over n arguments. Considering that often the function is not defined everywhere, we ask: is there a known way of representing the function or the points in which it is defined, in a more compact manner than the trivial one

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore