1,645 research outputs found
Clinical translation of genetic testing in TTR Amyloidosis. genotype-phenotype correlations, management of asymptomatic carriers and familial screening
Transthyretin (TTR)-related amyloidosis (ATTR) is a heterogeneous disease with different organ involvement depending on the type of TTR infiltration [mutated (vTTR) or wild-type (wtTTR)]. Genetic testing in ATTR is required to define diagnosis and identify asymptomatic at-risk family members. Since new therapies are maximally effective in the early stages of the disease, there is a growing agreement about the need for close monitoring of genotype-positive, phenotype-negative individuals to assure a prompt treatment when minor disease signs are
detected. This review summarizes the complexity of genotype-phenotype correlation and revises the current indications with respect to familiar screening and management of asymptomatic carriers
Influence of shock wave propagation on dielectric barrier discharge plasma actuator performance
Interest in plasma actuators as active flow control devices is growing rapidly due to their lack of mechanical parts, light weight and high response frequency. Although the flow induced by these actuators has received much attention, the effect that the external flow has on the performance of the actuator itself must also be considered, especially the influence of unsteady high-speed flows which are fast becoming a norm in the operating flight envelopes. The primary objective of this study is to examine the characteristics of a dielectric barrier discharge (DBD) plasma actuator when exposed to an unsteady flow generated by a shock tube. This type of flow, which is often used in different studies, contains a range of flow regimes from sudden pressure and density changes to relatively uniform high-speed flow regions. A small circular shock tube is employed along with the schlieren photography technique to visualize the flow. The voltage and current traces of the plasma actuator are monitored throughout, and using the well-established shock tube theory the change in the actuator characteristics are related to the physical processes which occur inside the shock tube. The results show that not only is the shear layer outside of the shock tube affected by the plasma but the passage of the shock front and high-speed flow behind it also greatly influences the properties of the plasma
Study of the 12C + 12C reaction at 62 A MeV for hadrontherapy applications
The largest uncertainty on the physical dose deposition in hadrontherapy is due to ion’s nuclear interaction through the traversed material. Today the simulation codes are not able to reproduce the fragmentation process with the
required precision. To improve the knowledge of 12C fragmentation at intermediate energies we have measured at the Laboratori Nazionali del Sud in Catania production
cross sections, energy spectra and angular distributions of fragments produced in 12C fragmentation on thin 12C target, at 62A MeV
Carbon fragmentation measurements and validation of the GEANT4 nuclear reaction models for hadrontherapy
Nuclear fragmentation measurements are necessary when using heavy-ion beams in hadrontherapy to predict the effects of the ion nuclear interactions within the human body. Moreover, they are also fundamental to validate and improve the Monte Carlo codes for their use in planning tumor treatments. Nowadays, a very limited set of carbon fragmentation cross sections are being measured, and in particular, to our knowledge, no double-differential fragmentation cross sections at intermediate energies are available in the literature. In this work, we have measured the double-differential cross sections and the angular distributions of the secondary fragments produced in the C-12 fragmentation at 62 A MeV on a thin carbon target. The experimental data have been used to benchmark the prediction capability of the GEANT4 Monte Carlo code at intermediate energies, where it was never tested before. In particular, we have compared the experimental data with the predictions of two GEANT4 nuclear reaction models: the Binary Light Ions Cascade and the Quantum Molecular Dynamic. From the comparison, it has been observed that the Binary Light Ions Cascade approximates the angular distributions of the fragment production cross sections better than the Quantum Molecular Dynamic model. However, the discrepancies observed between the experimental data and the Monte Carlo simulations lead to the conclusion that the prediction capability of both models needs to be improved at intermediate energies
The role of sentinel node tumor burden in modeling the prognosis of melanoma patients with positive sentinel node biopsy: an Italian melanoma intergroup study (N = 2,086)
Background The management of melanoma patients with metastatic melanoma in the sentinel nodes (SN) is evolving based on the results of trials questioning the impact of completion lymph node dissection (CLND) and demonstrating the efficacy of new adjuvant treatments. In this landscape, new prognostic tools for fine risk stratification are eagerly sought to optimize the therapeutic path of these patients. Methods A retrospective cohort of 2,086 patients treated with CLND after a positive SN biopsy in thirteen Italian Melanoma Centers was reviewed. Overall survival (OS) was the outcome of interest; included independent variables were the following: age, gender, primary melanoma site, Breslow thickness, ulceration, sentinel node tumor burden (SNTB), number of positive SN, non-sentinel lymph nodes (NSN) status. Univariate and multivariate survival analyses were performed using the Cox proportional hazard regression model. Results The 3-year, 5-year and 10-year OS rates were 79%, 70% and 54%, respectively. At univariate analysis, all variables, except for primary melanoma body site, were found to be statistically significant prognostic factors. Multivariate Cox regression analysis indicated that older age (P < 0.0001), male gender (P = 0.04), increasing Breslow thickness (P < 0.0001), presence of ulceration (P = 0.004), SNTB size (P < 0.0001) and metastatic NSN (P < 0.0001) were independent negative predictors of OS. Conclusion The above results were utilized to build a nomogram in order to ease the practical implementation of our prognostic model, which might improve treatment personalization
Search for New Physics with Jets and Missing Transverse Momentum in pp collisions at sqrt(s) = 7 TeV
A search for new physics is presented based on an event signature of at least
three jets accompanied by large missing transverse momentum, using a data
sample corresponding to an integrated luminosity of 36 inverse picobarns
collected in proton--proton collisions at sqrt(s)=7 TeV with the CMS detector
at the LHC. No excess of events is observed above the expected standard model
backgrounds, which are all estimated from the data. Exclusion limits are
presented for the constrained minimal supersymmetric extension of the standard
model. Cross section limits are also presented using simplified models with new
particles decaying to an undetected particle and one or two jets
Loss of Arc renders the visual cortex impervious to the effects of sensory experience or deprivation
A myriad of mechanisms have been suggested to account for the full richness of visual cortical plasticity. We found that visual cortex lacking Arc is impervious to the effects of deprivation or experience. Using intrinsic signal imaging and chronic visually evoked potential recordings, we found that Arc−/− mice did not exhibit depression of deprived-eye responses or a shift in ocular dominance after brief monocular deprivation. Extended deprivation also failed to elicit a shift in ocular dominance or open-eye potentiation. Moreover, Arc−/− mice lacked stimulus-selective response potentiation. Although Arc−/− mice exhibited normal visual acuity, baseline ocular dominance was abnormal and resembled that observed after dark-rearing. These data suggest that Arc is required for the experience-dependent processes that normally establish and modify synaptic connections in visual cortex.Howard Hughes Medical InstituteNational Science Foundation (U.S.
X-ray emission from the Sombrero galaxy: discrete sources
We present a study of discrete X-ray sources in and around the
bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival
Chandra observations with a total exposure of ~200 ks. With a detection limit
of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30
kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler
et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS
observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray
binaries (LMXBs). We quantify the differential luminosity functions (LFs) for
both the detected GC and field LMXBs, whose power-low indices (~1.1 for the
GC-LF and ~1.6 for field-LF) are consistent with previous studies for
elliptical galaxies. With precise sky positions of the GCs without a detected
X-ray source, we further quantify, through a fluctuation analysis, the GC LF at
fainter luminosities down to 1E35 erg/s. The derived index rules out a
faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent
findings in several elliptical galaxies and the bulge of M31. On the other
hand, the 2-6 keV unresolved emission places a tight constraint on the field
LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101
sources in the halo of Sombrero. The presence of these sources cannot be
interpreted as galactic LMXBs whose spatial distribution empirically follows
the starlight. Their number is also higher than the expected number of cosmic
AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray
surveys. We suggest that either the cosmic X-ray background is unusually high
in the direction of Sombrero, or a distinct population of X-ray sources is
present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
- …