183 research outputs found

    ZOOM or Non-ZOOM? Assessing spinal cord diffusion tensor imaging protocols for multi-centre studies

    Get PDF
    The purpose of this study was to develop and evaluate two spinal cord (SC) diffusion tensor imaging (DTI) protocols, implemented at multiple sites (using scanners from two different manufacturers), one available on any clinical scanner, and one using more advanced options currently available in the research setting, and to use an automated processing method for unbiased quantification. DTI parameters are sensitive to changes in the diseased SC. However, imaging the cord can be technically challenging due to various factors including its small size, patient-related and physiological motion, and field inhomogeneities. Rapid acquisition sequences such as Echo Planar Imaging (EPI) are desirable but may suffer from image distortions. We present a multi-centre comparison of two acquisition protocols implemented on scanners from two different vendors (Siemens and Philips), one using a reduced field-of-view (rFOV) EPI sequence, and one only using options available on standard clinical scanners such as outer volume suppression (OVS). Automatic analysis was performed with the Spinal Cord Toolbox for unbiased and reproducible quantification of DTI metrics in the white matter. Images acquired using the rFOV sequence appear less distorted than those acquired using OVS alone. SC DTI parameter values obtained using both sequences at all sites were consistent with previous measurements made at 3T. For the same scanner manufacturer, DTI parameter inter-site SDs were smaller for the rFOV sequence compared to the OVS sequence. The higher inter-site reproducibility (for the same manufacturer and acquisition details, i.e. ZOOM data acquired at the two Philips sites) of rFOV compared to the OVS sequence supports the idea that making research options such as rFOV more widely available would improve accuracy of measurements obtained in multi-centre clinical trials. Future multi-centre studies should also aim to match the rFOV technique and signal-to-noise ratios in all sequences from different manufacturers/sites in order to avoid any bias in measured DTI parameters and ensure similar sensitivity to pathological changes

    Traumatic and nontraumatic spinal cord injury: pathological insights from neuroimaging

    Get PDF
    Pathophysiological changes in the spinal cord white and grey matter resulting from injury can be observed with MRI techniques. These techniques provide sensitive markers of macrostructural and microstructural tissue integrity, which correlate with histological findings. Spinal cord MRI findings in traumatic spinal cord injury (tSCI) and nontraumatic spinal cord injury — the most common form of which is degenerative cervical myelopathy (DCM) — have provided important insights into the pathophysiological processes taking place not just at the focal injury site but also rostral and caudal to the spinal injury. Although tSCI and DCM have different aetiologies, they show similar degrees of spinal cord pathology remote from the injury site, suggesting the involvement of similar secondary degenerative mechanisms. Advanced quantitative MRI protocols that are sensitive to spinal cord pathology have the potential to improve diagnosis and, more importantly, predict outcomes in patients with tSCI or nontraumatic spinal cord injury. This Review describes the insights into tSCI and DCM that have been revealed by neuroimaging and outlines current activities and future directions for the field

    Evidence of distributed subpial T2* signal changes at 7T in multiple sclerosis : an histogram based approach

    Get PDF
    Subpial lesions are the most frequent type of cortical lesion in multiple sclerosis (MS), and are thought to be closely associated with poor clinical outcome. Neuropathological studies report that subpial lesions may come in two major types: they may appear as circumscribed, focal lesions, or extend across multiple adjacent gyri leading to a phenomenon termed “general subpial demyelination” [1]. The in vivo evaluation of diffuse subpial disease is challenging – signal changes may be subtle, and extend across large regions where signal inhomogeneities due to B1 and RF receive coil non-uniformities become more pronounced. Here, we investigate whether a histogram-based analysis of T2* signal intensity in the cortex, at 7T MRI, can show evidence of distributed subpial cortical changes in patients with MS, as described histopathologically. We hypothesized that this phenomenon would be associated with significantly increased T2* signal intensity in patients compared to age-matched controls.Center Algoritm

    Microscopy-BIDS: An extension to the brain imaging data structure for microscopy data

    Get PDF
    The Brain Imaging Data Structure (BIDS) is a specification for organizing, sharing, and archiving neuroimaging data and metadata in a reusable way. First developed for magnetic resonance imaging (MRI) datasets, the community-led specification evolved rapidly to include other modalities such as magnetoencephalography, positron emission tomography, and quantitative MRI (qMRI). In this work, we present an extension to BIDS for microscopy imaging data, along with example datasets. Microscopy-BIDS supports common imaging methods, including 2D/3D, ex/in vivo, micro-CT, and optical and electron microscopy. Microscopy-BIDS also includes comprehensible metadata definitions for hardware, image acquisition, and sample properties. This extension will facilitate future harmonization efforts in the context of multi-modal, multi-scale imaging such as the characterization of tissue microstructure with qMRI

    Sarcoma granulocĂ­tico multicĂŞntrico como recidiva de leucemia mieloide aguda

    Full text link
    Sarcoma granulocítico (SG) é um tumor sólido extramedular, constituído por células precursoras de granulócitos. É geralmente associado a leucemia mieloide aguda ou raramente a outras desordens mieloproliferativas. O tumor geralmente ocorre precedendo uma leucemia mieloide aguda, durante o seu curso ou após a remissão ter sido alcançada. O prognóstico é pobre e tem como principais modalidades terapêuticas a quimioterapia e a radioterapia. Relata- se um caso de SG multicêntrico, de evolução rápida, com acometimento difuso de pele, mamas, gânglios linfáticos, tecido celular subcutâneo e líquor, em mulher de 45 anos, fora de tratamento para leucemia mieloide aguda e em remissão hematológica há 18 meses. A paciente apresentava dor intensa em membro inferior direito há uma semana e estava em anticoagulação oral há seis meses por trombose venosa profunda neste membro. Diagnosticado o SG, a paciente foi tratada com radioterapia e quimioterapia com boa resposta. Após três meses de seguimento, em vigência do tratamento quimioterápico, evoluiu com recidiva do SG neste membro, associado ao acometimento das mamas e posteriormente do sistema nervoso central, evoluindo para óbito em aplasia e sepses

    The current state-of-the-art of spinal cord imaging: methods.

    Get PDF
    A first-ever spinal cord imaging meeting was sponsored by the International Spinal Research Trust and the Wings for Life Foundation with the aim of identifying the current state-of-the-art of spinal cord imaging, the current greatest challenges, and greatest needs for future development. This meeting was attended by a small group of invited experts spanning all aspects of spinal cord imaging from basic research to clinical practice. The greatest current challenges for spinal cord imaging were identified as arising from the imaging environment itself; difficult imaging environment created by the bone surrounding the spinal canal, physiological motion of the cord and adjacent tissues, and small cross-sectional dimensions of the spinal cord, exacerbated by metallic implants often present in injured patients. Challenges were also identified as a result of a lack of "critical mass" of researchers taking on the development of spinal cord imaging, affecting both the rate of progress in the field, and the demand for equipment and software to manufacturers to produce the necessary tools. Here we define the current state-of-the-art of spinal cord imaging, discuss the underlying theory and challenges, and present the evidence for the current and potential power of these methods. In two review papers (part I and part II), we propose that the challenges can be overcome with advances in methods, improving availability and effectiveness of methods, and linking existing researchers to create the necessary scientific and clinical network to advance the rate of progress and impact of the research

    Mutational profile of TP53 in esophageal squamous cell carcinoma associated with chagasic megaesophagus

    Get PDF
    Chaga's disease is an important communicable neglected disease that is gaining wider attention due to its increasing incidence worldwide. Achalasia due to chagasic megaesophagus (CM), a complication of this disease, is a known-yet, poorly understood-etiological factor for esophageal squamous cell carcinoma (ESCC) development. In this study, we aimed to perform the analysis of TP53 mutations in a series of Brazilian patients with ESCC that developed in the context CM (ESCC/CM), and to compare with the TP53 mutation profile of patients with benign CM and patients with nonchagasic ESCC. Additionally, we intended to correlate the TP53 mutation results with patient's clinical pathological features. By polymerase chain reaction (PCR) followed by direct sequencing of the hotspot regions of TP53 (exon 5 to 8), we found that TP53 mutations were present in 40.6% (13/32) of the ESCC/CM group, 45% (18/40) of the nonchagasic ESCC group, and in only 3% (1/33) of the benign CM group. Missense mutations were the most common in the three groups, yet, the type and mutated exon mutation varied significantly among the groups. Clinically, the groups exhibited distinct features, with both cancer groups (ESCC and ESCC/CM) been significantly associated higher consumption of alcohol and tobacco, older age, worse Karnofsky performance status, poor outcome than the patients with benign CM. No significant association was found between TP53 mutation profile and clinical-pathological features in any of the three groups. We describe first the time the analysis of TP53 mutations in ESCC that developed in the context of CM, and the observed high frequency of mutations, suggest that TP53 also plays an important role in the tumorigenic process of this unexplored etiological condition.Supported by Barretos Cancer Hospital internal research funds (PAIP). Rui M Reis is recipient of a CNPq Produtividade em Pesquisa grantinfo:eu-repo/semantics/publishedVersio

    Spinal cord grey matter segmentation challenge

    Get PDF
    An important image processing step in spinal cord magnetic resonance imaging is the ability to reliably and accurately segment grey and white matter for tissue specific analysis. There are several semi- or fully-automated segmentation methods for cervical cord cross-sectional area measurement with an excellent performance close or equal to the manual segmentation. However, grey matter segmentation is still challenging due to small cross-sectional size and shape, and active research is being conducted by several groups around the world in this field. Therefore a grey matter spinal cord segmentation challenge was organised to test different capabilities of various methods using the same multi-centre and multi-vendor dataset acquired with distinct 3D gradient-echo sequences. This challenge aimed to characterize the state-of-the-art in the field as well as identifying new opportunities for future improvements. Six different spinal cord grey matter segmentation methods developed independently by various research groups across the world and their performance were compared to manual segmentation outcomes, the present gold-standard. All algorithms provided good overall results for detecting the grey matter butterfly, albeit with variable performance in certain quality-of-segmentation metrics. The data have been made publicly available and the challenge web site remains open to new submissions. No modifications were introduced to any of the presented methods as a result of this challenge for the purposes of this publication

    Histological basis of laminar MRI patterns in high resolution images of fixed human auditory cortex

    Get PDF
    Functional magnetic resonance imaging (fMRI) studies of the auditory region of the temporal lobe would benefit from the availability of image contrast that allowed direct identification of the primary auditory cortex, as this region cannot be accurately located using gyral landmarks alone. Previous work has suggested that the primary area can be identified in magnetic resonance (MR) images because of its relatively high myelin content. However, MR images are also affected by the iron content of the tissue and in this study we sought to confirm that different MR image contrasts did correlate with the myelin content in the grey matter and were not primarily affected by iron content as is the case in the primary visual and somatosensory areas. By imaging blocks of fixed post-mortem cortex in a 7 Tesla scanner and then sectioning them for histological staining we sought to assess the relative contribution of myelin and iron to the grey matter contrast in the auditory region. Evaluating the image contrast in T2*-weighted images and quantitative R2* maps showed a reasonably high correlation between the myelin density of the grey matter and the intensity of the MR images. The correlation with T1-weighted phase sensitive inversion recovery (PSIR) images was better than with the previous two image types, and there were clearly differentiated borders between adjacent cortical areas in these images. A significant amount of iron was present in the auditory region, but did not seem to contribute to the laminar pattern of the cortical grey matter in MR images. Similar levels of iron were present in the grey and white matter and although iron was present in fibres within the grey matter, these fibres were fairly uniformly distributed across the cortex. Thus we conclude that T1- and T2*-weighted imaging sequences do demonstrate the relatively high myelin levels that are characteristic of the deep layers in primary auditory cortex and allow it and some of the surrounding areas to be reliably distinguished

    Clinically Feasible Microstructural MRI to Quantify Cervical Spinal Cord Tissue Injury Using DTI, MT, and T2*-Weighted Imaging:Assessment of Normative Data and Reliability

    Get PDF
    Forty healthy subjects underwent T2WI, DTI, magnetization transfer, and T2*WI at 3T in BACKGROUND AND PURPOSE: DTI, magnetization transfer, T2*-weighted imaging, and cross-sectional area can quantify aspects of spinal cord microstructure. However, clinical adoption remains elusive due to complex acquisitions, cumbersome analysis, limited reliability, and wide ranges of normal values. We propose a simple multiparametric protocol with automated analysis and report normative data, analysis of confounding variables, and reliability. MATERIALS AND METHODS: Forty healthy subjects underwent T2WI, DTI, magnetization transfer, and T2*WI at 3T in RESULTS: T2*WI WM/GM showed lower intersubject coefficient of variation (3.5%) compared with magnetization transfer ratio (5.8%), fractional anisotropy (6.0%), and cross-sectional area (12.2%). Linear correction of cross-sectional area with cervical cord length, fractional anisotropy with age, and magnetization transfer ratio with age and height led to decreased coefficients of variation (4.8%, 5.4%, and 10.2%, respectively). Acceptable reliability was achieved for all metrics/levels (test-retest coefficient of variation <5%), with T2*WI WM/GM comparing favorably with fractional anisotropy and magnetization transfer ratio. DTI with and without cardiac triggering showed no significant differences for fractional anisotropy and test-retest coefficient of variation. CONCLUSIONS: Reliable multiparametric assessment of spinal cord microstructure is possible by using clinically suitable methods. These results establish normalization procedures and pave the way for clinical studies, with the potential for improving diagnostics, objectively monitoring disease progression, and predicting outcomes in spinal pathologies
    • …
    corecore