498 research outputs found

    Risk factors of post renal transplant anaemia among Sudanese patients, a study in three renal transplant centres

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is a relative lack of recent information about late post kidney transplantation anaemia (PTA), especially in the developing countries; data are scarce about the prevalence and risk factors of PTA. Sudan was a leading country in Africa and Arab world in kidney transplantation. The first kidney transplantation in Sudan was in 1973.</p> <p>Methods</p> <p>This is a cross-sectional hospital analytic study enrolling all kidney transplanted recipients following in the transplant referral clinics at Ahmed Gassim, Selma and Ibn Sina Hospitals, Khartoum/Sudan, in the period from 1/8/2010 to 1/9/2010, clinical and laboratory data were obtained from 114 patients, anaemia was defined as Hb levels of < 13 g/dl for male patients and < 12 g/dl for female patients, exclusion criteria were pregnancy, below 18 years old patients, multiple organ transplantation, and patients with less than one year from the transplantation.</p> <p>Results</p> <p>The study showed that 39.5% of the patients were anaemic. Univariate analysis showed that late PTA is significantly associated with not using Erythropoietin (EPO) in the pre-transplant period (p = < 0.001), history of rejection (p = 0.003), longer time from transplantation (p = 0.015), and eGFR (p < 0.0001). Multivariate analysis showed that eGFR (p = < 0.001) and not use of EPO in the pre transplant period (p < 0.001) are strong predictors of PTA. The use of Angiotensin converting enzyme inhibitors/Angiotensin receptors blockers (ACEI/ARB), immunosuppressive treatments, presence or absence of co-morbidities, donor type and donor age are not significantly associated with late PTA.</p> <p>Conclusion</p> <p>The study concluded that late PTA is common and under recognized. Risk factors for late PTA include renal dysfunction, history of rejection, longer duration of transplantation and not using EPO in the pre-transplant period. Renal dysfunction and not using EPO in the pre-transplant period are major predictors of late PTA.</p

    Survival in Southern European patients waitlisted for kidney transplant after graft failure: A competing risk analysis

    Full text link
    Background Whether patients waitlisted for a second transplant after failure of a previous kidney graft have higher mortality than transplant-näive waitlisted patients is uncertain. Methods We assessed the relationship between a failed transplant and mortality in 3851 adult KT candidates, listed between 1984–2012, using a competing risk analysis in the total population and in a propensity score-matched cohort. Mortality was also modeled by inverse probability weighting (IPTW) competing risk regression. Results At waitlist entry 225 (5.8%) patients had experienced transplant failure. All-cause mortality was higher in the post-graft failure group (16% vs. 11%; P = 0.033). Most deaths occurred within three years after listing. Cardiovascular disease was the leading cause of death (25.3%), followed by infections (19.3%). Multivariate competing risk regression showed that prior transplant failure was associated with a 1.5-fold increased risk of mortality (95% confidence interval [CI], 1.01–2.2). After propensity score matching (1:5), the competing risk regression model revealed a subhazard ratio (SHR) of 1.6 (95% CI, 1.01–2.5). A similar mortality risk was observed after the IPTW analysis (SHR, 1.7; 95% CI, 1.1–2.6). Conclusions Previous transplant failure is associated with increased mortality among KT candidates after relisting. This information is important in daily clinical practice when assessing relisted patients for a retransplant.This study was supported in part by the Spanish Ministry of Economy and Competitiveness (MINECO) (grant ICI14/00016) from the Instituto de Salud Carlos III co-funded by the Fondo Europeo de Desarrollo Regional±FEDER, RETICS (REDINREN RD16/0009/0006, RD16/0009/0031

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Serum osteoprotegerin is associated with pulse pressure in kidney transplant recipients

    Get PDF
    Pulse pressure (PP) reflects increased large artery stiffness, which is caused, in part, by arterial calcification in patients with chronic kidney disease. PP has been shown to predict both cardiovascular and cerebrovascular events in various patient populations, including kidney transplant (KTX) recipients. Osteoprotegerin (OPG) is a marker and regulator of arterial calcification, and it is related to cardiovascular survival in hemodialysis patients. Here we tested the hypothesis that OPG is associated with increased pulse pressure. We cross-sectionally analyzed the association between serum OPG and PP in a prevalent cohort of 969 KTX patients (mean age: 51 +/- 13 years, 57% male, 21% diabetics, mean eGFR 51 +/- 20 ml/min/1.73 m2). Independent associations were tested in a linear regression model adjusted for multiple covariables. PP was positively correlated with serum OPG (rho = 0.284, p < 0.001). Additionally, a positive correlation was seen between PP versus age (r = 0.358, p < 0.001), the Charlson Comorbidity Index (r = 0.232, p < 0.001), serum glucose (r = 0.172, p < 0.001), BMI (r = 0.133, p = 0.001) and serum cholesterol (r = 0.094, p = 0.003). PP was negatively correlated with serum Ca, albumin and eGFR. The association between PP and OPG remained significant after adjusting for multiple potentially relevant covariables (beta = 0.143, p < 0.001). We conclude that serum OPG is independently associated with pulse pressure in kidney transplant recipients

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter
    corecore